169 research outputs found

    Cold atom Clocks and Applications

    Full text link
    This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the 133^{133}Cs and 87^{87}Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of 1.6×10−14τ−1/21.6\times 10^{-14}\tau^{-1/2} where τ\tau is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2×10−162\times 10^{-16} at 50,000sforthefirsttimeforprimarystandards.Inaddition,theseclocksrealizetheSIsecondwithanaccuracyof50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7\times 10^{-16},oneorderofmagnitudebelowthatofuncooleddevices.Inasecondpart,wedescribetestsofpossiblevariationsoffundamentalconstantsusing, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using ^{87}RbandRb and ^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.Comment: 30 pages, 11 figure

    Progress in Atomic Fountains at LNE-SYRTE

    Full text link
    We give an overview of the work done with the Laboratoire National de M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.Comment: 19 pages, 12 figures, 5 tables, 126 reference

    A Search for Variations of Fundamental Constants using Atomic Fountain Clocks

    Get PDF
    Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.Comment: 4 pages, 3 figures, 1 table submitted to Phys. Rev. Let

    Cancellation of the collisional frequency shift in caesium fountain clocks

    Get PDF
    We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F = 4, mF = 0> atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in the performance of caesium fountain standards and a simplification in their operation. Our results also have implications for test operation of fountains at multiple pi/2 pulse areas

    First Accuracy Evaluation of NIST-F2

    Get PDF
    We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled Cesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (Liquid Nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the Blackbody Radiation (BBR) shift by more than a factor of 50. Also, the Ramsey microwave cavity exhibits a high Q (>50,000) at this low temperature, resulting in a reduced distributed cavity phase shift. NIST-F2 has undergone many tests and improvements since we first began operation in 2008. In the last few years NIST-F2 has been compared against a NIST maser time scale and NIST-F1 (the US primary frequency standard) as part of in-house accuracy evaluations. We report the results of nine in-house comparisons since 2010 with a focus on the most recent accuracy evaluation. This paper discusses the design of the physics package, the laser and optics systems, and the accuracy evaluation methods. The Type B fractional uncertainty of NIST-F2 is shown to be 0.11 × 10-15 and is dominated by microwave amplitude dependent effects. The most recent evaluation (August 2013) had a statistical (Type A) fractional uncertainty of 0.44 × 10-15

    Controlling the cold collision shift in high precision atomic interferometry

    Get PDF
    We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the 10−1610^{-16} level realistic. With an improved set-up, the adiabatic passage would allow measurements of atom number-dependent phase shifts at the 10−310^{-3} level in high precision experiments.Comment: 4 pages, 3 figures, 2 table
    • 

    corecore