3,627 research outputs found
Unimanual versus bimanual motor imagery classifiers for assistive and rehabilitative brain computer interfaces
Bimanual movements are an integral part of everyday activities and are often included in rehabilitation therapies. Yet electroencephalography (EEG) based assistive and rehabilitative brain computer interface (BCI) systems typically rely on motor imagination (MI) of one limb at the time. In this study we present a classifier which discriminates between uni-and bimanual MI. Ten able bodied participants took part in cue based motor execution (ME) and MI tasks of the left (L), right (R) and both (B) hands. A 32 channel EEG was recorded. Three linear discriminant analysis classifiers, based on MI of L-B, B-R and B--L hands were created, with features based on wide band Common Spatial Patterns (CSP) 8-30 Hz, and band specifics Common Spatial Patterns (CSPb). Event related desynchronization (ERD) was significantly stronger during bimanual compared to unimanual ME on both hemispheres. Bimanual MI resulted in bilateral parietally shifted ERD of similar intensity to unimanual MI. The average classification accuracy for CSP and CSPb was comparable for L-R task (73±9% and 75±10% respectively) and for L-B task (73±11% and 70±9% respectively). However, for R-B task (67±3% and 72±6% respectively) it was significantly higher for CSPb (p=0.0351). Six participants whose L-R classification accuracy exceeded 70% were included in an on-line task a week later, using the unmodified offline CSPb classifier, achieving 69±3% and 66±3% accuracy for the L-R and R-B tasks respectively. Combined uni and bimanual BCI could be used for restoration of motor function of highly disabled patents and for motor rehabilitation of patients with motor deficits
Converting Your Thoughts to Texts: Enabling Brain Typing via Deep Feature Learning of EEG Signals
An electroencephalography (EEG) based Brain Computer Interface (BCI) enables
people to communicate with the outside world by interpreting the EEG signals of
their brains to interact with devices such as wheelchairs and intelligent
robots. More specifically, motor imagery EEG (MI-EEG), which reflects a
subjects active intent, is attracting increasing attention for a variety of BCI
applications. Accurate classification of MI-EEG signals while essential for
effective operation of BCI systems, is challenging due to the significant noise
inherent in the signals and the lack of informative correlation between the
signals and brain activities. In this paper, we propose a novel deep neural
network based learning framework that affords perceptive insights into the
relationship between the MI-EEG data and brain activities. We design a joint
convolutional recurrent neural network that simultaneously learns robust
high-level feature presentations through low-dimensional dense embeddings from
raw MI-EEG signals. We also employ an Autoencoder layer to eliminate various
artifacts such as background activities. The proposed approach has been
evaluated extensively on a large- scale public MI-EEG dataset and a limited but
easy-to-deploy dataset collected in our lab. The results show that our approach
outperforms a series of baselines and the competitive state-of-the- art
methods, yielding a classification accuracy of 95.53%. The applicability of our
proposed approach is further demonstrated with a practical BCI system for
typing.Comment: 10 page
Translation of EEG spatial filters from resting to motor imagery using independent component analysis.
Electroencephalogram (EEG)-based brain-computer interfaces (BCIs) often use spatial filters to improve signal-to-noise ratio of task-related EEG activities. To obtain robust spatial filters, large amounts of labeled data, which are often expensive and labor-intensive to obtain, need to be collected in a training procedure before online BCI control. Several studies have recently developed zero-training methods using a session-to-session scenario in order to alleviate this problem. To our knowledge, a state-to-state translation, which applies spatial filters derived from one state to another, has never been reported. This study proposes a state-to-state, zero-training method to construct spatial filters for extracting EEG changes induced by motor imagery. Independent component analysis (ICA) was separately applied to the multi-channel EEG in the resting and the motor imagery states to obtain motor-related spatial filters. The resultant spatial filters were then applied to single-trial EEG to differentiate left- and right-hand imagery movements. On a motor imagery dataset collected from nine subjects, comparable classification accuracies were obtained by using ICA-based spatial filters derived from the two states (motor imagery: 87.0%, resting: 85.9%), which were both significantly higher than the accuracy achieved by using monopolar scalp EEG data (80.4%). The proposed method considerably increases the practicality of BCI systems in real-world environments because it is less sensitive to electrode misalignment across different sessions or days and does not require annotated pilot data to derive spatial filters
Brain-Switches for Asynchronous Brain−Computer Interfaces: A Systematic Review
A brain–computer interface (BCI) has been extensively studied to develop a novel communication system for disabled people using their brain activities. An asynchronous BCI system is more realistic and practical than a synchronous BCI system, in that, BCI commands can be generated whenever the user wants. However, the relatively low performance of an asynchronous BCI system is problematic because redundant BCI commands are required to correct false-positive operations. To significantly reduce the number of false-positive operations of an asynchronous BCI system, a two-step approach has been proposed using a brain-switch that first determines whether the user wants to use an asynchronous BCI system before the operation of the asynchronous BCI system. This study presents a systematic review of the state-of-the-art brain-switch techniques and future research directions. To this end, we reviewed brain-switch research articles published from 2000 to 2019 in terms of their (a) neuroimaging modality, (b) paradigm, (c) operation algorithm, and (d) performance
- …