435,018 research outputs found
Quantum broadcast communication
Broadcast encryption allows the sender to securely distribute his/her secret
to a dynamically changing group of users over a broadcast channel. In this
paper, we just consider a simple broadcast communication task in quantum
scenario, which the central party broadcasts his secret to multi-receiver via
quantum channel. We present three quantum broadcast communication schemes. The
first scheme utilizes entanglement swapping and Greenberger-Horne-Zeilinger
state to realize a task that the central party broadcasts his secret to a group
of receivers who share a group key with him. In the second scheme, based on
dense coding, the central party broadcasts the secret to multi-receiver who
share each of their authentication key with him. The third scheme is a quantum
broadcast communication scheme with quantum encryption, which the central party
can broadcast the secret to any subset of the legal receivers
Central Monitor Based on Personal Computer Using One Wireless Receiver
Central monitor is a tool in the health field that serves to monitor the patient's condition which is centralized in one monitor display centrally. In this scientific paper raised wireless systems for sending data to one monitor. In this module there are Electrocardiograph (EKG) parameters which are a parameter to detect and measure the electrical activity of the heart muscle using measurements of biopotential signals obtained from the surface of the body. From these measurements, an ECG signal will be obtained to produce a heart rate per minute (BPM). ECG signals are obtained from measurements of the electrical activity of the heart through electrodes placed on the patient's skin using the bipolar lead method. ECG signals will be processed using a microcontroller circuit as processors. Then the data will be sent to the PC using wireless HC-11. The data received by the PC, then processed using the Delphi application which will then display ECG charts and BPM results and abnormalities indicators if the BPM is in a condition above or below normal. By comparing the module with a standard measuring instrument, the biggest error is 0.99% which is still in tolerance because the tolerance limit is 5
Solar thermal power systems point-focusing thermal and electric applications projects. Volume 1: Executive summary
The activities of the Point-Focusing Thermal and Electric Applications (PETEA) project for the fiscal year 1979 are summarized. The main thrust of the PFTEA Project, the small community solar thermal power experiment, was completed. Concept definition studies included a small central receiver approach, a point-focusing distributed receiver system with central power generation, and a point-focusing distributed receiver concept with distributed power generation. The first experiment in the Isolated Application Series was initiated. Planning for the third engineering experiment series, which addresses the industrial market sector, was also initiated. In addition to the experiment-related activities, several contracts to industry were let and studies were conducted to explore the market potential for point-focusing distributed receiver (PFDR) systems. System analysis studies were completed that looked at PFDR technology relative to other small power system technology candidates for the utility market sector
Central limit theorem for signal-to-interference ratio of reduced rank linear receiver
Let with
independent and identically distributed complex random
variables. Write ,
and
. Define
$\beta_{km}=p_k\mathbf{s}_k^*\mathbf{A}_{km}(\mathbf {A}_{km}^*\times\
mathbf{R}_k\mathbf{A}_{km})^{-1}\mathbf{A}_{km}^*\mathbf{s}_kkN/K\to c>0$. Moreover, we provide a
central limit theorem for linear spectral statistics of eigenvalues and
eigenvectors of sample covariance matrices, which is a supplement of Theorem 2
in Bai, Miao and Pan [Ann. Probab. 35 (2007) 1532--1572]. And we also improve
Theorem 1.1 in Bai and Silverstein [Ann. Probab. 32 (2004) 553--605].Comment: Published in at http://dx.doi.org/10.1214/07-AAP477 the Annals of
Applied Probability (http://www.imstat.org/aap/) by the Institute of
Mathematical Statistics (http://www.imstat.org
The Atacama Cosmology Telescope: The polarization-sensitive ACTPol instrument
The Atacama Cosmology Telescope (ACT) is designed to make high angular
resolution measurements of anisotropies in the Cosmic Microwave Background
(CMB) at millimeter wavelengths. We describe ACTPol, an upgraded receiver for
ACT, which uses feedhorn-coupled, polarization-sensitive detector arrays, a 3
degree field of view, 100 mK cryogenics with continuous cooling, and meta
material anti-reflection coatings. ACTPol comprises three arrays with separate
cryogenic optics: two arrays at a central frequency of 148 GHz and one array
operating simultaneously at both 97 GHz and 148 GHz. The combined instrument
sensitivity, angular resolution, and sky coverage are optimized for measuring
angular power spectra, clusters via the thermal Sunyaev-Zel'dovich and kinetic
Sunyaev-Zel'dovich signals, and CMB lensing due to large scale structure. The
receiver was commissioned with its first 148 GHz array in 2013, observed with
both 148 GHz arrays in 2014, and has recently completed its first full season
of operations with the full suite of three arrays. This paper provides an
overview of the design and initial performance of the receiver and related
systems
Signal-Aligned Network Coding in K-User MIMO Interference Channels with Limited Receiver Cooperation
In this paper, we propose a signal-aligned network coding (SNC) scheme for
K-user time-varying multiple-input multiple-output (MIMO) interference channels
with limited receiver cooperation. We assume that the receivers are connected
to a central processor via wired cooperation links with individual limited
capacities. Our SNC scheme determines the precoding matrices of the
transmitters so that the transmitted signals are aligned at each receiver. The
aligned signals are then decoded into noiseless integer combinations of
messages, also known as network-coded messages, by physical-layer network
coding. The key idea of our scheme is to ensure that independent integer
combinations of messages can be decoded at the receivers. Hence the central
processor can recover the original messages of the transmitters by solving the
linearly independent equations. We prove that our SNC scheme achieves full
degrees of freedom (DoF) by utilizing signal alignment and physical-layer
network coding. Simulation results show that our SNC scheme outperforms the
compute-and-forward scheme in the finite SNR regime of the two-user and the
three-user cases. The performance improvement of our SNC scheme mainly comes
from efficient utilization of the signal subspaces for conveying independent
linear equations of messages to the central processor.Comment: 12 pages, 4 figures, submitted to the IEEE Transactions on Vehicular
Technolog
Improving the accuracy of 1D SNMR surveys using the multi-central-loop configuration
A multi-central loop configuration has been studied through forward and inverse modelling of synthetics and real data. This set-up takes advantage of the multichannel features of the NMR device and consists of using several (2 to 3) additional receiver loops displayed concentrically with the main transmitter/receiver loop, which all record the NMR signal simultaneously within a single acquisition. If the loop diameters are chosen appropriately, the kernel sensitivity distributions for each receiver loop can show complementary features. Inverting simultaneously the data sets obtained through each different receiver loop can then enhance the accuracy of the final model. To do so, a 1D QT inversion scheme in the frequency domain dedicated to the inversion of multiple data sets is being used. One challenging feature is to adapt the regularization of the inverse process so as to handle correctly the noise originating from different data sets. The efficiency of this multi-central loop acquisition set-up and procedure is being assessed through the forward and inverse modelling of several scenarios implying varying aquifer characteristics. Finally a field case is being presented that was conducted on a low noise level site located in Germany, where conditions were favourable to the implementation and testing of circular multi-central loop configurations.We also introduce a new method for determining NMR parameters, named the prediction-focused-approach (PFA), that is based on statistical analysis of a large number of simple models. We observe, using synthetic examples, that the effciency of the method benefits from the use of the multi-central-loop configurations
Solar thermal technology evaluation, fiscal year 1982. Volume 1: Executive summary
Three primary solar concepts the central receiver, parabolic dish, and parabolic trough are investigated. To a lesser extent, the hemispherical bowl and salt-gradient solar pond are also being studied. Each technology is described
Spatial frequency response of an optical heterodyne receiver
The principles of transfer function analysis are applied to a passive optical heterodyne receiver to obtain the modulation transfer function (MTF). MTF calculations are performed based on an optical platform which is imaging vertically varying profiles at worst case shuttle orbit altitudes. An analysis of the derogatory effects of sampling (aliasing) and central obscurations on both resolution and heterodyne efficiency is given. It is found that the cascading property of MTF analysis must be carefully applied since the coherent transfer function of the optical receiver and that due to the local oscillator-detector combination are not separable but are related by the convolution of their products. Application of these results to the specific case of a space-lab type optical heterodyne receiver shows that resolutions of the order of 1.5-2.0 Km are possible for worst-case type orbital scenarios. Further, comparison of obscured-type receivers (e.g., Cassegrains) with unobscured receivers shows that both resolution and efficiency are severely degraded in an obscured-type receiver and consequently should not be used for a passive heterodyne detection scheme
- …
