4,915 research outputs found

    Automatic roI detection for camera-based pulse-rate measurement

    Get PDF
    Remote photoplethysmography (rPPG) enables contactless measurement of pulse-rate by detecting pulse-induced colour changes on human skin using a regular camera. Most of existing rPPG methods exploit the subject face as the Region of Interest (RoI) for pulse-rate measurement by automatic face detection. However, face detection is a suboptimal solution since (1) not all the subregions in a face contain the skin pixels where pulse-signal can be extracted, (2) it fails to locate the RoI in cases when the frontal face is invisible (e.g., side-view faces). In this paper, we present a novel automatic RoI detection method for camerabased pulse-rate measurement, which consists of three main steps: subregion tracking, feature extraction, and clustering of skin regions. To evaluate the robustness of the proposed method, 36 video recordings are made of 6 subjects with different skin-types performing 6 types of head motion. Experimental results show that for the video sequences containing subjects with brighter skin-types and modest body motions, the accuracy of the pulse-rates measured by our method (94 %) is comparable to that obtained by a face detector (92 %), while the average SNR is significantly improved from 5.8 dB to 8.6 dB

    DistancePPG: Robust non-contact vital signs monitoring using a camera

    Full text link
    Vital signs such as pulse rate and breathing rate are currently measured using contact probes. But, non-contact methods for measuring vital signs are desirable both in hospital settings (e.g. in NICU) and for ubiquitous in-situ health tracking (e.g. on mobile phone and computers with webcams). Recently, camera-based non-contact vital sign monitoring have been shown to be feasible. However, camera-based vital sign monitoring is challenging for people with darker skin tone, under low lighting conditions, and/or during movement of an individual in front of the camera. In this paper, we propose distancePPG, a new camera-based vital sign estimation algorithm which addresses these challenges. DistancePPG proposes a new method of combining skin-color change signals from different tracked regions of the face using a weighted average, where the weights depend on the blood perfusion and incident light intensity in the region, to improve the signal-to-noise ratio (SNR) of camera-based estimate. One of our key contributions is a new automatic method for determining the weights based only on the video recording of the subject. The gains in SNR of camera-based PPG estimated using distancePPG translate into reduction of the error in vital sign estimation, and thus expand the scope of camera-based vital sign monitoring to potentially challenging scenarios. Further, a dataset will be released, comprising of synchronized video recordings of face and pulse oximeter based ground truth recordings from the earlobe for people with different skin tones, under different lighting conditions and for various motion scenarios.Comment: 24 pages, 11 figure

    Estimating Carotid Pulse and Breathing Rate from Near-infrared Video of the Neck

    Full text link
    Objective: Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and ballistocardiographic signals can be easily analyzed and/or require expensive and custom hardware to perform the measurements. Approach: This work introduces a low-cost method to measure subtle motions associated with the carotid pulse and breathing movement from the neck using near-infrared (NIR) video imaging. A skin reflection model of the neck was established to provide a theoretical foundation for the method. In particular, the method relies on template matching for neck detection, Principal Component Analysis for feature extraction, and Hidden Markov Models for data smoothing. Main Results: We compared the estimated HR and BR measures with ones provided by an FDA-cleared device in a 12-participant laboratory study: the estimates achieved a mean absolute error of 0.36 beats per minute and 0.24 breaths per minute under both bright and dark lighting. Significance: This work advances the possibilities of non-contact physiological measurement in real-life conditions in which environmental illumination is limited and in which the face of the person is not readily available or needs to be protected. Due to the increasing availability of NIR imaging devices, the described methods are readily scalable.Comment: 21 pages, 15 figure

    A Comparative Evaluation of Heart Rate Estimation Methods using Face Videos

    Full text link
    This paper presents a comparative evaluation of methods for remote heart rate estimation using face videos, i.e., given a video sequence of the face as input, methods to process it to obtain a robust estimation of the subjects heart rate at each moment. Four alternatives from the literature are tested, three based in hand crafted approaches and one based on deep learning. The methods are compared using RGB videos from the COHFACE database. Experiments show that the learning-based method achieves much better accuracy than the hand crafted ones. The low error rate achieved by the learning based model makes possible its application in real scenarios, e.g. in medical or sports environments.Comment: Accepted in "IEEE International Workshop on Medical Computing (MediComp) 2020

    Measurement of retinal vessel widths from fundus images based on 2-D modeling

    Get PDF
    Changes in retinal vessel diameter are an important sign of diseases such as hypertension, arteriosclerosis and diabetes mellitus. Obtaining precise measurements of vascular widths is a critical and demanding process in automated retinal image analysis as the typical vessel is only a few pixels wide. This paper presents an algorithm to measure the vessel diameter to subpixel accuracy. The diameter measurement is based on a two-dimensional difference of Gaussian model, which is optimized to fit a two-dimensional intensity vessel segment. The performance of the method is evaluated against Brinchmann-Hansen's half height, Gregson's rectangular profile and Zhou's Gaussian model. Results from 100 sample profiles show that the presented algorithm is over 30% more precise than the compared techniques and is accurate to a third of a pixel

    Analysis of Noncontact Heartbeat Detection

    Get PDF
    [[sponsorship]]IEEE[[conferencetype]]國際[[conferencedate]]20150606~20150608[[booktype]]電子版[[iscallforpapers]]Y[[conferencelocation]]台灣/台北 國立臺灣科技大
    corecore