2,980 research outputs found

    Arterial mechanical motion estimation based on a semi-rigid body deformation approach

    Get PDF
    Arterial motion estimation in ultrasound (US) sequences is a hard task due to noise and discontinuities in the signal derived from US artifacts. Characterizing the mechanical properties of the artery is a promising novel imaging technique to diagnose various cardiovascular pathologies and a new way of obtaining relevant clinical information, such as determining the absence of dicrotic peak, estimating the Augmentation Index (AIx), the arterial pressure or the arterial stiffness. One of the advantages of using US imaging is the non-invasive nature of the technique unlike Intra Vascular Ultra Sound (IVUS) or angiography invasive techniques, plus the relative low cost of the US units. In this paper, we propose a semi rigid deformable method based on Soft Bodies dynamics realized by a hybrid motion approach based on cross-correlation and optical flow methods to quantify the elasticity of the artery. We evaluate and compare different techniques (for instance optical flow methods) on which our approach is based. The goal of this comparative study is to identify the best model to be used and the impact of the accuracy of these different stages in the proposed method. To this end, an exhaustive assessment has been conducted in order to decide which model is the most appropriate for registering the variation of the arterial diameter over time. Our experiments involved a total of 1620 evaluations within nine simulated sequences of 84 frames each and the estimation of four error metrics. We conclude that our proposed approach obtains approximately 2.5 times higher accuracy than conventional state-of-the-art techniques.The authors thank Ana Palomares for revising their English text. This work has been supported by the National Grant (AP2007-00275), the projects ARC-VISION (TEC2010-15396), ITREBA (TIC-5060), and the EU project TOMSY (FP7-270436)

    Immersed boundary-finite element model of fluid-structure interaction in the aortic root

    Get PDF
    It has long been recognized that aortic root elasticity helps to ensure efficient aortic valve closure, but our understanding of the functional importance of the elasticity and geometry of the aortic root continues to evolve as increasingly detailed in vivo imaging data become available. Herein, we describe fluid-structure interaction models of the aortic root, including the aortic valve leaflets, the sinuses of Valsalva, the aortic annulus, and the sinotubular junction, that employ a version of Peskin's immersed boundary (IB) method with a finite element (FE) description of the structural elasticity. We develop both an idealized model of the root with three-fold symmetry of the aortic sinuses and valve leaflets, and a more realistic model that accounts for the differences in the sizes of the left, right, and noncoronary sinuses and corresponding valve cusps. As in earlier work, we use fiber-based models of the valve leaflets, but this study extends earlier IB models of the aortic root by employing incompressible hyperelastic models of the mechanics of the sinuses and ascending aorta using a constitutive law fit to experimental data from human aortic root tissue. In vivo pressure loading is accounted for by a backwards displacement method that determines the unloaded configurations of the root models. Our models yield realistic cardiac output at physiological pressures, with low transvalvular pressure differences during forward flow, minimal regurgitation during valve closure, and realistic pressure loads when the valve is closed during diastole. Further, results from high-resolution computations demonstrate that IB models of the aortic valve are able to produce essentially grid-converged dynamics at practical grid spacings for the high-Reynolds number flows of the aortic root

    Numerical simulation of blood flow and vessel wall stresses in stenosed arteries

    Get PDF

    Book of Abstracts 15th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering and 3rd Conference on Imaging and Visualization

    Get PDF
    In this edition, the two events will run together as a single conference, highlighting the strong connection with the Taylor & Francis journals: Computer Methods in Biomechanics and Biomedical Engineering (John Middleton and Christopher Jacobs, Eds.) and Computer Methods in Biomechanics and Biomedical Engineering: Imaging and Visualization (JoãoManuel R.S. Tavares, Ed.). The conference has become a major international meeting on computational biomechanics, imaging andvisualization. In this edition, the main program includes 212 presentations. In addition, sixteen renowned researchers will give plenary keynotes, addressing current challenges in computational biomechanics and biomedical imaging. In Lisbon, for the first time, a session dedicated to award the winner of the Best Paper in CMBBE Journal will take place. We believe that CMBBE2018 will have a strong impact on the development of computational biomechanics and biomedical imaging and visualization, identifying emerging areas of research and promoting the collaboration and networking between participants. This impact is evidenced through the well-known research groups, commercial companies and scientific organizations, who continue to support and sponsor the CMBBE meeting series. In fact, the conference is enriched with five workshops on specific scientific topics and commercial software.info:eu-repo/semantics/draf

    Preoperative Systems for Computer Aided Diagnosis based on Image Registration: Applications to Breast Cancer and Atherosclerosis

    Get PDF
    Computer Aided Diagnosis (CAD) systems assist clinicians including radiologists and cardiologists to detect abnormalities and highlight conspicuous possible disease. Implementing a pre-operative CAD system contains a framework that accepts related technical as well as clinical parameters as input by analyzing the predefined method and demonstrates the prospective output. In this work we developed the Computer Aided Diagnostic System for biomedical imaging analysis of two applications on Breast Cancer and Atherosclerosis. The aim of the first CAD application is to optimize the registration strategy specifically for Breast Dynamic Infrared Imaging and to make it user-independent. Base on the fact that automated motion reduction in dynamic infrared imaging is on demand in clinical applications, since movement disarranges time-temperature series of each pixel, thus originating thermal artifacts that might bias the clinical decision. All previously proposed registration methods are feature based algorithms requiring manual intervention. We implemented and evaluated 3 different 3D time-series registration methods: 1. Linear affine, 2. Non-linear Bspline, 3. Demons applied to 12 datasets of healthy breast thermal images. The results are evaluated through normalized mutual information with average values of 0.70±0.03, 0.74±0.03 and 0.81±0.09 (out of 1) for Affine, BSpline and Demons registration, respectively, as well as breast boundary overlap and Jacobian determinant of the deformation field. The statistical analysis of the results showed that symmetric diffeomorphic Demons registration method outperforms also with the best breast alignment and non-negative Jacobian values which guarantee image similarity and anatomical consistency of the transformation, due to homologous forces enforcing the pixel geometric disparities to be shortened on all the frames. We propose Demons registration as an effective technique for time-series dynamic infrared registration, to stabilize the local temperature oscillation. The aim of the second implemented CAD application is to assess contribution of calcification in plaque vulnerability and wall rupture and to find its maximum resistance before break in image-based models of carotid artery stenting. The role of calcification inside fibroatheroma during carotid artery stenting operation is controversial in which cardiologists face two major problems during the placement: (i) “plaque protrusion” (i.e. elastic fibrous caps containing early calcifications that penetrate inside the stent); (ii) “plaque vulnerability” (i.e. stiff plaques with advanced calcifications that break the arterial wall or stent). Finite Element Analysis was used to simulate the balloon and stent expansion as a preoperative patient-specific virtual framework. A nonlinear static structural analysis was performed on 20 patients acquired using in vivo MDCT angiography. The Agatston Calcium score was obtained for each patient and subject-specific local Elastic Modulus (EM) was calculated. The in silico results showed that by imposing average ultimate external load of 1.1MPa and 2.3MPa on balloon and stent respectively, average ultimate stress of 55.7±41.2kPa and 171±41.2kPa are obtained on calcifications. The study reveals that a significant positive correlation (R=0.85, p<0.0001) exists on stent expansion between EM of calcification and ultimate stress as well as Plaque Wall Stress (PWS) (R=0.92, p<0.0001), comparing to Ca score that showed insignificant associations with ultimate stress (R=0.44, p=0.057) and PWS (R=0.38, p=0.103), suggesting minor impact of Ca score in plaque rupture. These average data are in good agreement with results obtained by other research groups and we believe this approach enriches the arsenal of tools available for pre-operative prediction of carotid artery stenting procedure in the presence of calcified plaques
    corecore