2 research outputs found

    A New Proposal for OFCC-based Instrumentation Amplifier

    Get PDF
    This contribution puts forward a new voltage mode instrumentation amplifier (VMIA) based on operational floating current conveyor (OFCC). It presents high impedance at input terminals and provides output at low impedance making the proposal ideal for voltage mode operation. The proposed VMIA architecture has two stages - the first stage comprises of two OFCCs to sense input voltages and coverts the voltage difference to current while the second stage has single OFCC that converts the current to voltage. In addition it employs two resistors to provide gain and imposes no condition on the values of resistors.  The behavior of the proposed structure is also analyzed for OFCC non idealities namely finite transimpedance and tracking error. The proposal is verified through SPICE simulations using CMOS based schematic of OFCC. Experimental results, by bread boarding it using commercially available IC AD844, are also included

    Bladder Volume Decoding from Afferent Neural Activity

    Get PDF
    RÉSUMÉ Lorsque les fonctions de stockage et de miction de la vessie échouent à la suite de traumatismes médullaires, ou en raison d'autres maladies neurologiques, de conditions de santé ou au vieillissement, des complications graves pour la santé du patient se produisent. Actuellement, il est possible de restaurer partiellement les fonctions de la vessie chez les patients réfractaires aux médicaments à l'aide des neurostimulateurs implantables. Pour améliorer l'efficacité et la sécurité de ces neuroprothèses, il faut un capteur de la vessie capable de détecter l’urine stockée afin de mettre en place un système en boucle fermée qui applique la stimulation électrique uniquement lorsque nécessaire. Le capteur peut également servir à aviser les patients ayant des sensations affaiblies pour les aviser en temps opportun le moment où la vessie doit être vidée ou quand un volume résiduel postmictionnel anormalement élevé reste après une miction incomplète. Dans cette thèse, on présente de nouvelles méthodes de mesure, ainsi qu’un processeur de signal numérique dédié pour décoder en temps réel le volume de la vessie à partir des enregistrements neuronaux afférents provenant des récepteurs naturels présents dans la paroi de la vessie. Nos principales contributions sont rapportées dans trois articles de journaux avec comité de lecture. On présente d'abord une revue exhaustive de la littérature comprenant des articles de journaux, des brevets et les livres les plus réputés portant sur l'anatomie, la physiologie et la physiopathologie du tractus urinaire inférieur ainsi que sur la mesure du volume ou la pression de la vessie. Cette étude nous a permis d'identifier les besoins qu'un capteur de la vessie doit satisfaire pour être utilisé dans des applications chroniques telles que celles proposées dans cette thèse. On présente aussi le résultat d’une analyse exhaustive des caractéristiques anatomiques et physiologiques de la vessie que nous avons identifiées d’avoir exercé une influence, ou même d’avoir empêché, la réalisation d'un tel capteur dans des études faites au cours des dernières années. Sur la base de cette étude et de l'évaluation systématique des méthodes de mesure pour la vessie, on a conclu que le principe de mesure le mieux adapté pour la surveillance chronique du volume de la vessie était la détection, la discrimination et le décodage de l'activité neuronale afférente découlant des récepteurs spécialisés du volume (mécanorécepteurs), au sujet desquels certains auteurs ont émis l'hypothèse de leur existence dans la muqueuse interne de la vessie. Ensuite, on présente la méthode de mesure qui permet d'estimer en temps réel le volume de la vessie à partir de l'activité afférente des mécanorécepteurs. Notre méthode a été validée avec les----------ABSTRACT Failure of the storage and voiding functions of the urinary bladder due to spinal cord injury (SCI), neural diseases, health conditions, or aging, causes serious complications in a patient's health. Currently, it is possible to partially restore bladder functions in drug-refractory patients using implantable neurostimulators. Improving the efficacy and safety of these neuroprostheses used for bladder functions restoration requires a bladder sensor (BS) capable of detecting urine volume in real-time to implement a closed-loop system that applies electrical stimulation only when required. The BS can also trigger an early warning to advise patients with impaired sensations when the bladder should be voided or when an abnormally high post-voiding residual volume remains after an incomplete voiding. In this thesis, we present new measurement methods and a dedicated digital signal processor for real-time decoding of the bladder volume through afferent neural signals arising from natural receptors present in the bladder wall. The main contributions of this thesis have been reported in three peer-reviewed journal papers. We first present a comprehensive literature review, including papers, patents and mainstay books of bladder anatomy, physiology, and pathophysiology. This review allowed us to identify the requirements (user needs) that a BS must meet for chronic applications, such as those proposed in this thesis. An exhaustive analysis of the particular anatomical and physiological characteristics of the bladder, which we realized had influenced or prevented the achievement of a BS for monitoring the bladder volume or pressure in past studies, are also presented. Based on this study and on a systematic assessment of the measurement methods published in past years, we determined the best measurement principle for chronic bladder volume monitoring: the detection, discrimination and decoding of the afferent neural activity stemming from specialized volume receptors (mechanoreceptors), on which some authors had hypothesized about its existence in the bladder inner mucosa. Next, we present methods that allows for a real-time estimation of bladder volume through the afferent activity of the bladder mechanoreceptors. Our method was validated with data acquired from anesthetized rats in acute experiments. It was possible to qualitatively estimate three states of bladder fullness in 100% of trials when the recorded afferent activity exhibited a Spearman’s correlation coefficient of 0.6 or better. Furthermore, we could quantitatively estimate the bladder volume, and also its pressure, using time-windows of properly chosen duration. The mea
    corecore