169 research outputs found
Cold atom Clocks and Applications
This paper describes advances in microwave frequency standards using
laser-cooled atoms at BNM-SYRTE. First, recent improvements of the Cs
and Rb atomic fountains are described. Thanks to the routine use of a
cryogenic sapphire oscillator as an ultra-stable local frequency reference, a
fountain frequency instability of where
is the measurement time in seconds is measured. The second advance is a
powerful method to control the frequency shift due to cold collisions. These
two advances lead to a frequency stability of at 7\times 10^{-16}^{87}^{133}$Cs fountains.
Finally we give an update on the cold atom space clock PHARAO developed in
collaboration with CNES. This clock is one of the main instruments of the
ACES/ESA mission which is scheduled to fly on board the International Space
Station in 2008, enabling a new generation of relativity tests.Comment: 30 pages, 11 figure
Progress in Atomic Fountains at LNE-SYRTE
We give an overview of the work done with the Laboratoire National de
M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE)
fountain ensemble during the last five years. After a description of the clock
ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest
developments, we review recent studies of several systematic frequency shifts.
This includes the distributed cavity phase shift, which we evaluate for the FO1
and FOM fountains, applying the techniques of our recent work on FO2. We also
report calculations of the microwave lensing frequency shift for the three
fountains, review the status of the blackbody radiation shift, and summarize
recent experimental work to control microwave leakage and spurious phase
perturbations. We give current accuracy budgets. We also describe several
applications in time and frequency metrology: fountain comparisons,
calibrations of the international atomic time, secondary representation of the
SI second based on the 87Rb hyperfine frequency, absolute measurements of
optical frequencies, tests of the T2L2 satellite laser link, and review
fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally,
we give a summary of the tests of the PHARAO cold atom space clock performed
using the FOM transportable fountain.Comment: 19 pages, 12 figures, 5 tables, 126 reference
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb
atoms in their electronic ground state using several laser cooled 133Cs and
87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a
stringent upper bound to a possible fractional time variation of the ratio
between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16}
yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation
of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of
nuclear magnetic moments and the fine structure constant.Comment: 4 pages, 3 figures, 1 table submitted to Phys. Rev. Let
Cancellation of the collisional frequency shift in caesium fountain clocks
We have observed that the collisional frequency shift in primary caesium
fountain clocks varies with the clock state population composition and, in
particular, is zero for a given fraction of the |F = 4, mF = 0> atoms,
depending on the initial cloud parameters. We present a theoretical model
explaining our observations. The possibility of the collisional shift
cancellation implies an improvement in the performance of caesium fountain
standards and a simplification in their operation. Our results also have
implications for test operation of fountains at multiple pi/2 pulse areas
First Accuracy Evaluation of NIST-F2
We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled Cesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (Liquid Nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the Blackbody Radiation (BBR) shift by more than a factor of 50. Also, the Ramsey microwave cavity exhibits a high Q (>50,000) at this low temperature, resulting in a reduced distributed cavity phase shift. NIST-F2 has undergone many tests and improvements since we first began operation in 2008. In the last few years NIST-F2 has been compared against a NIST maser time scale and NIST-F1 (the US primary frequency standard) as part of in-house accuracy evaluations. We report the results of nine in-house comparisons since 2010 with a focus on the most recent accuracy evaluation. This paper discusses the design of the physics package, the laser and optics systems, and the accuracy evaluation methods. The Type B fractional uncertainty of NIST-F2 is shown to be 0.11 Ă 10-15 and is dominated by microwave amplitude dependent effects. The most recent evaluation (August 2013) had a statistical (Type A) fractional uncertainty of 0.44 Ă 10-15
Controlling the cold collision shift in high precision atomic interferometry
We present here a new method based on a transfer of population by adiabatic
passage that allows to prepare cold atomic samples with a well defined ratio of
atomic density and atom number. This method is used to perform a measurement of
the cold collision frequency shift in a laser cooled cesium clock at the
percent level, which makes the evaluation of the cesium fountains accuracy at
the level realistic. With an improved set-up, the adiabatic passage
would allow measurements of atom number-dependent phase shifts at the
level in high precision experiments.Comment: 4 pages, 3 figures, 2 table
- âŠ