Human-Robot Interaction Strategies for Walker-Assisted Locomotion
Neurological and age-related diseases affect human mobility at different levels causing partial or total loss of such faculty. There is a significant need to improve safe and efficient ambulation of patients with gait impairments. In this context, walkers present important benefits for human mobility, improving balance and reducing the load on their lower limbs. Most importantly, walkers induce the use of patients residual mobility capacities in different environments. In the field of robotic technologies for gait assistance,
a new category of walkers has emerged, integrating robotic technology, electronics and mechanics. Such devices are known as robotic walkers, intelligent walkers or smart walkers One of the specific and important common aspects to the field of assistive technologies and rehabilitation robotics is the intrinsic interaction between the human and the robot.
In this thesis, the concept of Human-Robot Interaction (HRI) for human locomotion assistance is explored. This interaction is composed of two interdependent components.
On the one hand, the key role of a robot in a Physical HRI (pHRI) is the generation of supplementary forces to empower the human locomotion. This involves a net flux of power between both actors. On the other hand, one of the crucial roles of a Cognitive HRI (cHRI) is to make the human aware of the possibilities of the robot while allowing him to maintain control of the robot at all times.
This doctoral thesis presents a new multimodal human-robot interface for testing and validating control strategies applied to a robotic walkers for assisting human mobility and gait rehabilitation. This interface extracts navigation intentions from a novel sensor fusion method that combines: (i) a Laser Range Finder (LRF) sensor to estimate the users legs kinematics, (ii) wearable Inertial Measurement Unit (IMU) sensors to capture the human and robot orientations and (iii) force sensors measure the physical interaction
between the humans upper limbs and the robotic walker.
Two close control loops were developed to naturally adapt the walker position and to perform body weight support strategies. First, a force interaction controller generates velocity outputs to the walker based on the upper-limbs physical interaction. Second, a inverse kinematic controller keeps the walker within a desired position to the human improving such interaction.
The proposed control strategies are suitable for natural human-robot interaction as shown during the experimental validation. Moreover, methods for sensor fusion to estimate the control inputs were presented and validated. In the experimental studies, the parameters estimation was precise and unbiased. It also showed repeatability when speed changes and continuous turns were performed
Empowering and assisting natural human mobility: The simbiosis walker
This paper presents the complete development of the Simbiosis Smart Walker. The device is equipped with a set of sensor subsystems to acquire user-machine interaction forces and the temporal evolution of user's feet during gait. The authors present an adaptive filtering technique used for the identification and separation of different components found on the human-machine interaction forces. This technique allowed isolating the components related with the navigational commands and developing a Fuzzy logic controller to guide the device. The Smart Walker was clinically validated at the Spinal Cord Injury Hospital of Toledo - Spain, presenting great acceptability by spinal chord injury patients and clinical staf
A functional electrical stimulation system for human walking inspired by reflexive control principles
This study presents an innovative multichannel functional electrical stimulation gait-assist system which employs a well-established purely reflexive control algorithm, previously tested in a series of bipedal walking robots. In these robots, ground contact information was used to activate motors in the legs, generating a gait cycle similar to that of humans. Rather than developing a sophisticated closed-loop functional electrical stimulation control strategy for stepping, we have instead utilised our simple reflexive model where muscle activation is induced through transfer functions which translate sensory signals, predominantly ground contact information, into motor actions. The functionality of the functional electrical stimulation system was tested by analysis of the gait function of seven healthy volunteers during functional electrical stimulation–assisted treadmill walking compared to unassisted walking. The results demonstrated that the system was successful in synchronising muscle activation throughout the gait cycle and was able to promote functional hip and ankle movements. Overall, the study demonstrates the potential of human-inspired robotic systems in the design of assistive devices for bipedal walking
Assistive mobility devices focusing on smart walkers : classification and review
In an aging society it is extremely important to develop devices, which can support and aid the elderly in their daily life. This demands means and tools that extend independent living and promote improved health.
Thus, the goal of this article is to review the state of the art in the robotic technology for mobility assistive devices for people with mobility disabilities. The important role that robotics can play in mobility assistive devices is presented, as well as the identification and survey of mobility assistive devices subsystems with a particular focus on the walkers technology. The advances in the walkers’ field have been enormous and have shown a great potential on helping people with mobility disabilities. Thus it is presented a review of the available literature of walkers and are discussed major advances that have been made and limitations to be overcome
Locomotor training through a novel robotic platform for gait rehabilitation in pediatric population: short report
[Background]
Cerebral Palsy (CP) is a disorder of posture and movement due to a defect in the immature brain. The use of robotic devices as alternative treatment to improve the gait function in patients with CP has increased. Nevertheless, current gait trainers are focused on controlling complete joint trajectories, avoiding postural control and the adaptation of the therapy to a specific patient. This paper presents the applicability of a new robotic platform called CPWalker in children with spastic diplegia.[Findings]
CPWalker consists of a smart walker with body weight and autonomous locomotion support and an exoskeleton for joint motion support. Likewise, CPWalker enables strategies to improve postural control during walking. The integrated robotic platform provides means for testing novel gait rehabilitation therapies in subjects with CP and similar motor disorders. Patient-tailored therapies were programmed in the device for its evaluation in three children with spastic diplegia for 5 weeks.
After ten sessions of personalized training with CPWalker, the children improved the mean velocity (51.94 ± 41.97 %), cadence (29.19 ± 33.36 %) and step length (26.49 ± 19.58 %) in each leg. Post-3D gait assessments provided kinematic outcomes closer to normal values than Pre-3D assessments.[Conclusions]
The results show the potential of the novel robotic platform to serve as a rehabilitation tool. The autonomous locomotion and impedance control enhanced the children’s participation during therapies. Moreover, participants’ postural control was substantially improved, which indicates the usefulness of the approach based on promoting the patient’s trunk control while the locomotion therapy is executed. Although results are promising, further studies with bigger sample size are required.The work presented in this paper has been carried out with the financial support from the Ministerio de Economía y Competitividad of Spain, under Contract DPI2012-39133-C03-01.Peer reviewe
Bipedial Locomotion Up Sandy Slopes: Systematic Experiments Using Zero Moment Point Methods
Bipedal robotic locomotion in granular media presents a unique set of challenges at the intersection of granular physics and robotic locomotion. In this paper, we perform a systematic experimental study in which biped robotic gaits for traversing a sandy slope are empirically designed using Zero Moment Point (ZMP) methods. We are able to implement gaits that allow our 7 degree-of-freedom planar walking robot to ascend slopes with inclines up to 10°. Firstly, we identify a given set of kinematic parameters that meet the ZMP stability criterion for uphill walking at a given angle. We then find that further relating the step lengths and center of mass heights to specific slope angles through an interpolated fit allows for significantly improved success rates when ascending a sandy slope. Our results provide increased insight into the design, sensitivity and robustness of gaits on granular material, and the kinematic changes necessary for stable locomotion on complex media
Automatic Setting Procedure for Exoskeleton-Assisted Overground Gait: Proof of Concept on Stroke Population
Stroke-related locomotor impairments are often associated with abnormal timing and intensity of recruitment of the affected and non-affected lower limb muscles. Restoring the proper lower limbs muscles activation is a key factor to facilitate recovery of gait capacity and performance, and to reduce maladaptive plasticity. Ekso is a wearable powered exoskeleton robot able to support over-ground gait training. The user controls the exoskeleton by triggering each single step during the gait cycle. The fine-tuning of the exoskeleton control system is crucial-it is set according to the residual functional abilities of the patient, and it needs to ensure lower limbs powered gait to be the most physiological as possible. This work focuses on the definition of an automatic calibration procedure able to detect the best Ekso setting for each patient. EMG activity has been recorded from Tibialis Anterior, Soleus, Rectus Femoris, and Semitendinosus muscles in a group of 7 healthy controls and 13 neurological patients. EMG signals have been processed so to obtain muscles activation patterns. The mean muscular activation pattern derived from the controls cohort has been set as reference. The developed automatic calibration procedure requires the patient to perform overground walking trials supported by the exoskeleton while changing parameters setting. The Gait Metric index is calculated for each trial, where the closer the performance is to the normative muscular activation pattern, in terms of both relative amplitude and timing, the higher the Gait Metric index is. The trial with the best Gait Metric index corresponds to the best parameters set. It has to be noted that the automatic computational calibration procedure is based on the same number of overground walking trials, and the same experimental set-up as in the current manual calibration procedure. The proposed approach allows supporting the rehabilitation team in the setting procedure. It has been demonstrated to be robust, and to be in agreement with the current gold standard (i.e., manual calibration performed by an expert engineer). The use of a graphical user interface is a promising tool for the effective use of an automatic procedure in a clinical context
- …