12,262 research outputs found

    Systems and methods for correcting optical reflectance measurements

    Get PDF
    We disclose measurement systems and methods for measuring analytes in target regions of samples that also include features overlying the target regions. The systems include: (a) a light source; (b) a detection system; (c) a set of at least first, second, and third light ports which transmit light from the light source to a sample and receive and direct light reflected from the sample to the detection system, generating a first set of data including information corresponding to both an internal target within the sample and features overlying the internal target, and a second set of data including information corresponding to features overlying the internal target; and (d) a processor configured to remove information characteristic of the overlying features from the first set of data using the first and second sets of data to produce corrected information representing the internal target

    Systems and Methods for Correcting Optical Reflectance Measurements

    Get PDF
    We disclose measurement systems and methods for measuring analytes in target regions of samples that also include features overlying the target regions. The systems include: (a) a light source; (b) a detection system; (c) a set of at least first, second, and third light ports which transmit light from the light source to a sample and receive and direct light reflected from the sample to the detection system, generating a first set of data including information corresponding to both an internal target within the sample and features overlying the internal target, and a second set of data including information corresponding to features overlying the internal target; and (d) a processor configured to remove information characteristic of the overlying features from the first set of data using the first and second sets of data to produce corrected information representing the internal target

    Acquisition strategies for fat/water separated MRI

    Get PDF
    This thesis focuses on new ways to more efficiently acquire the signal for fat/water separated MRI, also known as Dixon methods. In paper I, the concept of dual bandwidths was introduced to improve SNR efficiency by removing dead times in a spin echo PROPELLER sequence. By correcting for the displacement of fat, we were able to improve the motion correction. This required additional considerations during reconstruction in order to avoid noise amplification, which was solved with a noise-whitening Tikhonov regularization. Paper II explores the combination of fat/water separation in k-space with partially acquired data, i.e. partial Fourier sampling. With reduced sampling coverage comes the ability of increased spatial resolution, which is often limited in fat/water imaging, particularly in gradient echo sequences. A modified POCS routine was also developed with real-valued estimates, exploiting Hermitian symmetry to improve the inverse problem conditioning in the fully sampled region. A single-TR dual-bandwidth RARE (fast/turbo spin echo) sequence without dead times was developed in Paper III, which uses partial Fourier sampling with late and early echoes to improve the chemical shift encoding. The proposed sequence can acquire images with 0.5 mm in-plane resolution without dead times, with image quality exceeding current state-of-the-art techniques. An automated selection of gradient waveforms based on Cramér-Rao bounds was implemented on the scanner. In Paper IV, the dual-bandwidth concept was generalized to continuous bandwidths. Instead of the conventional shift of a trapezoidal readout gradient, we describe a new method of encoding chemical shift by using asymmetric readout waveforms. Asymmetric readouts were implemented in a RARE sequence to completely remove dead times from multi-TR acquisitions, with typical scan time reductions of 25 %. The developed methods enable fat/water imaging with reduced scan times and increased spatial resolution, which has previously limited their use

    The Effects of Relative Food Prices on Obesity – Evidence from China: 1991-2006

    Get PDF
    This paper explores the effects of relative food prices on body weight and body fat over time in China. We study a cohort of 15,000 adults from over 200 communities in China, using the longitudinal China Health and Nutrition Survey (1991-2006). While we find that decreases in the price of energy-dense foods have consistently led to elevated body fat, this price effect does not always hold for body weight. These findings suggest that changes in food consumption patterns induced by varying food prices can increase percentage body fat to risky levels even without substantial weight gain. In addition, food prices and subsidies could be used to encourage healthier food consumption patterns and to curb obesity.Agricultural and Food Policy, Consumer/Household Economics, Demand and Price Analysis, Food Consumption/Nutrition/Food Safety, Health Economics and Policy,

    Measuring tissue oxygenation

    Get PDF
    Methods and systems for calculating tissue oxygenation, e.g., oxygen saturation, in a target tissue are disclosed. In some embodiments, the methods include: (a) directing incident radiation to a target tissue and determining reflectance spectra of the target tissue by measuring intensities of reflected radiation from the target tissue at a plurality of radiation wavelengths; (b) correcting the measured intensities of the reflectance spectra to reduce contributions thereto from skin and fat layers through which the incident radiation propagates; (c) determining oxygen saturation in the target tissue based on the corrected reflectance spectra; and (d) outputting the determined value of oxygen saturation

    Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions

    Get PDF
    Purpose: To address phase and amplitude errors for multi-point water-fat separation with bipolar acquisitions, which efficiently collect all echoes with alternating read-out gradient polarities in one repetition. Materials and Methods: With the bipolar acquisitions, eddy currents and other system nonidealities can induce inconsistent phase errors between echoes, disrupting water-fat separation. Previous studies have addressed phase correction in the read-out direction. However, the bipolar acquisitions may be subject to spatially high order phase errors as well as an amplitude modulation in the read-out direction. A method to correct for the 2D phase and amplitude errors is introduced. Low resolution reference data with reversed gradient polarities are collected. From the pair of low-resolution data collected with opposite gradient polarities, the two-dimensional phase errors are estimated and corrected. The pair of data are then combined for water-fat separation. Results: We demonstrate that the proposed method can effectively remove the high order errors with phantom and in vivo experiments, including obliquely oriented scans. Conclusion: For bipolar multi-echo acquisitions, uniform water-fat separation can be achieved by removing high order phase errors with the proposed method. © 2010 Wiley-Liss, Inc

    The impact of susceptibility correction on diffusion metrics in adolescents

    Get PDF
    Background Diffusion tensor imaging is a widely used imaging method of brain white matter, but it is prone to imaging artifacts. The data corrections can affect the measured values. Objective To explore the impact of susceptibility correction on diffusion metrics. Materials and methods A cohort of 27 healthy adolescents (18 boys, 9 girls, mean age 12.7 years) underwent 3-T MRI, and we collected two diffusion data sets (anterior-posterior). The data were processed both with and without susceptibility artifact correction. We derived fractional anisotropy, mean diffusivity and histogram data of fiber length distribution from both the corrected and uncorrected data, which were collected from the corpus callosum, corticospinal tract and cingulum bilaterally. Results Fractional anisotropy and mean diffusivity values significantly differed when comparing the pathways in all measured tracts. The fractional anisotropy values were lower and the mean diffusivity values higher in the susceptibility-corrected data than in the uncorrected data. We found a significant difference in total tract length in the corpus callosum and the corticospinal tract. Conclusion This study indicates that susceptibility correction has a significant effect on measured fractional anisotropy, and on mean diffusivity values and tract lengths. To receive reliable and comparable results, the correction should be used systematically.Peer reviewe

    Automated Assessment of T2-Weighted MRI to Differentiate Malignant and Benign Primary Solid Liver Lesions in Noncirrhotic Livers Using Radiomics

    Get PDF
    Rationale and Objectives: Distinguishing malignant from benign liver lesions based on magnetic resonance imaging (MRI) is an important but often challenging task, especially in noncirrhotic livers. We developed and externally validated a radiomics model to quantitatively assess T2-weighted MRI to distinguish the most common malignant and benign primary solid liver lesions in noncirrhotic livers. Materials and Methods: Data sets were retrospectively collected from three tertiary referral centers (A, B, and C) between 2002 and 2018. Patients with malignant (hepatocellular carcinoma and intrahepatic cholangiocarcinoma) and benign (hepatocellular adenoma and focal nodular hyperplasia) lesions were included. A radiomics model based on T2-weighted MRI was developed in data set A using a combination of machine learning approaches. The model was internally evaluated on data set A through cross-validation, externally validated on data sets B and C, and compared to visual scoring of two experienced abdominal radiologists on data set C. Results: The overall data set included 486 patients (A: 187, B: 98, and C: 201). The radiomics model had a mean area under the curve (AUC) of 0.78 upon internal validation on data set A and a similar AUC in external validation (B: 0.74 and C: 0.76). In data set C, the two radiologists showed moderate agreement (Cohen's Îş: 0.61) and achieved AUCs of 0.86 and 0.82. Conclusion: Our T2-weighted MRI radiomics model shows potential for distinguishing malignant from benign primary solid liver lesions. External validation indicated that the model is generalizable despite substantial MRI acquisition protocol differences. Pending further optimization and generalization, this model may aid radiologists in improving the diagnostic workup of patients with liver lesions.</p
    • …
    corecore