31,021 research outputs found

    Numerical and experimental assessment of the modal curvature method for damage detection in plate structures

    Get PDF
    Use of modal curvatures obtained from modal displacement data for damage detection in isotropic and composite laminated plates is addressed through numerical examples and experimental tests. Numerical simulations are carried out employing COMSOL Multiphysics as finite element solver of the equations governing the Mindlin-Reissner plate model. Damages are introduced as localized non-smooth variations of the bending stiffness of the baseline (healthy) configuration. Experiments are also performed on steel and aluminum plates using scanning laser vibrometry. The obtained results confirm that use of the central difference method to compute modal curvatures greatly amplifies the measurement errors and its application leads to unreliable predictions for damage detection, even after denoising. Therefore, specialized ad hoc numerical techniques must be suitably implemented to enable structural health monitoring via modal curvature changes. In this study, the Savitzky-Golay filter (also referred to as least-square smoothing filter) is considered for the numerical differentiation of noisy data. Numerical and experimental results show that this filter is effective for the reliable computation of modal curvature changes in plate structures due to defects and/or damages

    Damage monitoring in sandwich beams by modal parameter shifts: a comparative study of burst random and sine dwell vibration testing

    Get PDF
    This paper presents an experimental study on the effects of multi-site damage on the vibration response of honeycomb sandwich beams, damaged by two different ways i.e., impact damage and core-only damage simulating damage due to bird or stone impact or due to mishandling during assembly and maintenance. The variation of the modal parameters with different levels of impact energy and density of damage is studied. Vibration tests have been carried out with both burst random and sine dwell testing in order to evaluate the damping estimation efficiency of these methods in the presence of damage. Sine dwell testing is done in both up and down frequency directions in order to detect structural non-linearities. Results show that damping ratio is a more sensitive parameter for damage detection than the natural frequency. Design of experiments (DOE) highlighted density of damage as the factor having a more significant effect on the modal parameters and also proved that sine dwell testing is more suitable for damping estimation in the presence of damage as compared to burst random testing

    Resonant Characteristics of Rectangular Hammerhead Microcantilevers Vibrating Laterally in Viscous Liquid Media

    Get PDF
    The resonant characteristics of laterally vibrating rectangular hammerhead microcantilevers in viscous liquid media are investigated. The rectangular hammerhead microcantilever is modeled as an Euler-Bernoulli beam (stem) and a rigid body (head). A modified semi-analytical expression for the hydrodynamic function in terms of the Reynolds number, Re, and aspect ratio, h/b, is proposed to rapidly evaluate the sensing characteristics. Using this expression, the resonance frequency, quality factor and normalized surface mass sensitivity are investigated as a function of the dimensions of the microcantilever and liquid properties. Guidelines for design of hammerhead microcantilever geometry are proposed to achieve efficient sensing platforms for liquid-phase operation. The improvement in the sensing area and characteristics are expected to yield higher sensitivity of detection and improved signal-to-noise ratio in liquid-phase chemical sensing applications

    Computer-aided position planning of miniplates to treat facial bone defects

    Full text link
    In this contribution, a software system for computer-aided position planning of miniplates to treat facial bone defects is proposed. The intra-operatively used bone plates have to be passively adapted on the underlying bone contours for adequate bone fragment stabilization. However, this procedure can lead to frequent intra-operatively performed material readjustments especially in complex surgical cases. Our approach is able to fit a selection of common implant models on the surgeon's desired position in a 3D computer model. This happens with respect to the surrounding anatomical structures, always including the possibility of adjusting both the direction and the position of the used osteosynthesis material. By using the proposed software, surgeons are able to pre-plan the out coming implant in its form and morphology with the aid of a computer-visualized model within a few minutes. Further, the resulting model can be stored in STL file format, the commonly used format for 3D printing. Using this technology, surgeons are able to print the virtual generated implant, or create an individually designed bending tool. This method leads to adapted osteosynthesis materials according to the surrounding anatomy and requires further a minimum amount of money and time.Comment: 19 pages, 13 Figures, 2 Table

    Geometrical Considerations for the Design of Liquid-phase Biochemical Sensors Using a Cantilever\u27s Fundamental In-plane Mode

    Get PDF
    The influence of the beam geometry on the quality factor and resonance frequency of resonant silicon cantilever beams vibrating in their fundamental in-plane flexural mode in water has been investigated. Compared to cantilevers vibrating in their first out-of-plane flexural mode, utilizing the in-plane mode results in reduced damping and reduced mass loading by the surrounding fluid. Quality factors as high as 86 have been measured in water for cantilevers with a 20 μm thick silicon layer. Based on the experimental data, design guidelines are established for beam dimensions that ensure maximal Q-factors and minimal mass loading by the surrounding fluid, thus improving the limit-of-detection of mass-sensitive biochemical sensors. Elementary theory is also presented to help explain the observed trends. Additional discussion focuses on the tradeoffs that exist in designing liquid-phase biochemical sensors using in-plane cantilevers

    Holographic and ultrasonic detection of bond flaws in aluminum panels reinforced with boron-epoxy

    Get PDF
    An experimental investigation was made of the application of holographic interferometry to the nondestructive detection of unbonded areas (flaws) in bonded panels. Flaw detection results were compared with results obtained with an ultrasonic flaw detector. Holography, with panel deformation accomplished by a reduction in ambient pressure, is less sensitive for flaws beneath 5 and 10 plies of boron-epoxy than the ultrasonic method, though it does have its operational advantages. A process for the manufacture of bonded panels which incorporate known unbonded areas was also developed. The unbonded areas were formed without the use of foreign materials, which makes the method suitable for the construction of reference standards for bonded panels whenever needed for the proper setup of ultrasonic flaw-detection instruments
    • …
    corecore