6,224 research outputs found

    Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates

    Get PDF
    The study of cerebral anatomy in developing neonates is of great importance for the understanding of brain development during the early period of life. This dissertation therefore focuses on three challenges in the modelling of cerebral anatomy in neonates during brain development. The methods that have been developed all use Magnetic Resonance Images (MRI) as source data. To facilitate study of vascular development in the neonatal period, a set of image analysis algorithms are developed to automatically extract and model cerebral vessel trees. The whole process consists of cerebral vessel tracking from automatically placed seed points, vessel tree generation, and vasculature registration and matching. These algorithms have been tested on clinical Time-of- Flight (TOF) MR angiographic datasets. To facilitate study of the neonatal cortex a complete cerebral cortex segmentation and reconstruction pipeline has been developed. Segmentation of the neonatal cortex is not effectively done by existing algorithms designed for the adult brain because the contrast between grey and white matter is reversed. This causes pixels containing tissue mixtures to be incorrectly labelled by conventional methods. The neonatal cortical segmentation method that has been developed is based on a novel expectation-maximization (EM) method with explicit correction for mislabelled partial volume voxels. Based on the resulting cortical segmentation, an implicit surface evolution technique is adopted for the reconstruction of the cortex in neonates. The performance of the method is investigated by performing a detailed landmark study. To facilitate study of cortical development, a cortical surface registration algorithm for aligning the cortical surface is developed. The method first inflates extracted cortical surfaces and then performs a non-rigid surface registration using free-form deformations (FFDs) to remove residual alignment. Validation experiments using data labelled by an expert observer demonstrate that the method can capture local changes and follow the growth of specific sulcus

    Reduced and coded sensing methods for x-ray based security

    Full text link
    Current x-ray technologies provide security personnel with non-invasive sub-surface imaging and contraband detection in various portal screening applications such as checked and carry-on baggage as well as cargo. Computed tomography (CT) scanners generate detailed 3D imagery in checked bags; however, these scanners often require significant power, cost, and space. These tomography machines are impractical for many applications where space and power are often limited such as checkpoint areas. Reducing the amount of data acquired would help reduce the physical demands of these systems. Unfortunately this leads to the formation of artifacts in various applications, thus presenting significant challenges in reconstruction and classification. As a result, the goal is to maintain a certain level of image quality but reduce the amount of data gathered. For the security domain this would allow for faster and cheaper screening in existing systems or allow for previously infeasible screening options due to other operational constraints. While our focus is predominantly on security applications, many of the techniques can be extended to other fields such as the medical domain where a reduction of dose can allow for safer and more frequent examinations. This dissertation aims to advance data reduction algorithms for security motivated x-ray imaging in three main areas: (i) development of a sensing aware dimensionality reduction framework, (ii) creation of linear motion tomographic method of object scanning and associated reconstruction algorithms for carry-on baggage screening, and (iii) the application of coded aperture techniques to improve and extend imaging performance of nuclear resonance fluorescence in cargo screening. The sensing aware dimensionality reduction framework extends existing dimensionality reduction methods to include knowledge of an underlying sensing mechanism of a latent variable. This method provides an improved classification rate over classical methods on both a synthetic case and a popular face classification dataset. The linear tomographic method is based on non-rotational scanning of baggage moved by a conveyor belt, and can thus be simpler, smaller, and more reliable than existing rotational tomography systems at the expense of more challenging image formation problems that require special model-based methods. The reconstructions for this approach are comparable to existing tomographic systems. Finally our coded aperture extension of existing nuclear resonance fluorescence cargo scanning provides improved observation signal-to-noise ratios. We analyze, discuss, and demonstrate the strengths and challenges of using coded aperture techniques in this application and provide guidance on regimes where these methods can yield gains over conventional methods

    Magnetic resonance imaging for evaluation and optimization of photodynamic therapy

    Get PDF

    Fast and Sequence-Adaptive Whole-Brain Segmentation Using Parametric Bayesian Modeling

    Get PDF
    AbstractQuantitative analysis of magnetic resonance imaging (MRI) scans of the brain requires accurate automated segmentation of anatomical structures. A desirable feature for such segmentation methods is to be robust against changes in acquisition platform and imaging protocol. In this paper we validate the performance of a segmentation algorithm designed to meet these requirements, building upon generative parametric models previously used in tissue classification. The method is tested on four different datasets acquired with different scanners, field strengths and pulse sequences, demonstrating comparable accuracy to state-of-the-art methods on T1-weighted scans while being one to two orders of magnitude faster. The proposed algorithm is also shown to be robust against small training datasets, and readily handles images with different MRI contrast as well as multi-contrast data

    Compressed Sensing And Joint Acquisition Techniques In Mri

    Get PDF
    The relatively long scan times in Magnetic Resonance Imaging (MRI) limits some clinical applications and the ability to collect more information in a reasonable period of time. Practically, 3D imaging requires longer acquisitions which can lead to a reduction in image quality due to motion artifacts, patient discomfort, increased costs to the healthcare system and loss of profit to the imaging center. The emphasis in reducing scan time has been to a large degree through using limited k-space data acquisition and special reconstruction techniques. Among these approaches are data extrapolation methods such as constrained reconstruction techniques, data interpolation methods such as parallel imaging, and more recently another technique known as Compressed Sensing (CS). In order to recover the image components from far fewer measurements, CS exploits the compressible nature of MR images by imposing randomness in k-space undersampling schemes. In this work, we explore some intuitive examples of CS reconstruction leading to a primitive algorithm for CS MR imaging. Then, we demonstrate the application of this algorithm to MR angiography (MRA) with the goal of reducing the scan time. Our results showed reconstructions with comparable results to the fully sampled MRA images, providing up to three times faster image acquisition via CS. The CS performance in recovery of the vessels in MRA, showed slightly shrinkage of both the width of and amplitude of the vessels in 20% undersampling scheme. The spatial location of the vessels however remained intact during CS reconstruction. Another direction we pursue is the introduction of joint acquisition for accelerated multi data point MR imaging such as multi echo or dynamic imaging. Keyhole imaging and view sharing are two techniques for accelerating dynamic acquisitions, where some k-space data is shared between neighboring acquisitions. In this work, we combine the concept of CS random sampling with keyhole imaging and view sharing techniques, in order to improve the performance of each method by itself and reduce the scan time. Finally, we demonstrate the application of this new method in multi-echo spin echo (MSE) T2 mapping and compare the results with conventional methods. Our proposed technique can potentially provide up to 2.7 times faster image acquisition. The percentage difference error maps created from T2 maps generated from images with joint acquisition and fully sampled images, have a histogram with a 5-95 percentile of less than 5% error. This technique can potentially be applied to other dynamic imaging acquisitions such as multi flip angle T1 mapping or time resolved contrast enhanced MRA

    Zero-DeepSub: Zero-Shot Deep Subspace Reconstruction for Rapid Multiparametric Quantitative MRI Using 3D-QALAS

    Full text link
    Purpose: To develop and evaluate methods for 1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and 2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. Methods: A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy of the T1 and T2 maps estimated using the proposed methods was evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to 9-fold. Results: Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to 9-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. Conclusion: The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.Comment: 17 figures, 3 table
    • …
    corecore