1,985 research outputs found

    Highly efficient impulse-radio ultra-wideband cavity-backed slot antenna in stacked air-filled substrate integrated waveguide technology

    Get PDF
    An impulse-radio ultra-wideband (IR-UWB) cavity-backed slot antenna covering the [5.9803; 6.9989] GHz frequency band of the IEEE 802.15.4a-2011 standard is designed and implemented in an air-filled substrate integrated waveguide (AFSIW) technology for localization applications with an accuracy of at least 3 cm. By relying on both frequency and time-domain optimization, the antenna achieves excellent IR-UWB characteristics. In free-space conditions, an impedance bandwidth of 1.92 GHz (or 29.4%), a total efficiency higher than 89%, a front-to-back ratio of at least 12.1 dB, and a gain higher than 6.3 dBi are measured in the frequency domain. Furthermore, a system fidelity factor larger than 98% and a relative group delay smaller than 100 ps are measured in the time domain within the 3 dB beamwidth of the antenna. As a result, the measured time-of-arrival of a transmitted Gaussian pulse, for different angles of arrival, exhibits variations smaller than 100 ps, corresponding to a maximum distance estimation error of 3 cm. Additionally, the antenna is validated in a real-life worst-case deployment scenario, showing that its characteristics remain stable in a large variety of deployment scenarios. Finally, the difference in frequency-and time-domain performance is studied between the antenna implemented in AFSIW and in dielectric filled substrate integrated waveguide (DFSIW) technology. We conclude that DFSIW technology is less suitable for the envisaged precision IR-UWB localization application

    Experimental study of on-body radio channel performance of a compact ultra wideband antenna

    Get PDF
    In this paper, on-body radio channel performance of a compact ultra wideband (UWB) antenna is investigated for body-centric wireless communications. Measurement campaigns were first done in the chamber and then repeated in an indoor environment for comparison. The path loss parameter for eight different on-body radio channels has been characterized and analyzed. In addition, the path loss was modeled as a function of distance for 34 different receiver locations for propagation along the front part of the body. Results and analysis show that, compared with anechoic chamber, a reduction of 16.34% path loss exponent is noticed in indoor environment. The antenna shows very good on-body radio channel performance and will be a suitable candidate for future efficient and reliable body-centric wireless communications

    Novel small-size directional antenna for UWB WBAN/WPAN applications

    Get PDF

    Foldable all-textile cavity-backed slot antennas for personal UWB localization

    Get PDF
    An all-textile multimoded cavity-backed slot antenna has been designed and fabricated for body-worn impulse radio ultra-wideband (IR-UWB) operation in the 3,744-4,742.4 MHz frequency band, thereby covering Channels 2 and 3 of the IEEE 802.15.4a standard. Its light weight, mechanical flexibility, and small footprint of 35 mm x 56 mm facilitate integration into textile for radio communication equipment for first aid responders, personal locator beacons, and equipment for localization and medical monitoring of children or the elderly. The antenna features a stable radiation pattern and reflection coefficient in diverse operating conditions such as in free space, when subject to diverse bending radii and when deployed on the torso or upper right arm of a test person. The high isolation toward the wearer's body originates from the antenna's hemispherical radiation pattern with a -3 dB beamwidth of 120 degrees and a front-to-back ratio higher than 11 dB over the entire band. Moreover, the antenna exhibits a measured maximum gain higher than 6.3 dBi and a radiation efficiency over 75%. In addition, orientation-specific pulse distortion introduced by the antenna element is analyzed by means of the System Fidelity Factor (SFF). The SFF of the communication link between two instances of this antenna is higher than 94% for all directions within the antenna's -3 dB beamwidth. This easily wearable and deployable antenna is suitable to support IR-UWB localization with an accuracy in the order of 5 cm

    Comprehensive design and propagation study of a compact dual band antenna for healthcare applications

    Get PDF
    In this paper, a dual band planar inverted F antenna (PIFA) has been investigated for cooperative on- and off-body communications. Free space and on-body performance parameters like return loss, bandwidth, radiation pattern and efficiency of this antenna are shown and investigated. The on- and off-body radio propagation channel performance at 2.45 GHz and 1.9 GHz have been investigated, respectively. Experimental investigations are performed both in the anechoic chamber and in an indoor environment. The path loss exponent has been extracted for both on- and off-body radio propagation scenarios. For on-body propagation, the path loss exponent is 2.48 and 2.22 in the anechoic chamber and indoor environment, respectively. The path loss exponent is 1.27 for off-body radio propagation situation. For on-body case, the path loss has been characterized for ten different locations on the body at 2.45 GHz, whereas for off-body case radio channel studies are performed for five different locations at 1.9 GHz. The proposed antenna shows a good on- and off-body radio channel performance

    Design of a Finger Ring Antenna for Wireless Sensor Networks

    Get PDF
    Body-centric communications have become very active area of research due to ever-growing demand of portability. Advanced applications such as; health monitoring, tele-medicine, identification systems, performance monitoring of athletes, defence systems and personal entertainment are adding to its popularity. In this paper, a novel wearable antenna radiating at 5 GHz for the body-centric wireless sensor networks has been presented. The antenna consists of a conventional microstrip patch mounted on a gold base and could be worn in a finger like a ring. CST Microwave Studio is used for modelling, simulation and optimisation of the antenna. The simulated results show that the proposed antenna has a -10 dB bandwidth of 90.3 MHz with peak gain of 6.9 dBi. Good performance in terms of bandwidth, directivity, gain, return loss and radiation characteristics, along with a miniaturised form factor makes it a very well suited candidate for the body-worn wireless sensor applications

    Experimental Analysis of Ultra Wideband In Vivo Radio Channel

    Get PDF
    In this paper, we present the experimental analysis of in vivo wireless channel response on Ultra-Wideband (UWB) with the frequencies between 3.1-10.6 GHz. The analysis proves the location dependent based characteristics of in vivo channel. The results clearly show the highly multipath scenario. It can also be observed that the multipath effect of the channel is much higher in the denser areas, i.e. an antenna placed within the intestine area or inside the stomach. Results prove that in vivo channel is different from a conventional communication channel and therefore extensive studies need to be done to understand the channel

    Indoor wireless communications and applications

    Get PDF
    Chapter 3 addresses challenges in radio link and system design in indoor scenarios. Given the fact that most human activities take place in indoor environments, the need for supporting ubiquitous indoor data connectivity and location/tracking service becomes even more important than in the previous decades. Specific technical challenges addressed in this section are(i), modelling complex indoor radio channels for effective antenna deployment, (ii), potential of millimeter-wave (mm-wave) radios for supporting higher data rates, and (iii), feasible indoor localisation and tracking techniques, which are summarised in three dedicated sections of this chapter

    Body-Centric Radio Propagation Channels:characteristics and models

    Get PDF
    corecore