31,954 research outputs found
A detection theory account of change detection
Previous studies have suggested that visual short-term memory (VSTM) has a storage limit of approximately four items. However, the type of high-threshold (HT) model used to derive this estimate is based on a number of assumptions that have been criticized in other experimental paradigms (e.g., visual search). Here we report findings from nine experiments in which VSTM for color, spatial frequency, and orientation was modeled using a signal detection theory (SDT) approach. In Experiments 1-6, two arrays composed of multiple stimulus elements were presented for 100 ms with a 1500 ms ISI. Observers were asked to report in a yes/no fashion whether there was any difference between the first and second arrays, and to rate their confidence in their response on a 1-4 scale. In Experiments 1-3, only one stimulus element difference could occur (T = 1) while set size was varied. In Experiments 4-6, set size was fixed while the number of stimuli that might change was varied (T = 1, 2, 3, and 4). Three general models were tested against the receiver operating characteristics generated by the six experiments. In addition to the HT model, two SDT models were tried: one assuming summation of signals prior to a decision, the other using a max rule. In Experiments 7-9, observers were asked to directly report the relevant feature attribute of a stimulus presented 1500 ms previously, from an array of varying set size. Overall, the results suggest that observers encode stimuli independently and in parallel, and that performance is limited by internal noise, which is a function of set size
Communication channel analysis and real time compressed sensing for high density neural recording devices
Next generation neural recording and Brain-
Machine Interface (BMI) devices call for high density or distributed
systems with more than 1000 recording sites. As the
recording site density grows, the device generates data on the
scale of several hundred megabits per second (Mbps). Transmitting
such large amounts of data induces significant power
consumption and heat dissipation for the implanted electronics.
Facing these constraints, efficient on-chip compression techniques
become essential to the reduction of implanted systems power
consumption. This paper analyzes the communication channel
constraints for high density neural recording devices. This paper
then quantifies the improvement on communication channel
using efficient on-chip compression methods. Finally, This paper
describes a Compressed Sensing (CS) based system that can
reduce the data rate by > 10x times while using power on
the order of a few hundred nW per recording channel
Information Storage and Retrieval for Probe Storage using Optical Diffraction Patterns
A novel method for fast information retrieval from a probe storage device is
considered. It is shown that information can be stored and retrieved using the
optical diffraction patterns obtained by the illumination of a large array of
cantilevers by a monochromatic light source. In thermo-mechanical probe
storage, the information is stored as a sequence of indentations on the polymer
medium. To retrieve the information, the array of probes is actuated by
applying a bending force to the cantilevers. Probes positioned over
indentations experience deflection by the depth of the indentation, probes over
the flat media remain un-deflected. Thus the array of actuated probes can be
viewed as an irregular optical grating, which creates a data-dependent
diffraction pattern when illuminated by laser light. We develop a low
complexity modulation scheme, which allows the extraction of information stored
in the pattern of indentations on the media from Fourier coefficients of the
intensity of the diffraction pattern. We then derive a low-complexity maximum
likelihood sequence detection algorithm for retrieving the user information
from the Fourier coefficients. The derivation of both the modulation and the
detection schemes is based on the Fraunhofer formula for data-dependent
diffraction patterns. We show that for as long as the Fresnel number F<0.1, the
optimal channel detector derived from Fraunhofer diffraction theory does not
suffer any significant performance degradation.Comment: 14 pages, 11 figures. Version 2: minor misprints corrected,
experimental section expande
Mapping our Universe in 3D with MITEoR
Mapping our universe in 3D by imaging the redshifted 21 cm line from neutral
hydrogen has the potential to overtake the cosmic microwave background as our
most powerful cosmological probe, because it can map a much larger volume of
our Universe, shedding new light on the epoch of reionization, inflation, dark
matter, dark energy, and neutrino masses. We report on MITEoR, a pathfinder
low-frequency radio interferometer whose goal is to test technologies that
greatly reduce the cost of such 3D mapping for a given sensitivity. MITEoR
accomplishes this by using massive baseline redundancy both to enable automated
precision calibration and to cut the correlator cost scaling from N^2 to NlogN,
where N is the number of antennas. The success of MITEoR with its 64
dual-polarization elements bodes well for the more ambitious HERA project,
which would incorporate many identical or similar technologies using an order
of magnitude more antennas, each with dramatically larger collecting area.Comment: To be published in proceedings of 2013 IEEE International Symposium
on Phased Array Systems & Technolog
A neural probe with up to 966 electrodes and up to 384 configurable channels in 0.13 μm SOI CMOS
In vivo recording of neural action-potential and local-field-potential signals requires the use of high-resolution penetrating probes. Several international initiatives to better understand the brain are driving technology efforts towards maximizing the number of recording sites while minimizing the neural probe dimensions. We designed and fabricated (0.13-μm SOI Al CMOS) a 384-channel configurable neural probe for large-scale in vivo recording of neural signals. Up to 966 selectable active electrodes were integrated along an implantable shank (70 μm wide, 10 mm long, 20 μm thick), achieving a crosstalk of −64.4 dB. The probe base (5 × 9 mm2) implements dual-band recording and a 1
Integrated control and health management. Orbit transfer rocket engine technology program
To insure controllability of the baseline design for a 7500 pound thrust, 10:1 throttleable, dual expanded cycle, Hydrogen-Oxygen, orbit transfer rocket engine, an Integrated Controls and Health Monitoring concept was developed. This included: (1) Dynamic engine simulations using a TUTSIM derived computer code; (2) analysis of various control methods; (3) Failure Modes Analysis to identify critical sensors; (4) Survey of applicable sensors technology; and, (5) Study of Health Monitoring philosophies. The engine design was found to be controllable over the full throttling range by using 13 valves, including an oxygen turbine bypass valve to control mixture ratio, and a hydrogen turbine bypass valve, used in conjunction with the oxygen bypass to control thrust. Classic feedback control methods are proposed along with specific requirements for valves, sensors, and the controller. Expanding on the control system, a Health Monitoring system is proposed including suggested computing methods and the following recommended sensors: (1) Fiber optic and silicon bearing deflectometers; (2) Capacitive shaft displacement sensors; and (3) Hot spot thermocouple arrays. Further work is needed to refine and verify the dynamic simulations and control algorithms, to advance sensor capabilities, and to develop the Health Monitoring computational methods
Linear laser diode arrays for improvement in optical disk recording for space stations
The design and fabrication of individually addressable laser diode arrays for high performance magneto-optic recording systems are presented. Ten diode arrays with 30 mW cW light output, linear light vs. current characteristics and single longitudinal mode spectrum were fabricated using channel substrate planar (CSP) structures. Preliminary results on the inverse CSP structure, whose fabrication is less critically dependent on device parameters than the CSP, are also presented. The impact of systems parameters and requirements, in particular, the effect of feedback on laser design is assessed, and techniques to reduce feedback or minimize its effect on systems performance, including mode-stabilized structures, are evaluated
DNA multi-bit non-volatile memory and bit-shifting operations using addressable electrode arrays and electric field-induced hybridization.
DNA has been employed to either store digital information or to perform parallel molecular computing. Relatively unexplored is the ability to combine DNA-based memory and logical operations in a single platform. Here, we show a DNA tri-level cell non-volatile memory system capable of parallel random-access writing of memory and bit shifting operations. A microchip with an array of individually addressable electrodes was employed to enable random access of the memory cells using electric fields. Three segments on a DNA template molecule were used to encode three data bits. Rapid writing of data bits was enabled by electric field-induced hybridization of fluorescently labeled complementary probes and the data bits were read by fluorescence imaging. We demonstrated the rapid parallel writing and reading of 8 (23) combinations of 3-bit memory data and bit shifting operations by electric field-induced strand displacement. Our system may find potential applications in DNA-based memory and computations
- …