28,013 research outputs found

    Distributed machining control and monitoring using smart sensors/actuators

    Get PDF
    The study of smart sensors and actuators led, during the past few years, to the development of facilities which improve traditional sensors and actuators in a necessary way to automate production systems. In an other context, many studies are carried out aiming at defining a decisional structure for production activity control and the increasing need of reactivity leads to the autonomization of decisional levels close to the operational system. We suggest in this paper to study the natural convergence between these two approaches and we propose an integration architecture dealing with machine tool and machining control that enables the exploitation of distributed smart sensors and actuators in the decisional system

    Architecture of a network-in-the-Loop environment for characterizing AC power system behavior

    Get PDF
    This paper describes the method by which a large hardware-in-the-loop environment has been realized for three-phase ac power systems. The environment allows an entire laboratory power-network topology (generators, loads, controls, protection devices, and switches) to be placed in the loop of a large power-network simulation. The system is realized by using a realtime power-network simulator, which interacts with the hardware via the indirect control of a large synchronous generator and by measuring currents flowing from its terminals. These measured currents are injected into the simulation via current sources to close the loop. This paper describes the system architecture and, most importantly, the calibration methodologies which have been developed to overcome measurement and loop latencies. In particular, a new "phase advance" calibration removes the requirement to add unwanted components into the simulated network to compensate for loop delay. The results of early commissioning experiments are demonstrated. The present system performance limits under transient conditions (approximately 0.25 Hz/s and 30 V/s to contain peak phase-and voltage-tracking errors within 5. and 1%) are defined mainly by the controllability of the synchronous generator

    Automatic control of a liquid nitrogen cooled, closed-circuit, cryogenic pressure tunnel

    Get PDF
    The control system design, performance analysis, microprocesser based controller software development, and specifications for the Transonic Cryogenic Tunnel (TCT) are discussed. The control laws for the single-input single-output controllers were tested on the TCT simulator, and successfully demonstrated on the TCT

    Autonomous Driving Platform Performance Analysis

    Get PDF
    Through data analysis of various plots and figures it will be possible to determine the best control parameters to get the best performance out of the autonomous driving platform. This data, presented in this thesis, will show quantitatively what the best control strategies are through comparison of different versions of the platform

    Development and flight evaluation of active controls in the L-1011

    Get PDF
    Active controls in the Lockheed L-1011 for increased energy efficiency are discussed. Active wing load alleviation for extended span, increased aspect ratio, and active stability augmentation with a smaller tail for reduced drag and weight are among the topics considered. Flight tests of active wing load alleviation on the baseline aircraft and moving-base piloted simulation developing criteria for stability augmentation are described

    Effects of Transport Delays of Manual Control System Performance

    Get PDF
    Throughput or transport delays in manual control systems can cause degraded performance and lead to potentially unstable operation. With the expanding use of digital processors, throughput delays can occur in manual control systems in a variety of ways such as in digital flight control systems in real aircraft, and in equation of motion computers and computer generated images in simulators. Research has shown the degrading effect of throughput delays on subjective opinion and system performance and dynamic response. A generic manual control system model is used to provide a relatively simple analysis of and explanation for the effects of various types of delays. The consequence of throughput delays of some simple system architectures is also discussed

    Development and flight evaluation of an augmented stability active controls concept: Executive summary

    Get PDF
    A pitch active control system (PACS) was developed and flight tested on a wide body jet transport (L-1011) with a flying horizontal stabilizer. Two dual channel digital computers and the associated software provide command signals to a dual channel series servo which controls the stabilizer power actuators. Input sensor signals to the computer are pitch rate, column trim position, and dynamic pressure. Control laws are given for the PACS and the system architecture is defined. Discussions are given regarding piloted flight simulation and vehicle system simulation and vehicle system simulation tests that are performed to verify control laws and system operation prior to installation on the aircraft. Modifications to the basic aircraft included installation of the PACS, addition of a c.g. management system to provide a c.g. range from 25 to 39% mac, and downrigging of the geared elevator to provide the required nose down control authority for aft c.g. flight test conditions. Three pilots used the Cooper-Harper Rating Scale to judge flying qualities of the aircraft with PACS on and off. The handling qualities with the c.g. at 39% mac (41% stability margin) and PACS operating were judged to be as good as the handling qualities with the c.g. at 25% mac (+15% stability margin) and PACS off

    Feedback control ideas for call center staffing

    Get PDF
    European Control Conference 2009 • Budapest, Hungary, August 23–26, 2009Call centers are nowadays a widespread solution to deal with customer support and as platform for different kind of business. Call center staffing is crucial to provide adequate service levels at acceptable costs. The task is usually accomplished using heuristics with the help of a human experts or with some static offline optimization based on operations research. Simulators based on queue theory are in some cases also used. The aim of the paper is to show that call center staffing can be posed as a feedback control problem with the advantage of getting a higher level of automation, and a wealth of results from control theory that can help to obtain the best possible staffing. In the paper the authors briefly describe the working procedures of call centers and how the staffing is usually made. They propose a feedback controller that it is used with a call center simulator. The results show that good call center staffing can be obtained even with a not very sophisticated controller

    Energy efficiency and integration of urban electrical transport systems: EVS and metro-trains of two real European lines

    Get PDF
    Transport is a main source of pollutants in cities, where air quality is a major concern. New transport technologies, such as electric vehicles, and public transport modalities, such as urban railways, have arisen as solutions to this important problem. One of the main difficulties for the adoption of electric vehicles by consumers is the scarcity of a suitable charging infrastructure. The use of the railway power supplies to charge electric vehicle batteries could facilitate the deployment of charging infrastructure in cities. It would reduce the cost because of the use of an existing installation. Furthermore, electric vehicles can use braking energy from trains that was previously wasted in rheostats. This paper presents the results of a collaboration between research teams from University of Rome Sapienza and Comillas Pontifical University. In this work, two real European cases are studied: an Italian metro line and a Spanish metro line. The energy performance of these metro lines and their capacity to charge electric vehicles have been studied by means of detailed simulation tools. Their results have shown that the use of regenerated energy is 98% for short interval of trains in both cases. However, the use of regenerated energy decreases as the train intervals grow. In a daily operation, an important amount of regenerated energy is wasted in the Italian and Spanish case. Using this energy, a significant number of electric vehicles could be charged every day