7 research outputs found

    Power Consumption Considerations for Ultrasound Capsule Endoscopy

    Get PDF
    Ultrasound capsule endoscopy (USCE) promises to combine the usefulness of the traditional endoscope with the increased comfort, reduced risks, and wider reach of a capsule for diagnosis of gastrointestinal tract (GIT) diseases. Equipped with a microultrasound (µUS) array operating at frequencies higher than 20 MHz, the USCE device can benefit from increased axial resolution, while the use of an array can provide a wider field of view via electronic beam-steering. However, reduced available power and limited physical dimensions are obstacles presently hindering the development of such medical devices. This paper proposes and evaluates US array driving techniques to reduce power consumption, discusses the limitations of receiving electronics and considers achievable B-mode imaging frame rates. Two array drivers were used in this study: a custom-made CMOS pulser, with details published previously, and a commercial research array controller (Vantage HF 128, Verasonics, WA, USA). Peak (i peak ) and average (i avg ) supply current measurements performed for a variable number of elements transmitting (Tx) simultaneously in a 28 MHz µUS array (Vermon, France) show that Tx apertures comprising <7 active elements are most suitable. Furthermore, because of the high i peak supplied to the array, charge storage on board the USCE device is required for any Tx configuration

    In-Vivo Evaluation of Microultrasound and Thermometric Capsule Endoscopes

    Get PDF
    Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a non-invasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (μUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of μUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of μUS B-scans and safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and μUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature μUS systems

    Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Get PDF

    Design and Simulation of a Ring-Shaped Linear Array for Microultrasound Capsule Endoscopy

    Get PDF
    Video capsule endoscopy (VCE) has significantly advanced visualization of the gastrointestinal tract (GI tract) since its introduction in the last 20 years. Work is now under way to combine VCE with microultrasound imaging. However, small maximum capsule dimensions, coupled with the electronics required to integrate ultrasound imaging capabilities, pose significant design challenges. This paper describes a simulation process for testing transducer geometries and imaging methodologies to achieve satisfactory imaging performance within the physical limitations of the capsule size and outlines many of the trade-offs needed in the design of this new class of ultrasound capsule endoscopy (USCE) device. A hybrid MATLAB model is described, incorporating KLM circuit elements and digitizing and beamforming elements to render a grey-scale B-mode. This model is combined with a model of acoustic propagation to generate images of point scatterers. The models are used to demonstrate the performance of a USCE transducer configuration comprising a single, unfocused transmit ring of radius 5 mm separated into eight segments for electrical impedance control and a 512-element receive linear array, also formed into a ring. The MATLAB model includes an ultrasonic pulser circuit connected to a piezocrystal composite transmit transducer with a center frequency of 25 MHz. B-scan images are simulated for wire target phantoms, multilayered phantoms, and a gut wall model. To demonstrate the USCE system’s ability to image tissue, a digital phantom was created from single-element ultrasonic transducer scans of porcine small bowel ex vivo obtained at a frequency of 45 MHz

    Development of a mechanical scanning device with high-frequency ultrasound transducer for ultrasonic capsule endoscopy

    No full text
    Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinaltract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementary solution as it is capable of acquiring transmural information from the tissue wall. This paper presents a mechanical scanning device incorporating a high-frequency transducer specifically as a proof of concept for US capsule endoscopy (USCE), providing information that may usefully assist future research. A rotary solenoid-coil-based motor was employed to rotate the US transducer with sectional electronic control. A set of gears was used to convert the sectional rotation to circular rotation. A single-element focused US transducer with 39-MHz center frequency was used for high-resolution US imaging, connected to an imaging platform for pulse generation and image processing. Key parameters of US imaging for USCE applications were evaluated. Wire phantom imaging and tissue phantom imaging have been conducted to evaluate the performance of the proposed method. A porcine small intestine specimen was also used for imaging evaluation in vitro. Test results demonstrate that the proposed device and rotation mechanism are able to offer good image resolution ( ~60 μm) of the lumen wall, and they, therefore, offer a viable basis for the fabrication of a USCE device

    Development of electronics for microultrasound capsule endoscopy

    Get PDF
    Development of intracorporeal devices has surged in the last decade due to advancements in the semiconductor industry, energy storage and low-power sensing systems. This work aims to present a thorough systematic overview and exploration of the microultrasound (µUS) capsule endoscopy (CE) field as the development of electronic components will be key to a successful applicable µUSCE device. The research focused on investigating and designing high-voltage (HV, < 36 V) generating and driving circuits as well as a low-noise amplifier (LNA) for battery-powered and volume-limited systems. In implantable applications, HV generation with maximum efficiency is required to improve the operational lifetime whilst reducing the cost of the device. A fully integrated hybrid (H) charge pump (CP) comprising a serial-parallel (SP) stage was designed and manufactured for > 20 V and 0 - 100 µA output capabilities. The results were compared to a Dickson (DKCP) occupying the same chip area; further improvements in the SPCP topology were explored and a new switching scheme for SPCPs was introduced. A second regulated CP version was excogitated and manufactured to use with an integrated µUS pulse generator. The CP was manufactured and tested at different output currents and capacitive loads; its operation with an US pulser was evaluated and a novel self-oscillating CP mechanism to eliminate the need of an auxiliary clock generator with a minimum area overhead was devised. A single-output universal US pulser was designed, manufactured and tested with 1.5 MHz, 3 MHz, and 28 MHz arrays to achieve a means of fully-integrated, low-power transducer driving. The circuit was evaluated for power consumption and pulse generation capabilities with different loads. Pulse-echo measurements were carried out and compared with those from a commercial US research system to characterise and understand the quality of the generated pulse. A second pulser version for a 28 MHz array was derived to allow control of individual elements. The work involved its optimisation methodology and design of a novel HV feedback-based level-shifter. A low-noise amplifier (LNA) was designed for a wide bandwidth µUS array with a centre frequency of 28 MHz. The LNA was based on an energy-efficient inverter architecture. The circuit encompassed a full power-down functionality and was investigated for a self-biased operation to achieve lower chip area. The explored concepts enable realisation of low power and high performance LNAs for µUS frequencies