4 research outputs found

    A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma

    Get PDF
    ntroduction In clinical practice, it is difficult to distinguish between patients with refractory asthma from those with poorly controlled asthma, where symptoms persist due to poor adherence, inadequate inhaler technique or comorbid diseases. We designed an audio recording device which, when attached to an inhaler, objectively identifies the time and technique of inhaler use, thereby assessing both aspects of adherence. This study will test the hypothesis that feedback on these two aspects of adherence when passed on to patients improves adherence and helps clinicians distinguish refractory from difficult-to-control asthma. Methods This is a single, blind, prospective, randomised, clinical trial performed at 5 research centres. Patients with partially controlled or uncontrolled severe asthma who have also had at least one severe asthma exacerbation in the prior year are eligible to participate. The effect of two types of nurse-delivered education interventions to promote adherence and inhaler technique will be assessed. The active group will receive feedback on their inhaler technique and adherence from the new device over a 3-month period. The control group will also receive training in inhaler technique and strategies to promote adherence, but no feedback from the device. The primary outcome is the difference in actual adherence, a measure that incorporates time and technique of inhaler use between groups at the end of the third month. Secondary outcomes include the number of patients who remain refractory despite good adherence, and differences in the components of adherence after the intervention. Data will be analysed on an intention-to-treat and a per-protocol basis. The sample size is 220 subjects (110 in each group), and loss to follow-up is estimated at 10% which will allow results to show a 10% difference (0.8 power) in adherence between group means with a type I error probability of 0.05. Trial registration number NCT01529697; Pre-results

    An Inhaler Tracking System Based on Acoustic Analysis:Hardware and Software

    Get PDF
    In treating asthma and chronic obstructive pulmonary disorder (COPD), acquisition of authentic and effective feedback from patients on regimen adherence is difficult. Face-to-face and oral reporting methods do not satisfy current intelligent medication best practices. This paper presents a system to track and analyze daily inhaler usage. A portable electronic device that attaches to the inhaler uses an accelerometer and capacitive sensors to detect users’ motion and an embedded digital microphone to capture sounds while the inhaler is in use. In terms of analysis, sound features are extracted, and breath phases are identified by employing a hidden Markov model with a Gaussian mixture model. A feature template is also constructed and used to search for and identify “canister pressed” events. The system provides objective feedback, quantifying asthma, and COPD patients’ adherence to medication regimens. Although interest in asthma adherence to medication regimens is growing, there is still a relative paucity of research and, indeed, compliance devices in this area; the tracking system can help doctors better understand the patient’s condition and choose an appropriated treatment plan. At the same time, patients can also improve their self-management by system feedback

    In patients with severe uncontrolled asthma, does knowledge of adherence and inhaler technique using electronic monitoring improve clinical decision making? A protocol for a randomised controlled trial

    Get PDF
    Introduction: Many patients with asthma remain poorly controlled despite the use of inhaled corticosteroids and long-acting beta agonists. Poor control may arise from inadequate adherence, incorrect inhaler technique or because the condition is refractory. Without having an objective assessment of adherence, clinicians may inadvertently add extra medication instead of addressing adherence. This study aims to assess if incorporating objectively recorded adherence from the Inhaler Compliance Assessment (INCA) device and lung function into clinical decision making provides more cost-effective prescribing and improves outcomes. Methods and analysis: This prospective, randomised, multicentre study will compare the impact of using information on adherence to influence asthma treatment. Patients with severe uncontrolled asthma will be included. Data on adherence, inhaler technique and electronically recorded peak expiratory flow rate will be used to promote adherence and guide a clinical decision protocol to guide management in the active group. The control group will receive standard inhaler and adherence education. Medications will be adjusted using a protocol based on Global Initiativefor Asthma (GINA) recommendations. The primary outcome is the between-group difference in the proportion of patients who have refractory disease and are prescribed appropriate medications at the end of 32 weeks. A co-primary outcome is the difference between groups in the rate of adherence to salmeterol/fluticasone inhaler over the last 12 weeks. Secondary outcomes include changes in symptoms, lung function, type-2 cytokine biomarkers and clinical outcomes between both groups. Cost-effectiveness and cost-utility analyses of the INCA device intervention will be performed. The economic impact of a national implementation of the INCA-SUN programme will be evaluated. Ethics and dissemination:The results of the study will be published as a manuscript in peer-reviewed journals. The study has been approved by the ethics committees in the five participating hospitals. Trial registration NCT02307669; Pre-results

    Objective Assessment of Adherence to Inhalers by COPD Patients.

    Get PDF
    RATIONALE: Objective adherence to inhaled therapy by patients with COPD has not been reported. OBJECTIVES: The aim of this study was to objectively quantify adherence to preventer DiskusTM inhaler therapy by patients with COPD with an electronic audio recording device (INCATM). METHODS: This was a prospective observational study. On discharge from hospital patients were given a salmeterol/fluticasone inhaler with an INCATM device attached. Analysis of this audio quantified the frequency and proficiency of inhaler use. MEASUREMENTS AND MAIN RESULTS: COPD patients (n=265) were recruited. The mean age 71 years, mean Forced Expiratory Volume in 1-second 1.3 Litres, and 80% had evidence of mild/moderate cognitive impairment. By combining time of use, interval between doses and critical technique errors, thus incorporating both intentional and unintentional non-adherence, a measure \u22Actual Adherence\u22 was calculated. Mean Actual Adherence was 22.9% of that expected if the doses were taken correctly and on time. Seven percent had an Actual Adherence\u3e80%. Hierarchical clustering found three equally sized well-separated clusters corresponding to distinct patterns: Cluster 1 (34%) had low inhaler use and high error rates, Cluster 2 (31%) had high inhaler use and high error rates, and Cluster 3 (30%) had overall good adherence. Lung function and co-morbidities were predictive of poor technique, while age and cognition with poor lung function distinguished those with poor adherence and frequent errors in technique. CONCLUSION: These data may inform clinicians both in understanding why a prescribed inhaler is not effective and to devise strategies to promote adherence in COPD