23 research outputs found

    Practical control methods for vacuum driven soft actuator modules

    Get PDF
    Vacuum-powered Soft Pneumatic Actuator (VSPA) Modules have been described to afford advantages for rapid development of reconfigurable, multi-DoF soft pneumatic robots powered by vacuum by reducing their logistical complexity, however they also present new challenges in the control of resulting systems. This framework features modules joined together over a simple embedded pneumatic and serial communication network and requires a unique approach to both low-level control implementation and high-level control strategy. We describe the structure and activation characteristics of a V-SPA Module and present practical methods for its control. These methods utilize software generated PWM activation through a unique serial protocol designed for LED networks and a heuristic mapping strategy for simplifying the spherical control of 3-DoF actuator modules

    Towards an ontology for soft robots: What is soft?

    Get PDF
    The advent of soft robotics represents a profound change in the forms robots will take in the future. However, this revolutionary change has already yielded such a diverse collection of robots that attempts at defining this group do not reflect many existing ‘soft’ robots. This paper aims to address this issue by scrutinising a number of descriptions of soft robots arising from a literature review with the intention of determining a coherent meaning for soft. We also present a classification of existing soft robots to initiate the development of a soft robotic ontology. Finally, discrepancies in prescribed ranges of Young’s modulus, a frequently used criterion for the selection of soft materials, are explained and discussed. A detailed visual comparison of these ranges and supporting data is also presented

    Design, fabrication and control of soft robots

    Get PDF
    Conventionally, engineers have employed rigid materials to fabricate precise, predictable robotic systems, which are easily modelled as rigid members connected at discrete joints. Natural systems, however, often match or exceed the performance of robotic systems with deformable bodies. Cephalopods, for example, achieve amazing feats of manipulation and locomotion without a skeleton; even vertebrates such as humans achieve dynamic gaits by storing elastic energy in their compliant bones and soft tissues. Inspired by nature, engineers have begun to explore the design and control of soft-bodied robots composed of compliant materials. This Review discusses recent developments in the emerging field of soft robotics.National Science Foundation (U.S.) (Grant IIS-1226883

    Macrobend optical sensing for pose measurement in soft robot arms

    Get PDF
    This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic tracking system (NDI Aurora) for validation

    Real-time simulation of hydraulic components for interactive control of soft robots

    Get PDF
    International audienceIn this work we propose a new method for online motion planning in the task-space for hydraulic actuated soft robots. Our solution relies on the interactive resolution of an inverse kinematics problem, that takes into account the properties (mass, stiffness) of the deformable material used to build the robot. An accurate modeling of the mechanical behavior of hydraulic components is based on a novel GPU parallel method for the real-time computation of fluid weight distribution. The efficiency of the method is further increased by a novel GPU parallel leveraging mechanism. Our complete solution has been integrated within the open-source SOFA framework. In our results, we validate our simulation with a fabricated silicone cylinder and we demonstrate the usage of our approach for direct control of hydraulic soft robots

    Visual Servoing Control of Soft Robots based on Finite Element Model

    Get PDF
    International audienceIn this paper, we propose a strategy for the control of soft robots with visual tracking and simulation-based predictor. A kinematic model of soft robots is obtained thanks to the Finite Element Method (FEM) computed in real-time. The FEM allows to obtain a prediction of the Jacobian matrix of the robot. This allows a first control of the robot, in the actuator space. Then, a second control strategy based on the feedback of infrared cameras is developed to obtain a correction of the effector position. The robust stability of this closed-loop system is obtained based on Lyapunov stability theory. Otherwise, to deal with the problem of image features (the marker points placed on the end effector of soft robot) loss, a switched control strategy is proposed to combine both the open-loop controller and the closed-loop controller. Finally, experiments on a parallel soft robot driven by four cables are conducted and show the effectiveness of these methods for the real-time control of soft robots

    Design and integration of a parallel, soft robotic end-effector for extracorporeal ultrasound

    Get PDF
    Objective: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. Methods: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. Results: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of 1.18+/-0.29mm in position and 0.92+/-0.47deg in orientation. The derived controller is, with an average position error of 0.39mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. Conclusion: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. Significance: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks
    corecore