8,569 research outputs found
Recommended from our members
A novel design process of low cost 3D printed ambidextrous finger designed for an ambidextrous robotic hand
This paper presents the novel mechanical design of an ambidextrous finger specifically designed for an ambidextrous anthropomorphic robotic hand actuated by pneumatic artificial muscles. The ambidextrous nature of design allows fingers to perform both left and right hand movements. The aim of our design is to reduce the number of actuators, increase the range of movements with best possible range ideally greater than a common human finger. Four prototypes are discussed in this paper; first prototype is focused on the choice of material and to consider the possible ways to reduce friction. Second prototype is designed to investigate the tendons routing configurations. Aim of third and fourth prototype is to improve the overall performance and to maximize the grasping force. Finally, a unified design (Final design) is presented in great detail. Comparison of all prototypes is done from different angles to evaluate the best design. The kinematic features of intermediate mode have been analysed to optimize both the flexibility and the robustness of the system, as well as to minimize the number of pneumatic muscles. The final design of an ambidextrous finger has developed, tested and 3D printed
Human-centered Electric Prosthetic (HELP) Hand
Through a partnership with Indian non-profit Bhagwan Mahaveer Viklang Sahayata Samiti, we designed a functional, robust, and and low cost electrically powered prosthetic hand that communicates with unilateral, transradial, urban Indian amputees through a biointerface. The device uses compliant tendon actuation, a small linear servo, and a wearable garment outfitted with flex sensors to produce a device that, once placed inside a prosthetic glove, is anthropomorphic in both look and feel. The prosthesis was developed such that future groups can design for manufacturing and distribution in India
On systematic approaches for interpreted information transfer of inspection data from bridge models to structural analysis
In conjunction with the improved methods of monitoring damage and degradation processes, the interest in reliability assessment of reinforced concrete bridges is increasing in recent years. Automated imagebased inspections of the structural surface provide valuable data to extract quantitative information about deteriorations, such as crack patterns. However, the knowledge gain results from processing this information in a structural context, i.e. relating the damage artifacts to building components. This way, transformation to structural analysis is enabled. This approach sets two further requirements: availability of structural bridge information and a standardized storage for interoperability with subsequent analysis tools. Since the involved large datasets are only efficiently processed in an automated manner, the implementation of the complete workflow from damage and building data to structural analysis is targeted in this work. First, domain concepts are derived from the back-end tasks: structural analysis, damage modeling, and life-cycle assessment. The common interoperability format, the Industry Foundation Class (IFC), and processes in these domains are further assessed. The need for usercontrolled interpretation steps is identified and the developed prototype thus allows interaction at subsequent model stages. The latter has the advantage that interpretation steps can be individually separated into either a structural analysis or a damage information model or a combination of both. This approach to damage information processing from the perspective of structural analysis is then validated in different case studies
Inferring muscle functional roles of the ostrich pelvic limb during walking and running using computer optimization
Owing to their cursorial background, ostriches (Struthio camelus) walk and run with high metabolic economy, can reach very fast running speeds and quickly execute cutting manoeuvres. These capabilities are believed to be a result of their ability to coordinate muscles to take advantage of specialized passive limb structures. This study aimed to infer the functional roles of ostrich pelvic limb muscles during gait. Existing gait data were combined with a newly developed musculoskeletal model to generate simulations of ostrich walking and running that predict muscle excitations, force and mechanical work. Consistent with previous avian electromyography studies, predicted excitation patterns showed that individual muscles tended to be excited primarily during only stance or swing. Work and force estimates show that ostrich gaits are partially hip-driven with the bi-articular hipâknee muscles driving stance mechanics. Conversely, the knee extensors acted as brakes, absorbing energy. The digital extensors generated large amounts of both negative and positive mechanical work, with increased magnitudes during running, providing further evidence that ostriches make extensive use of tendinous elastic energy storage to improve economy. The simulations also highlight the need to carefully consider non-muscular soft tissues that may play a role in ostrich gait
ReHand - a portable assistive rehabilitation hand exoskeleton
This dissertation presents a synthesis of a novel underactuated exoskeleton (namely ReHand2) thought and designed for a task-oriented rehabilitation and/or for empower the human hand.
The first part of this dissertation shows the current context about the robotic rehabilitation with a focus on hand pathologies, which influence the hand capability. The chapter is concluded with the presentation of ReHand2.
The second chapter describes the human hand biomechanics. Starting from the definition of human hand anatomy, passing through anthropometric data, to taxonomy on hand grasps and finger constraints, both from static and dynamic point of view. In addition, some information about the hand capability are given.
The third chapter analyze the current state of the art in hand exoskeleton for rehabilitation and empower tasks. In particular, the chapter presents exoskeleton technologies, from mechanisms to sensors, passing though transmission and actuators. Finally, the current state of the art in terms of prototype and commercial products is presented.
The fourth chapter introduces the concepts of underactuation with the basic explanation and the classical notation used typically in the prosthetic field. In addition, the chapter describe also the most used differential elements in the prosthetic, follow by a statical analysis. Moreover typical transmission tree at inter-finger level as well as the intra- finger underactuation are explained .
The fifth chapter presents the prototype called ReHand summarizing the device description and explanation of the working principle. It describes also the kinetostatic analysis for both, inter- and the intra-finger modules. in the last section preliminary results obtained with the exoskeleton are shown and discussed, attention is pointed out on prototypeâs problems that have carry out at the second version of the device.
The sixth chapter describes the evolution of ReHand, describing the kinematics and dynamics behaviors. In particular, for the mathematical description is introduced the notation used in order to analyze and optimize the geometry of the entire device. The introduced model is also implemented in Matlab Simulink environment. Finally, the chapter presents the new features.
The seventh chapter describes the test bench and the methodologies used to evaluate the device statical, and dynamical performances. The chapter presents and discuss the experimental results and compare them with simulated one.
Finally in the last chapter the conclusion about the ReHand project are proposed as well as the future development. In particular, the idea to test de device in relevant environments. In addition some preliminary considerations about the thumb and the wrist are introduced, exploiting the possibility to modify the entire layout of the device, for instance changing the actuator location
Stacked Tensegrity Mechanism for Medical Application
In this article a multi-segmented planar tensegrity mechanism was presented.
This mechanism has a three-segment structure with each segment residing on top
of another. The size of the segments may decrease proportionally from base to
top, resulting in a tapered shape from base to tip like an elephant trunk. The
system was mechanically formulated as having linear springs and cables
functioning as actuators. The singularities, as well as the stability of the
parallel mechanism, were analyzed by using the principle of minimum energy.
Optimization was also done to obtain the greatest angular deflection for a
segment according to a ratio between the size of the base and the moving
platform of the robotic system. The result of this work is a family of
mechanisms that can generate the same workspace for different stability
properties
- âŠ