5,571 research outputs found

    USE OF HYBRID DIFFUSE OPTICAL SPECTROSCOPIES IN CONTINUOUS MONITORING OF BLOOD FLOW, BLOOD OXYGENATION, AND OXYGEN CONSUMPTION RATE IN EXERCISING SKELETAL MUSCLE

    Get PDF
    This study combines noninvasive hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] with occlusive calibration for continuous measurement of absolute blood flow (BF), tissue blood oxygenation (StO2), and oxygen consumption rate (VO2) in exercising skeletal muscle. Subjects performed rhythmic dynamic handgrip exercise, while an optical probe connected to a hybrid NIRS/DCS flow-oximeter directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and [tHb]), StO2, relative BF (rBF), and relative VO2 (rVO2) in the forearm flexor muscles. Absolute baseline BF and VO2 were obtained through venous and arterial occlusions, respectively, and used to calibrate continuous relative parameters. Previously known problems with muscle fiber motion artifact in optical measurements were mitigated with a novel dynamometer-based gating algorithm. Nine healthy young subjects were measured and results validated against previous literature findings. Ten older subjects with fibromyalgia and thirteen age-matched healthy controls were then successfully measured to observe differences in hemodynamic and metabolic response to exercise. This study demonstrates a novel application of NIRS/DCS technology to simultaneously evaluate quantitative hemodynamic and metabolic parameters in exercising skeletal muscle. This method has broad application to research and clinical assessment of disease (e.g. peripheral vascular disease, fibromyalgia), treatment evaluation, and sports medicine

    Conduit Artery Photoplethysmography and its Applications in the Assessment of Hemodynamic Condition

    Get PDF
    Elektroniskā versija nesatur pielikumusPromocijas darbā ir izstrādāta maģistrālo artēriju fotopletizmogrāfijas (APPG) metode hemodinamisko parametru novērtējumam. Pretstatot referentām metodēm, demonstrēta iespēja iegūt arteriālo elasticitāti raksturojošus parametrus, izmantojot APPG signāla formas analīzi (atvasinājuma un signāla formas aproksimācijas parametri) un ar APPG iegūtu pulsa izplatīšanās ātrumu unilaterālā gultnē. Izstrādāta APPG reģistrācijas standartizācija, mērījuma laikā nodrošinot optimālo sensora piespiedienu. Šis paņēmiens validēts ārējās ietekmes (sensora piespiediens) un hemodinamisko stāvokļu (perifērā vaskulārā pretestība) izmaiņās femorālā APPG signālā, identificējot būtiskākos faktorus APPG pielietojumos. Veikta APPG validācija asinsrites fizioloģijas un preklīniskā pētījumā demonstrējot APPG potenciālu pētniecībā un diagnostikā. Izstrādāts pulsa formas parametrizācijas paņēmiens, saistot fizioloģiskās un aproksimācijas modeļa komponentes. Atslēgas vārdi: maģistrālā artērija, fotopletizmogrāfija, arteriālā elasticitāte, metodes standartizācija, pulsa formas kvantifikācija, vazomocija, sepseThe doctoral thesis features the development of a conduit artery photoplethysmography technique (APPG) for the evaluation of hemodynamic parameters. Contrasting referent methods, the work demonstrates the possibility to receive parameters characterizing the arterial stiffness by means of APPG waveform analysis (derivation and waveform approximation parameters) and APPG obtained pulse wave velocity in a unilateral vascular bed. In this work APPG standardization technique was developed providing optimal probe contact pressure conditions. It was validated by altering the external factors (probe contact pressure) and hemodynamic conditions (peripheral vascular resistance) on the femoral APPG waveform identifying the key factors in APPG applications. The APPG validation in blood circulation physiology and a pre-clinical trial was performed demonstrating APPG potential in the extension of applications. An arterial waveform parameterization was developed relating the physiological wave to approximation model components. Keywords: conduit artery, photoplethysmography, arterial stiffness, method standardization, waveform parametrization, vasomotion, sepsi

    Assessment of White Matter Hyperintensity, Cerebral Blood Flow, and Cerebral Oxygenation in Older Subjects Stratified by Cerebrovascular Risk

    Get PDF
    Objective: Cerebrovascular disease (CVD) is the fifth most common cause of mortality in the United States. Diagnosis of CVD at an early stage is critical for optimal intervention designed to prevent ongoing and future brain injury. CVD is commonly associated with abnormalities of the cerebral microvasculature leading to tissue dysfunction, neuronal injury and death, and resultant clinical symptoms, which in turn, further impacts cerebral autoregulation (CA). This series of studies aims to test the hypothesis that white matter hyperintensities (WMH) and cerebral hemodynamics (quantified by magnetic resonance imaging (MRI) and an by innovative hybrid near-infrared diffuse optical instrument) can be used as biomarkers to distinguish cognitively healthy older subjects with high or low risk for developing CVD. Methods: Using functional MRI, WMH and cerebral blood flow (CBF) were quantified in 26 cognitively healthy older subjects (age: 77.8 ± 6.8 years). In a follow-up study, significant variability in WMH quantification methodology was addressed, with sources of variability identified in selecting image center of gravity, software compatibility, thresholding techniques, and manual editing procedures. Accordingly, post-acquisition processing methods were optimized to develop a standardized protocol with less than 0.5% inter-rater variance. Using a novel laboratory-made hybrid near-infrared spectroscopy/diffuse correlation spectroscopy (NIRS/DCS) and a finger plethysmograph, low-frequency oscillations (LFOs) of CBF, cerebral oxygenation, and main arterial pressure (MAP) were simultaneously measured before, during, and after 70° head-up-tilting (HUT). Gains (associated with CAs) to magnify LFOs were determined by transfer function analyses with MAP as the input and cerebral hemodynamic parameters as the outputs. In a follow-up study, a fast software correlator for DCS and a parallel detection technique for NIRS/DCS were adapted to improve the sampling rate of hybrid optical measurements. In addition, a new DCS probe was developed to measure CBF at the occipital lobe, which represents a novel application of the NIRS/DCS technique. Results: MRI measurements demonstrate that deep WMH (dWMH) and periventricular WMH (pWMH) volumetric measures are associated with reduced regional cortical CBF in patients at high-risk of CVD. Moreover, CBF in white matter (WM) was reduced in regions demonstrating both pWMH and dWMHs. NIRS/DCS optical measurements demonstrate that at resting baseline, LFO gains in the high-risk group were relatively lower compared to the low-risk group. The lower baseline gains in the high-risk group may be attributed to compensatory mechanisms that allow the maintenance of a stronger steady-state CA. However, HUT resulted in smaller gain reductions in the high-risk group compared to the low-risk group, suggesting weaker dynamic CA in association with increased CVD risks. A noteworthy finding in these experiments was that CVD risk more strongly influenced CBF than cerebral oxygenation. Conclusions: Regional WMH volumes, cortical and WM CBF values, and LFO gains of cerebral hemodynamics demonstrate specific associations with CA and may serve as important potential biomarkers for early diagnosis of CVD. The high spatial resolution, large penetration depth, and variety of imaging-sequences afforded by MRI make it an appealing imaging modality for evaluation of CVD, although MRI is costly, time-limited, and requires transfer of subjects from bed to imaging facility. In contrast, low-cost, portable, mobile diffuse optical technologies provide a complementary alternative for early screening of CVD, that can further allow continuous monitoring of disease attenuation or progression at the subject’s bedside. Thus, development of both methodologies is essential for progress in our future understanding of CVD as a major contributor to the morbidity and mortality associated with CVD today

    STABILIZATION OF EXTENDED DIFFUSE OPTICAL SPECTROSCOPY MEASUREMENTS ON IN VIVO HUMAN SKELETAL MUSCLE DURING DYNAMIC EXERCISE

    Get PDF
    This research investigates various applications of diffuse correlation spectroscopy (DCS) on in-vivo human muscle tissue, both at rest and during dynamic exercise. Previously suspected muscle tissue relative blood flow (rBF) baseline shift during extended measurement with DCS and DCS-Near infrared spectroscopy (NIRS) hybrid optical systems are verified, quantified, and resolved by redesign of optical probe and alteration in optical probe attachment methodology during 40 minute supine bed rest baseline measurements. We then translate previously developed occlusion techniques, whereby rBF and relative oxygen consumption rV̇O2 are calibrated to initial resting absolute values by use of a venous occlusion (VO) and arterial occlusion (AO) protocol, respectively, to the lower leg (gastrocnemius) and these blood flows are cross validated at rest by strain gauge venous plethysmography (SGVP). Methods used to continuously observe 0.5Hz, 30% maximum voluntary isometric contraction (MVIC) plantar flexion exercise via dynamometer are adapted for our hybrid DCS-Imagent diffuse optical flow-oximeter in the medial gastrocnemius. We obtain healthy control muscle tissue hemodynamic profiles for key parameters BF, V̇O2, oxygen saturation (StO2), deoxyhemoglobin, oxyhemoglobin, and total hemoglobin concentrations ([Hb], [HbO2], and THC respectively), as well as systemic mean arterial pressure (MAP) and pulse rate (PR), at rest, during VO/AO, during dynamic exercise and during 15 minute recovery periods. Next, we began investigation of muscle tissue hemodynamic disease states by performing a feasibility pilot study using limited numbers of controls and peripheral arterial disease (PAD) patients using the translated methods/techniques to determine the ability of our technology to assess differences in these populations

    NONINVASIVE MULTIMODAL DIFFUSE OPTICAL IMAGING OF VULNERABLE TISSUE HEMODYNAMICS

    Get PDF
    Measurement of tissue hemodynamics provides vital information for the assessment of tissue viability. This thesis reports three noninvasive near-infrared diffuse optical systems for spectroscopic measurements and tomographic imaging of tissue hemodynamics in vulnerable tissues with the goal of disease diagnosis and treatment monitoring. A hybrid near-infrared spectroscopy/diffuse correlation spectroscopy (NIRS/DCS) instrument with a contact fiber-optic probe was developed and utilized for simultaneous and continuous monitoring of blood flow (BF), blood oxygenation, and oxidative metabolism in exercising gastrocnemius. Results measured by the hybrid NIRS/DCS instrument in 37 subjects (mean age: 67 ± 6) indicated that vitamin D supplement plus aerobic training improved muscle metabolic function in older population. To reduce the interference and potential infection risk on vulnerable tissues caused by the contact measurement, a noncontact diffuse correlation spectroscopy/tomography (ncDCS/ncDCT) system was then developed. The ncDCS/ncDCT system employed optical lenses to project limited numbers of sources and detectors on the tissue surface. A motor-driven noncontact probe scanned over a region of interest to collect boundary data for three dimensional (3D) tomographic imaging of blood flow distribution. The ncDCS was tested for BF measurements in mastectomy skin flaps. Nineteen (19) patients underwent mastectomy and implant-based breast reconstruction were measured before and immediately after mastectomy. The BF index after mastectomy in each patient was normalized to its baseline value before surgery to get relative BF (rBF). Since rBF values in the patients with necrosis (n = 4) were significantly lower than those without necrosis (n = 15), rBF levels can be used to predict mastectomy skin flap necrosis. The ncDCT was tested for 3D imaging of BF distributions in chronic wounds of 5 patients. Spatial variations in BF contrasts over the wounded tissues were observed, indicating the capability of ncDCT in detecting tissue hemodynamic heterogeneities. To improve temporal/spatial resolution and avoid motion artifacts due to a long mechanical scanning of ncDCT, an electron-multiplying charge-coupled device based noncontact speckle contrast diffuse correlation tomography (scDCT) was developed. Validation of scDCT was done by imaging both high and low BF contrasts in tissue-like phantoms and human forearms. In a wound imaging study using scDCT, significant lower BF values were observed in the burned areas/volumes compared to surrounding normal tissues in two patients with burn. One limitation in this study was the potential influence of other unknown tissue optical properties such as tissue absorption coefficient (µa) on BF measurements. A new algorithm was then developed to extract both µa and BF using light intensities and speckle contrasts measured by scDCT at multiple source-detector distances. The new algorithm was validated using tissue-like liquid phantoms with varied values of µa and BF index. In-vivo validation and application of the innovative scDCT technique with the new algorithm is the subject of future work

    Noninvasive monitoring of peripheral perfusion in critically ill patients

    Get PDF

    NONINVASIVE NEAR-INFRARED DIFFUSE OPTICAL MONITORING OF CEREBRAL HEMODYNAMICS AND AUTOREGULATION

    Get PDF
    Many cerebral diseases are associated with abnormal cerebral hemodynamics and impaired cerebral autoregulation (CA). CA is a mechanism to maintain cerebral blood flow (CBF) stable when mean arterial pressure (MAP) fluctuates. Evaluating these abnormalities requires direct measurements of cerebral hemodynamics and MAP. Several near-infrared diffuse optical instruments have been developed in our laboratory for hemodynamic measurements including near-infrared spectroscopy (NIRS), diffuse correlation spectroscopy (DCS), hybrid NIRS/DCS, and dual-wavelength DCS flow-oximeter. We utilized these noninvasive technologies to quantify CBF and cerebral oxygenation in different populations under different physiological conditions/manipulations. A commercial finger plethysmograph was used to continuously monitor MAP. For investigating the impact of obstructive sleep apnea (OSA) on cerebral hemodynamics and CA, a portable DCS device was used to monitor relative changes of CBF (rCBF) during bilateral thigh cuff occlusion. Compared to healthy controls, smaller reductions in rCBF and MAP following cuff deflation were observed in patients with OSA, which might result from the impaired vasodilation. However, dynamic CAs quantified in time-domain (defined by rCBF drop/MAP drop) were not significantly different between the two groups. We also evaluated dynamic CA in frequency-domain, i.e., to quantify the phase shifts of low frequency oscillations (LFOs) at 0.1 Hz between cerebral hemodynamics and MAP under 3 different physiological conditions (i.e., supine resting, head-up tilt (HUT), paced breathing). To capture dynamic LFOs, a hybrid NIRS/DCS device was upgraded to achieve faster sampling rate and better signal-to-noise. We determined the best hemodynamic parameters (i.e., CBF, oxygenated and total hemoglobin concentrations) among the measured variables and optimal physiological condition (HUT) for detecting LFOs in healthy subjects. Finally, a novel dual-wavelength DCS flow-oximeter was developed to monitor cerebral hemodynamics during HUT-induced vasovagal presyncope (VVS) in healthy subjects. rCBF was found to have the best sensitivity for the assessment of VVS among the measured variables and was likely the final trigger of VVS. A threshold of ~50% rCBF decline was observed which can completely separate subjects with or without presyncope, suggesting its potential role for predicting VVS. With further development and applications, NIRS/DCS techniques are expected to have significant impacts on the evaluation of cerebral hemodynamics and autoregulation

    Cerebral Hemodynamics in High-Risk Neonates Probed by Diffuse Optical Spectroscopies

    Get PDF
    Advances in medical and surgical care of the critically ill neonates have decreasedmortality, yet a significant number of these neonates suffer from neurodevelopmentaldelays and failure in school. Thus, clinicians are now focusing on prevention ofneurologic injury and improvement of neurocognitive outcome in these high-risk infants. Assessment of cerebral oxygenation, cerebral blood volume, and the regulation of cerebral blood flow (CBF) during the neonatal period is vital for evaluating brain health. Traditional CBF imaging methods fail, however, for both ethical and logistical reasons. In this dissertation, I demonstrate the use of non-invasive optical modalities, i.e., diffuse optical spectroscopy and diffuse correlation spectroscopy, to study cerebral oxygenation and cerebral blood flow in the critically ill neonatal population. The optical techniques utilize near-infrared (NIR) light to probe the static and dynamic physiological properties of deep tissues. Diffuse correlation spectroscopy (DCS) employs the transport of temporal correlation functions of diffusing light to extract relative changes in blood flow in biological tissues. Diffuse optical spectroscopy (DOS) employs the wavelength-dependent attenuation of NIR light to assess the concentrations of the primary chromophores in the tissue, namely oxy- and deoxy-hemoglobin. This dissertation presents both validation and clinical applications of novel diffuse optical spectroscopies in two specific critically ill neonatal populations: very-low birth weight preterm infants,and infants born with complex congenital heart defects. For validation of DCS in neonates, the blood flow index quantified by DCS is shown to correlate well with velocity measurements in the middle cerebral artery acquired by transcranial Doppler ultrasound. In patients with congenital heart defects DCS-measured relative changes in CBF due to hypercapnia agree strongly with relative changes in blood flow in the jugular veins as measured by phase-encoded velocity mapping magnetic resonance. For applications in the clinic, CO2 reactivity in patients with congenital heart defects prior to various stages of reconstructive surgery was quantified; our initial results suggest that CO2 reactivity is not systematically related to brain injury in this population. Additionally, the cerebral effects of various interventions, such as blood transfusion and sodium bicarbonate infusion, were investigated. In preterm infants, monitoring with DCS reveals a resilience of these patients to maintain constant CBF during a small postural manipulation

    Serum uric acid as a marker of microvascular damage in systemic sclerosis patients

    Get PDF
    Background: Microvascular damage of skin and internal organs is a hallmark of systemic sclerosis (SSc). Serum uric acid (UA) represents a marker of inflammation and endothelial dysfunction. The aims of this study were to evaluate the correlation between serum UA and intrarenal arterial stiffness evaluated by Doppler ultrasound in SSc patients with normal renal function. We also evaluated the correlation between serum UA and other clinical variables of the disease. Methods: Forty-five SSc patients underwent clinical assessment, Doppler ultrasound of intrarenal arteries with evaluation of resistive index (RI), pulsatile index (PI), and systolic/diastolic ratio (S/D), echocardiography with systolic pulmonary artery pressure (PAPs), baseline pulmonary function tests, and nailfold videocapillaroscopy (NVC). In all patients serum UA was measured. Results: The serum UA showed a significant positive correlation with sCr (r = 0.33, p < 0.0001) and PAPs (r = 0.38, p < 0.01) > and negative correlation with CKD-EPI (r = -0.35, p < 0.01). The mean value of serum UA increased with severity of NVC damage. Using this cut-off value of 4.7 mg/dl, the mean value of Doppler indices of intrarenal stiffness is significantly different (p < 0.05) in SSc patients with low normal or high normal serum UA. Conclusions: Serum UA concentration is higher in patients with high microvascular damage than in patients with low microvascular damage. These preliminary data must be confirmed in large prospective studies
    corecore