10,641 research outputs found

    Energy Harvesting and Management for Wireless Autonomous Sensors

    No full text
    Wireless autonomous sensors that harvest ambient energy are attractive solutions, due to their convenience and economic benefits. A number of wireless autonomous sensor platforms which consume less than 100?W under duty-cycled operation are available. Energy harvesting technology (including photovoltaics, vibration harvesters, and thermoelectrics) can be used to power autonomous sensors. A developed system is presented that uses a photovoltaic module to efficiently charge a supercapacitor, which in turn provides energy to a microcontroller-based autonomous sensing platform. The embedded software on the node is structured around a framework in which equal precedent is given to each aspect of the sensor node through the inclusion of distinct software stacks for energy management and sensor processing. This promotes structured and modular design, allowing for efficient code reuse and encourages the standardisation of interchangeable protocols

    A wireless ultrasonic NDT sensor system

    Get PDF
    Ultrasonic condition monitoring technologies have been traditionally utilized in industrial and construction environments where structural integrity is of concern. Such techniques include active systems with either single or multiple transmit-receiver combinations used to obtain defect positioning and magnitude. Active sensors are implemented in two ways; in a thickness operation mode, or as an area-mapping tool operating over longer distances. In addition, passive ultrasonic receivers can be employed to detect and record acoustic emission activity. Existing equipment requires cabling for such systems leading to expensive, complicated installations. This work describes the development and operation of a system that combines these existing ultrasonic technologies with modern wireless techniques within a miniaturized, battery-operated design. A completely wireless sensor has been designed that can independently record and analyze ultrasonic signals. Integrated into the sensor are custom ultrasonic transducers, associated analogue drive and receive electronics, and a Texas Instruments Digital Signal Processor (DSP) used to both control the system and implement the signal processing routines. BlueTooth wireless communication is used for connection to a central observation station, from where network operation can be controlled. Extending battery life is of prime importance and the device employs several strategies to do this. Low voltage transducer excitation suffers from poor signal-to-noise ratios, which can be enhanced by signal processing routines implemented on the DSP. Routines investigated include averaging, digital filtering and pulse compression

    Wearable flexible lightweight modular RFID tag with integrated energy harvester

    Get PDF
    A novel wearable radio frequency identification (RFID) tag with sensing, processing, and decision-taking capability is presented for operation in the 2.45-GHz RFID superhigh frequency (SHF) band. The tag is powered by an integrated light harvester, with a flexible battery serving as an energy buffer. The proposed active tag features excellent wearability, very high read range, enhanced functionality, flexible interfacing with diverse low-power sensors, and extended system autonomy through an innovative holistic microwave system design paradigm that takes antenna design into consideration from the very early stages. Specifically, a dedicated textile shorted circular patch antenna with monopolar radiation pattern is designed and optimized for highly efficient and stable operation within the frequency band of operation. In this process, the textile antenna's functionality is augmented by reusing its surface as an integration platform for light-energy-harvesting, sensing, processing, and transceiver hardware, without sacrificing antenna performance or the wearer's comfort. The RFID tag is validated by measuring its stand-alone and on-body characteristics in free-space conditions. Moreover, measurements in a real-world scenario demonstrate an indoor read range up to 23 m in nonline-of-sight indoor propagation conditions, enabling interrogation by a reader situated in another room. In addition, the RFID platform only consumes 168.3 mu W, when sensing and processing are performed every 60 s

    Smartphone-Based pH Sensor for Home Monitoring of Pulmonary Exacerbations in Cystic Fibrosis.

    Get PDF
    Currently, Cystic Fibrosis (CF) patients lack the ability to track their lung health at home, relying instead on doctor checkups leading to delayed treatment and lung damage. By leveraging the ubiquity of the smartphone to lower costs and increase portability, a smartphone-based peripheral pH measurement device was designed to attach directly to the headphone port to harvest power and communicate with a smartphone application. This platform was tested using prepared pH buffers and sputum samples from CF patients. The system matches within ~0.03 pH of a benchtop pH meter while fully powering itself and communicating with a Samsung Galaxy S3 smartphone paired with either a glass or Iridium Oxide (IrOx) electrode. The IrOx electrodes were found to have 25% higher sensitivity than the glass probes at the expense of larger drift and matrix sensitivity that can be addressed with proper calibration. The smartphone-based platform has been demonstrated as a portable replacement for laboratory pH meters, and supports both highly robust glass probes and the sensitive and miniature IrOx electrodes with calibration. This tool can enable more frequent pH sputum tracking for CF patients to help detect the onset of pulmonary exacerbation to provide timely and appropriate treatment before serious damage occurs

    Development and deployment of a microfluidic platform for water quality monitoring

    Get PDF
    There is an increasing demand for autonomous sensor devices which can provide reliable data on key water quality parameters at a higher temporal and geographical resolution than is achievable using current approaches to sampling and monitoring. Microfluidic technology, in combination with rapid and on-going developments in the area of wireless communications, has significant potential to address this demand due to a number of advantageous features which allow the development of compact, low-cost and low-powered analytical devices. Here we report on the development of a microfluidic platform for water quality monitoring. This system has been successfully applied to in-situ monitoring of phosphate in environmental and wastewater monitoring applications. We describe a number of the technical and practical issues encountered and addressed during these deployments and summarise the current status of the technology

    Universal Solar Powered Water Quality Monitoring IoT Device and Notification System

    Get PDF
    Water constituents are often event-driven so concentrations and properties vary strongly in time. Due to this, there is a high demand for devices which can get accurate and real time measurements as these changes occur. Current methods of monitoring water quality mostly involve a team of people who collect samples which are later analyzed in a laboratory. This process is time consuming, expensive and has a slow reaction time which may lead to missing out on important changes in the water parameters. This paper describes a prototype solution which is affordable and capable of producing quick and accurate results in real time. This prototype measures the water quality using various sensors which record the pH level, temperature, total dissolved solids, conductivity and changes in the level of water. These sensors are connected to the ESP32 DevKit V4 microcontroller which processes and transmits the data in real time using Wi-Fi to the thinger.io online monitoring dashboard. This dashboard also stores all the data so it can be for analyzing the trends in changes of water quality. In addition to that, this prototype utilizes solar energy harvesting allowing it to be self-sufficiently powered throughout the year.Water constituents are often event-driven so concentrations and properties vary strongly in time. Due to this, there is a high demand for devices which can get accurate and real time measurements as these changes occur. Current methods of monitoring water quality mostly involve a team of people who collect samples which are later analyzed in a laboratory. This process is time consuming, expensive and has a slow reaction time which may lead to missing out on important changes in the water parameters. This paper describes a prototype solution which is affordable and capable of producing quick and accurate results in real time. This prototype measures the water quality using various sensors which record the pH level, temperature, total dissolved solids, conductivity and changes in the level of water. These sensors are connected to the ESP32 DevKit V4 microcontroller which processes and transmits the data in real time using Wi-Fi to the thinger.io online monitoring dashboard. This dashboard also stores all the data so it can be for analyzing the trends in changes of water quality. In addition to that, this prototype utilizes solar energy harvesting allowing it to be self-sufficiently powered throughout the year

    Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments

    Get PDF
    n this paper, we present a radiotelemetry sensor, designed as a lab-in-a-pill, which incorporates a two-channel microfabricated sensor platform for real-time measurements of temperature and pH. These two parameters have potential application for use in remote biological sensing (for example they may be used as markers that reflect the physiological environment or as indicators for disease, within the gastrointestinal tract). We have investigated the effects of biofouling on these sensors, by exploring their response time and sensitivity in a model in vitro gastrointestinal system. The artificial gastric and intestinal solutions used represent a model both for fasting, as well as for the ingestion of food and subsequent digestion to gastrointestinal chyme. The results showed a decrease in pH sensitivity after exposure of the sensors for 3 h. The response time also increased from an initial measurement time of 10 s in pure GI juice, to ca. 25 s following the ingestion of food and 80 s in simulated chyme. These in vitro results indicate that changes in viscosity in our model gastrointestinal system had a pronounced effect on the unmodified sensor
    corecore