11,352 research outputs found
Port-Hamiltonian modeling for soft-finger manipulation
In this paper, we present a port-Hamiltonian model of a multi-fingered robotic hand, with soft-pads, while grasping and manipulating an object. The algebraic constraints of the interconnected systems are represented by a geometric object, called Dirac structure. This provides a powerful way to describe the non-contact to contact transition and contact viscoelasticity, by using the concepts of energy flows and power preserving interconnections. Using the port based model, an Intrinsically Passive Controller (IPC) is used to control the internal forces. Simulation results validate the model and demonstrate the effectiveness of the port-based approach
A bistable soft gripper with mechanically embedded sensing and actuation for fast closed-loop grasping
Soft robotic grippers are shown to be high effective for grasping
unstructured objects with simple sensing and control strategies. However, they
are still limited by their speed, sensing capabilities and actuation mechanism.
Hence, their usage have been restricted in highly dynamic grasping tasks. This
paper presents a soft robotic gripper with tunable bistable properties for
sensor-less dynamic grasping. The bistable mechanism allows us to store
arbitrarily large strain energy in the soft system which is then released upon
contact. The mechanism also provides flexibility on the type of actuation
mechanism as the grasping and sensing phase is completely passive. Theoretical
background behind the mechanism is presented with finite element analysis to
provide insights into design parameters. Finally, we experimentally demonstrate
sensor-less dynamic grasping of an unknown object within 0.02 seconds,
including the time to sense and actuate
Design of an Anthropomorphic, Compliant, and Lightweight Dual Arm for Aerial Manipulation
This paper presents an anthropomorphic, compliant and lightweight dual arm manipulator designed and developed for aerial manipulation applications with multi-rotor platforms. Each arm provides four degrees of freedom in a human-like kinematic configuration for end effector positioning: shoulder pitch, roll and yaw, and elbow pitch. The dual arm, weighting 1.3 kg in total, employs smart servo actuators and a customized and carefully designed aluminum frame structure manufactured by laser cut. The proposed
design reduces the manufacturing cost as no computer numerical control machined part is used. Mechanical joint compliance is provided in all the joints, introducing a compact spring-lever transmission mechanism between the servo shaft and the links, integrating a potentiometer for measuring the deflection of the joints.
The servo actuators are partially or fully isolated against impacts and overloads thanks to the ange bearings attached to the frame structure that support the rotation of the links and the deflection of the joints. This simple mechanism increases the robustness of the arms and safety in the physical interactions between the aerial
robot and the environment. The developed manipulator has been validated through different experiments in fixed base test-bench and in outdoor flight tests.Unión Europea H2020-ICT-2014- 644271Ministerio de Economía y Competitividad DPI2015-71524-RMinisterio de Economía y Competitividad DPI2017-89790-
Concept for a large master/slave-controlled robotic hand
A strategy is presented for the design and construction of a large master/slave-controlled, five-finger robotic hand. Each of the five fingers will possess four independent axes each driven by a brushless DC servomotor and, thus, four degrees-of-freedom. It is proposed that commercially available components be utilized as much as possible to fabricate a working laboratory model of the device with an anticipated overall length of two-to-four feet (0.6 to 1.2 m). The fingers are to be designed so that proximity, tactile, or force/torque sensors can be imbedded in their structure. In order to provide for the simultaneous control of the twenty independent hand joints, a multilevel master/slave control strategy is proposed in which the operator wears a specially instrumented glove which produces control signals corresponding to the finger configurations and which is capable of conveying sensor feedback signals to the operator. Two dexterous hand master devices are currently commercially available for this application with both undergoing continuing development. A third approach to be investigated for the master control mode is the use of real-time image processing of a specially patterned master glove to provide the respective control signals for positioning the multiple finger joints
Recommended from our members
Bio-inspired robotic joint and manipulator : from biomechanical experimentation and modeling to human-like compliant finger design and control
textOne of the greatest challenges in controlling robotic hands is grasping and manipulating objects in unstructured and uncertain environments. Robotic hands are typically too rigid to react against unexpected impacts and disturbances in order to prevent damage. The human hands have great versatility and robustness due, in part, to the passive compliance and damping. Designing mechanical elements that are inspired by the nonlinear joint compliance of human hands is a promising solution to achieve human-like grasping and manipulation. However, the exact role of biomechanical elements in realizing joint stiffness is unknown. We conducted a series of experiments to investigate nonlinear stiffness and damping of the metacarpophalangeal (MCP) joint at the index finger. We designed a custom-made mechanism to integrate electromyography sensors (EMGs) and a motion capture system to collect data from 19 subjects. We investigated the relative contributions of muscle-tendon units and the MCP capsule ligament complex to joint stiffness with subject-specific modeling. The results show that the muscle-tendon units provide limited contribution to the passive joint compliance. This findings indicate that the parallel compliance, in the form of the capsule-ligament complex, is significant in defining the passive properties of the hand. To identify the passive damping, we used the hysteresis loops to investigate the energy dissipation function. We used symbolic regression and principal component analysis to derive and interpret the damping models. The results show that the nonlinear viscous damping depends on the cyclic frequency, and fluid and structural types of damping also exist at the MCP joint. Inspired by the nonlinear stiffness of the MCP joint, we developed a miniaturized mechanism that uses pouring liquid plastic to design energy storing elements. The key innovations in this design are: a) a set of nonlinear elasticity of compliant materials, b) variable pulley configurations to tune the stiffness profile, and c) pretension mechanism to scale the stiffness profile. The design exhibits human-like passive compliance. By taking advantage of miniaturized joint size and additive manufacturing, we incorporated the novel joint design in a novel robotic manipulator with six series elastic actuators (SEA). The robotic manipulator has passive joint compliance with the intrinsic property of human hands. To validate the system, we investigated the Cartesian stiffness of grasping with low-level force control. The results show that that the overall system performs a great force tracking with position feedback. The parallel compliance decreases the motor efforts and can stabilize the system.Mechanical Engineerin
a Soft Hand Exoskeleton With a Novel Tendon Layout to Improve Stable Wearing in Grasping Assistance
: We present a novel soft exoskeleton providing active support for hand closing and opening. The main novelty is a different tendon routing, folded laterally on both sides of the hand, and adding clenching forces when the exoskeleton is activated. It improves the stability of the glove, diminishing slippage and detachment of tendons from the hand palm toward the grasping workspace. The clenching effect is released when the hand is relaxed, thus enhancing the user's comfort. The alternative routing allowed embedding a single actuator on the hand dorsum, resulting more compact with no remote cable transmission. Enhanced adaptation to the hand is introduced by the modular design of the soft polymer open rings. FEM simulations were performed to understand the interaction between soft modules and fingers. Different experiments assessed the desired effect of the proposed routing in terms of stability and deformation of the glove, evaluated the inter-finger compliance for non-cylindrical grasping, and characterized the output grasping force. Experiments with subjects explored the grasping performance of the soft exoskeleton with different hand sizes. A preliminary evaluation with Spinal Cord Injury patients was useful to highlight the strengths and limitations of the device when applied to the target scenario
- …