262 research outputs found

    The automatic detection of lumber anatomy in epidural injections for ultrasound guidance

    Full text link
    The purpose of this paper is to help the anesthesiologist to find the epidural depth automatically to make the first attempt to enter the path of the needle into the patient's body while it is clogged with bone and avoid causing a puncture in the surrounding areas of the patient`s back. In this regard, a morphology-based bone enhancement and detection followed by a Ramer-Douglas-Peucker algorithm and Hough transform is proposed. The proposed algorithm is tested on synthetic and real ultrasound images of laminar bone, and the results are compared with the template matching based Ligamentum Flavum (LF) detection method. Results indicate that the proposed method can faster detect the diagonal shape of the laminar bone and its corresponding epidural depth. Furthermore, the proposed method is reliable enough providing anesthesiologists with real-time information while an epidural needle insertion is performed. It has to be noted that using the ultrasound images is to help anesthesiologists to perform the blind injection, and due to quite a lot of errors occurred in ultrasound-imaging-based methods, these methods can not completely replace the tissue pressure-based method. And in the end, when the needle is injected into the area (dura space) measurements can only be trusted to the extent of tissue resistance. Despite the fairly limited amount of training data available in this study, a significant improvement of the segmentation speed of lumbar bones and epidural depth in ultrasound scans with a rational accuracy compared to the LF-based detection method was found.Comment: 34 pages, To be published in Medical Hypothese

    Advances in Bioengineering

    Get PDF
    The technological approach and the high level of innovation make bioengineering extremely dynamic and this forces researchers to continuous updating. It involves the publication of the results of the latest scientific research. This book covers a wide range of aspects and issues related to advances in bioengineering research with a particular focus on innovative technologies and applications. The book consists of 13 scientific contributions divided in four sections: Materials Science; Biosensors. Electronics and Telemetry; Light Therapy; Computing and Analysis Techniques

    Proceedings of ICMMB2014

    Get PDF

    Post formation processing of cardiac ultrasound data for enhancing image quality and diagnostic value

    Get PDF
    Cardiovascular diseases (CVDs) constitute a leading cause of death, including premature death, in the developed world. The early diagnosis and treatment of CVDs is therefore of great importance. Modern imaging modalities enable the quantification and analysis of the cardiovascular system and provide researchers and clinicians with valuable tools for the diagnosis and treatment of CVDs. In particular, echocardiography offers a number of advantages, compared to other imaging modalities, making it a prevalent tool for assessing cardiac morphology and function. However, cardiac ultrasound images can suffer from a range of artifacts reducing their image quality and diagnostic value. As a result, there is great interest in the development of processing techniques that address such limitations. This thesis introduces and quantitatively evaluates four methods that enhance clinical cardiac ultrasound data by utilising information which until now has been predominantly disregarded. All methods introduced in this thesis utilise multiple partially uncorrelated instances of a cardiac cycle in order to acquire the information required to suppress or enhance certain image features. No filtering out of information is performed at any stage throughout the processing. This constitutes the main differentiation to previous data enhancement approaches which tend to filter out information based on some static or adaptive selection criteria. The first two image enhancement methods utilise spatial averaging of partially uncorrelated data acquired through a single acoustic window. More precisely, Temporal Compounding enhances cardiac ultrasound data by averaging partially uncorrelated instances of the imaged structure acquired over a number of consecutive cardiac cycles. An extension to the notion of spatial compounding of cardiac ultrasound data is 3D-to-2D Compounding, which presents a novel image enhancement method by acquiring and compounding spatially adjacent (along the elevation plane), partially uncorrelated, 2D slices of the heart extracted as a thin angular sub-sector of a volumetric pyramid scan. Data enhancement introduced by both approaches includes the substantial suppression of tissue speckle and cavity noise. Furthermore, by averaging decorrelated instances of the same cardiac structure, both compounding methods can enhance tissue structures, which are masked out by high levels of noise and shadowing, increasing their corresponding tissue/cavity detectability. The third novel data enhancement approach, referred as Dynamic Histogram Based Intensity Mapping (DHBIM), investigates the temporal variations within image histograms of consecutive frames in order to (i) identify any unutilised/underutilised intensity levels and (ii) derive the tissue/cavity intensity threshold within the processed frame sequence. Piecewise intensity mapping is then used to enhance cardiac ultrasound data. DHBIM introduces cavity noise suppression, enhancement of tissue speckle information as well as considerable increase in tissue/cavity contrast and detectability. A data acquisition and analysis protocol for integrating the dynamic intensity mapping along with spatial compounding methods is also investigated. The linear integration of DHBIM and Temporal Compounding forms the fourth and final implemented method, which is also quantitatively assessed. By taking advantage of the benefits and compensating for the limitations of each individual method, the integrated method suppresses cavity noise and tissue speckle while enhancing tissue/cavity contrast as well as the delineation of cardiac tissue boundaries even when heavily corrupted by cardiac ultrasound artifacts. Finally, a novel protocol for the quantitative assessment of the effect of each data enhancement method on image quality and diagnostic value is employed. This enables the quantitative evaluation of each method as well as the comparison between individual methods using clinical data from 32 patients. Image quality is assessed using a range of quantitative measures such as signal-to-noise ratio, tissue/cavity contrast and detectability index. Diagnostic value is assessed through variations in the repeatability level of routine clinical measurements performed on patient cardiac ultrasound scans by two experienced echocardiographers. Commonly used clinical measures such as the wall thickness of the Interventricular Septum (IVS) and the Left Ventricle Posterior Wall (LVPW) as well as the cavity diameter of the Left Ventricle (LVID) and Left Atrium (LAD) are employed for assessing diagnostic value

    SOLID-SHELL FINITE ELEMENT MODELS FOR EXPLICIT SIMULATIONS OF CRACK PROPAGATION IN THIN STRUCTURES

    Get PDF
    Crack propagation in thin shell structures due to cutting is conveniently simulated using explicit finite element approaches, in view of the high nonlinearity of the problem. Solidshell elements are usually preferred for the discretization in the presence of complex material behavior and degradation phenomena such as delamination, since they allow for a correct representation of the thickness geometry. However, in solid-shell elements the small thickness leads to a very high maximum eigenfrequency, which imply very small stable time-steps. A new selective mass scaling technique is proposed to increase the time-step size without affecting accuracy. New ”directional” cohesive interface elements are used in conjunction with selective mass scaling to account for the interaction with a sharp blade in cutting processes of thin ductile shells
    corecore