3,861 research outputs found
State-of-the-art in Power Line Communications: from the Applications to the Medium
In recent decades, power line communication has attracted considerable
attention from the research community and industry, as well as from regulatory
and standardization bodies. In this article we provide an overview of both
narrowband and broadband systems, covering potential applications, regulatory
and standardization efforts and recent research advancements in channel
characterization, physical layer performance, medium access and higher layer
specifications and evaluations. We also identify areas of current and further
study that will enable the continued success of power line communication
technology.Comment: 19 pages, 12 figures. Accepted for publication, IEEE Journal on
Selected Areas in Communications. Special Issue on Power Line Communications
and its Integration with the Networking Ecosystem. 201
PLC for the smart grid: state-of-the-art and challenges
This paper aims to review systems and applications for power line communications (PLC) in the context of the smart grid. We discuss the main applications and summarise state-of-the-art PLC systems and standards. We report efforts and challenges in channel and noise modelling, as well as in state-of-the-art transmission technology approaches
Experimental study of 6LoPLC for home energy management systems
© 2016 by the authors. Ubiquitous connectivity is already transforming residential dwellings into smart homes. As citizens continue to embrace the smart home paradigm, a new generation of low-rate and low-power communication systems is required to leverage the mass market presented by energy management in homes. Although Power Line Communication (PLC) technology has evolved in the last decade, the adaptation of PLC for constrained networks is not fully charted. By adapting some features of IEEE 802.15.4 and IPv6 over Low-power Wireless Personal Area Network (6LoWPAN) into power lines, this paper demonstrates a low-rate, low-power PLC system over the IPv6 network (referred to as 6LoPLC), for Home Energy Management System (HEMS) applications. The overall idea is to provide a framework for assessing various scenarios that cannot be easily investigated with the limited number of evaluation hardware available. In this respect, a network model is developed in NS-3 (Version 21) to measure several important characteristics of the designed system and then validated with experimental results obtained using the Hanadu evaluation kits. Following the good agreement between the two, the NS-3 model is utilised to investigate more complex scenarios and various use-cases, such as the effects of impulsive noise, the number of nodes and packet size on the latency and Bit Error Rate (BER) performances. We further demonstrate that for different network and application configurations, optimal data sizes exist. For instance, the results reveal that in order to guarantee 99% system reliability, the HEMS application data must not exceed 64 bytes. Finally, it is shown that with impulsive noise in a HEMS network comprising 50 appliances, provided the size of the payload does not exceed 64 bytes, monitoring and control applications incur a maximum latency of 238.117 ms and 248.959 ms, respectively; both of which are within acceptable limits
Energy-Efficient Vector OFDM PLC Systems with Dynamic Peak-Based Threshold Estimation
© 2013 IEEE. Power line communication (PLC) has made remarkable strides to become a key enabler of smart grid and its applications. Existing PLC systems are based on orthogonal frequency division multiplexing (OFDM), which has a high peak-to-average power ratio (PAPR). This paper presents vector OFDM (VOFDM) with advanced signal processing at the receiver to improve the energy efficiency of the PLC system. Results show that, due to its low PAPR properties, VOFDM is less sensitive to impulsive noise and provides a reduction of 5.8 dB in transmit power requirement relative to conventional OFDM. Furthermore, unlike the existing impulsive noise cancellation methods, the adopted signal processing technique also improves the SNR at the receiver by 2.1 dB, which further reduces the power requirement of the PLC transceiver. Together, these can simplify design, reduce cost, and improve energy efficiency of future PLC transceivers
Fifty Years of Noise Modeling and Mitigation in Power-Line Communications.
Building on the ubiquity of electric power infrastructure, power line communications (PLC) has been successfully used in diverse application scenarios, including the smart grid and in-home broadband communications systems as well as industrial and home automation. However, the power line channel exhibits deleterious properties, one of which is its hostile noise environment. This article aims for providing a review of noise modeling and mitigation techniques in PLC. Specifically, a comprehensive review of representative noise models developed over the past fifty years is presented, including both the empirical models based on measurement campaigns and simplified mathematical models. Following this, we provide an extensive survey of the suite of noise mitigation schemes, categorizing them into mitigation at the transmitter as well as parametric and non-parametric techniques employed at the receiver. Furthermore, since the accuracy of channel estimation in PLC is affected by noise, we review the literature of joint noise mitigation and channel estimation solutions. Finally, a number of directions are outlined for future research on both noise modeling and mitigation in PLC
Unequal error protection for power line communications over impulsive noise channels
Power line communication (PLC) has recently attracted a lot of interest with many application areas including smart grids\u27 data communication, where data (from sensors or other measurement units) with different QoS may be transmitted. Power line communications suffer from the excessive power lines\u27 impulsive noise (which can be caused by shedding loads on and off). In this thesis, we present a study of power line communications with unequal error protection for two and four data priority levels hierarchical QAM modulation and space-time block coding. We consider the two commonly used power lines\u27 impulsive noise models with Bernoulli and Poisson arrivals. In our proposed approaches, we achieve UEP on both of bit and symbol levels. Approximate closed form expressions for the error rates are derived for each priority level for both single carrier and OFDM in SISO and MIMO systems. In addition, these simpli fied expressions are used to implement a bit loading algorithm to provide UEP for frequency-selective PLC channels. For the case of MIMO PLC channels, we describe three different MIMO schemes to allow more control over the UEP levels. The three schemes are namely: maximum ratio combiner (MRC) receive diversity, Alamouti space-time block code, and a new structure for a space-time code that allows for unequal error protection at the symbol level. Finally, we apply an Eigen beamforming technique, assuming channel knowledge at transmitter, which improves the BER as compared to the other MIMO PLC schemes
Characterization of non-intentional emissions from distributed energy resources up to 500âŻkHz: A case study in Spain
Narrow Band Power Line Communications (NB-PLC) systems are currently used for smart metering and power quality monitoring as a part of the Smart Grid (SG) concept. However, non-intentional emissions generated by the devices connected to the grid may sometimes disturb the communications and isolate metering equipment. Though some research works have been recently developed to characterize these emissions, most of them have been limited to frequencies below 150âŻkHz and they are mainly focused on in-house electronic appliances and lightning devices. As NB-PLC can also be allocated in higher frequencies up to 500âŻkHz, there is still a lack of analysis in this frequency range, especially for emissions from Distributed Energy Resources (DERs). The identification and characterization of the emissions is essential to develop solutions that avoid a negative impact on the proper performance of NB-PLC.
In this work, the non-intentional emissions of different types of DERs composing a representative microgrid have been measured in the 35â500âŻkHz frequency range and analyzed both in time and frequency domains. Different working conditions and coupling and commutation procedures to mains are considered in the analysis. Results are then compared to the limits recommended by regulatory bodies for spurious emissions from communication systems in this frequency band, as no specific limits for DERs have been established. Field measurements show clear differences in the characteristics of non-intentional emissions for different devices, working conditions and coupling procedures and for frequencies below and above 150âŻkHz. Results of this study demonstrate that a further characterization of the potential emissions from the different types of DERs connected to the grid is required in order to guarantee current and future applications based on NB-PLC.This work has been financially supported in part by the Basque
Government (Elkartek program)