721 research outputs found

    An On-line Diagnostic Method for Open-circuit Switch Faults in NPC Multilevel Converters

    Get PDF
    On-line condition monitoring is of paramount importance for multilevel converters used in safety-critical applications. A novel on-line diagnostic method for detecting open-circuit switch faults in neutral-point-clamped (NPC) multilevel converters is introduced in this paper. The principle of this method is based on monitoring the abnormal variation of the dc-bus neutral-point current in combination with the existing information on instantaneous switching states and phase currents. Advantages of this method include simpler implementation and faster detection speed compared to other existing diagnostic methods in the literature. In this method, only one additional current sensor is required for measuring the dc-bus neutral-point current, therefore the implementation cost is low. Simulation and experimental results based on a lab-scale 50 kVA adjustable speed drive (ASD) with a three-level NPC inverter validate the efficacy of this novel diagnostic method

    Advanced Silicon Carbide Based Fault-Tolerant Multilevel Converters

    Get PDF
    The number of safety-critical loads in electric power areas have been increasing drastically in the last two decades. These loads include the emerging more-electric aircraft (MEA), uninterruptible power supplies (UPS), high-power medical instruments, electric and hybrid electric vehicles (EV/HEV) and ships for military use, electric space rovers for space exploration and the like. This dissertation introduces two novel fault-tolerant three-level power converter topologies, named advanced three-level active neutral point clamped converter (A3L-ANPC) and advanced three-level active T-Type (A3L-ATT) converter. The goal of these converters is to increase the reliability of multilevel power converters used in safety-critical applications.These new fault-tolerant multilevel power converters are derived from the conventional ANPC and T-Type converter topologies. The topologies has significantly improved the fault-tolerant capability under any open circuit or certain short-circuit faults in the power semiconductor devices. In addition, under healthy conditions, the redundant phase leg can be utilized to share overload current with other main legs, which enhances the overload capability of the converter. The conduction losses in the power devices can be reduced by sharing the load current with the redundant leg. Moreover, unlike other existing fault-tolerant power converters in the literature, full output voltages can be always obtained during fault-tolerant operation. Experimental prototypes of both the A3L-ANPC and A3L-ATT converters were built based on Silicon Carbide (SiC) MOSFETs. Experimental results confirmed the anticipated performance of the novel three-level converter topologies.SiC MOSFET technology is at the forefront of significant advances in electric power conversion. SiC MOSFETs switch significantly faster than the conventional Silicon counterparts resulting in power converters with higher efficiency and increased switching frequencies. Low switching losses are one of the key characteristics of SiC technology. In this dissertation, hard and soft switching losses of a high power SiC MOSFET module are measured and characterized at different voltage and current operating points to determine the maximum operating frequency of the module. The purpose of characterizing the SiC MOSFET module is to determine the feasibility of very high frequency (200kHz-1MHz) power conversion which may not be possible to be implemented in the conventional Silicon based high power conversion. The results show that higher switching frequencies are achievable with soft switching techniques in high power converters

    Health Condition Monitoring and Fault-Tolerant Operation of Adjustable Speed Drives

    Get PDF
    Adjustable speed drives (ASDs) have been extensively used in industrial applications over the past few decades because of their benefits of energy saving and control flexibilities. However, the wider penetration of ASD systems into industrial applications is hindered by the lack of health monitoring and fault-tolerant operation techniques, especially in safety-critical applications. In this dissertation, a comprehensive portfolio of health condition monitoring and fault-tolerant operation strategies is developed and implemented for multilevel neutral-point-clamped (NPC) power converters in ASDs. Simulations and experiments show that these techniques can improve power cycling lifetime of power transistors, on-line diagnosis of switch faults, and fault-tolerant capabilities.The first contribution of this dissertation is the development of a lifetime improvement Pulse Width Modulation (PWM) method which can significantly extend the power cycling lifetime of Insulated Gate Bipolar Transistors (IGBTs) in NPC inverters operating at low frequencies. This PWM method is achieved by injecting a zero-sequence signal with a frequency higher than that of the IGBT junction-to-case thermal time constants. This, in turn, lowers IGBT junction temperatures at low output frequencies. Thermal models, simulation and experimental verifications are carried out to confirm the effectiveness of this PWM method. As a second contribution of this dissertation, a novel on-line diagnostic method is developed for electronic switch faults in power converters. Targeted at three-level NPC converters, this diagnostic method can diagnose any IGBT faults by utilizing the information on the dc-bus neutral-point current and switching states. This diagnostic method only requires one additional current sensor for sensing the neutral-point current. Simulation and experimental results verified the efficacy of this diagnostic method.The third contribution consists of the development and implementation of a fault-tolerant topology for T-Type NPC power converters. In this fault-tolerant topology, one additional phase leg is added to the original T-Type NPC converter. In addition to providing a fault-tolerant solution to certain switch faults in the converter, this fault-tolerant topology can share the overload current with the original phase legs, thus increasing the overload capabilities of the power converters. A lab-scale 30-kVA ASD based on this proposed topology is implemented and the experimental results verified its benefits

    Design Tools for Submersible Converter

    Get PDF

    Modular Battery Systems for Electric Vehicles based on Multilevel Inverter Topologies - Opportunities and Challenges

    Get PDF
    Modular battery systems based on multilevel inverter (MLI) topologies can possibly overcome some shortcomings of two-level inverters when used for vehicle propulsion. The results presented in this thesis aim to point out the advantages and disadvantages, as well as the technical challenges, of modular vehicle battery systems based on MLIs in comparison to a conventional, two-level IGBT inverter drivetrain. The considered key aspects for this comparative investigation are the drive cycle efficiency, the inverter cost, the fault tolerance capability of the drivetrain and the conducted electromagnetic emissions. Extensive experiments have been performed to support the results and conclusions.In this work, it is shown that the simulated drive cycle efficiency of different low-voltage-MOSFET-based, cascaded seven-level inverter types is improved in comparison to a similarly rated, two-level IGBT inverter drivetrain. For example, the simulated WLTP drive cycle efficiency of a cascaded double-H-bridge (CDHB) inverter drivetrain in comparison to a two-level IGBT inverter, when used in a small passenger car, is increased from 94.24% to 95.04%, considering the inverter and the ohmic battery losses. In contrast, the obtained efficiency of a similar rated seven-level cascaded H-bridge (CHB) drivetrain is almost equal to that of the two-level inverter drivetrain, but with the help of a hybrid modulation technique, utilizing fundamental selective harmonic elimination at lower speeds, it could be improved to 94.85%. In addition, the CDHB and CHB inverters’ cost, in comparison to the two-level inverter, is reduced from 342€ to 202€ and 121€, respectively. Furthermore, based on a simple three-level inverter with a dual battery pack, it is shown that MLIs inherently allow for a fault tolerant operation. It is explained how the drivetrain of a neutral point clamped (NPC) inverter can be operated under a fault condition, so that the vehicle can drive with a limited maximum power to the next service station, referred to as limp home mode. Especially, the detection and localization of open circuit faults has been investigated and verified through simulations and experiments.Moreover, it is explained how to measure the conducted emissions of an NPC inverter with a dual battery pack according to the governing standard, CISPR 25, because the additional neutral point connection forms a peculiar three-wire DC source. To separate the measured noise spectra into CM, line-DM and phase-DMquantities, two hardware separators based on HF transformers are developed and utilized. It is shown that the CM noise is dominant. Furthermore, the CM noise is reduced by 3dB to 6dB when operating the inverter with three-level instead of two-level modulation

    Real-Time Machine Learning Based Open Switch Fault Detection and Isolation for Multilevel Multiphase Drives

    Get PDF
    Due to the rapid proliferation interest of the multiphase machines and their combination with multilevel inverters technology, the demand for high reliability and resilient in the multiphase multilevel drives is increased. High reliability can be achieved by deploying systematic preventive real-time monitoring, robust control, and efficient fault diagnosis strategies. Fault diagnosis, as an indispensable methodology to preserve the seamless post-fault operation, is carried out in consecutive steps; monitoring the observable signals to generate the residuals, evaluating the observations to make a binary decision if any abnormality has occurred, and identifying the characteristics of the abnormalities to locate and isolate the failed components. It is followed by applying an appropriate reconfiguration strategy to ensure that the system can tolerate the failure. The primary focus of presented dissertation was to address employing computational and machine learning techniques to construct a proficient fault diagnosis scheme in multilevel multiphase drives. First, the data-driven nonlinear model identification/prediction methods are used to form a hybrid fault detection framework, which combines module-level and system-level methods in power converters, to enhance the performance and obtain a rapid real-time detection. Applying suggested nonlinear model predictors along with different systems (conventional two-level inverter and three-level neutral point clamped inverter) result in reducing the detection time to 1% of stator current fundamental period without deploying component-level monitoring equipment. Further, two methods using semi-supervised learning and analytical data mining concepts are presented to isolate the failed component. The semi-supervised fuzzy algorithm is engaged in building the clustering model because the deficient labeled datasets (prior knowledge of the system) leads to degraded performance in supervised clustering. Also, an analytical data mining procedure is presented based on data interpretability that yields two criteria to isolate the failure. A key part of this work also dealt with the discrimination between the post-fault characteristics, which are supposed to carry the data reflecting the fault influence, and the output responses, which are compensated by controllers under closed-loop control strategy. The performance of all designed schemes is evaluated through experiments

    A comprehensive review on modular multilevel converters, submodule topologies, and modulation techniques

    Get PDF
    The concept of the modular multilevel converter (MLC) has been raising interest in research in order to improve their performance and applicability. The potential of an MLC is enormous, with a great focus on medium- and high-voltage applications, such as solar photovoltaic and wind farms, electrified railway systems, or power distribution systems. This concept makes it possible to overcome the limitation of the semiconductors blocking voltages, presenting advantageous characteristics. However, the complexity of implementation and control presents added challenges. Thus, this paper aims to contribute with a critical and comparative analysis of the state-of-the-art aspects of this concept in order to maximize its potential. In this paper, different power electronics converter topologies that can be integrated into the MLC concept are presented, highlighting the advantages and disadvantages of each topology. Nevertheless, different modulation techniques used in an MLC are also presented and analyzed. Computational simulations of all the modulation techniques under analysis were developed, based on four cascaded full-bridge topologies. Considering the simulation results, a comparative analysis was possible to make regarding the symmetry of the synthesized waveforms, the harmonic content, and the power distribution in each submodule constituting the MLC.This work has been supported by FCT—Fundação para a Ciência e Tecnologia, within the R&D Units Project Scope UIDB/00319/2020. Mr. Luis A. M. Barros is supported by the doctoral scholarship PD/BD/143006/2018, granted by the Portuguese FCT foundation

    Enhanced Voltage-Sourced Inverters for Large-Scale Grid-Connected Photovoltaic Systems

    Get PDF
    This thesis is mainly focused on (i) modeling of large-scale PV systems in order to study the factors that influence the capacity, efficiency, power quality and safety in connection with the power grid and (ii) proposing system- and circuit-level solutions and control strategies/techniques to improve the aforementioned factors. To that end, a model for PV array is developed to study the mismatch power loss in different PV array interconnection methods, especially during the partial shading condition. Further, a two-MPPT structure is proposed to reduce the mismatch power loss in centrally structured PV systems. Then, a single-stage VSC-based system is proposed to utilize the two-MPPT structure for better efficiency. The proposed system also doubles the DC-link voltage while respecting the safety standards, which in turn, increases the capacity and the efficiency of the central inverter. To further improve capacity and efficiency, a two-stage system is proposed in which the variable MPP voltage of smaller sub-arrays are regulated, by dedicated DC-DC boost converters, at the inverter DC-side terminals. This lets the inverter use the full DC voltage permissible rating and reduces the ohmic loss in DC and AC wirings and in the transformer. The system employs a three-level NPC inverter which generates output with better power quality, facilitates the adoption of two-MPPT structure, and permits utilizing low-voltage (half-rated) switches. The system also promotes the modular/distributed structure which improves the efficiency under partial shading and enables the possibility of utilizing PV modules of different types, ratings, and alignments. Finally, a mitigation technique is proposed in the inverter and grid-interface structures to prevent formation of damaging temporary overvoltages, which sometimes are produced in power systems by distributed generations including PV. The technique utilizes a fourleg inverter connected to a grid through a Y/YG isolation transformer. The effectiveness of the proposed techniques and control strategies are demonstrated through time-domain simulation studies conducted in the PSCAD/EMTDC software environment
    • …
    corecore