Retrieval and Registration of Long-Range Overlapping Frames for Scalable Mosaicking of In Vivo Fetoscopy
Purpose: The standard clinical treatment of Twin-to-Twin Transfusion Syndrome
consists in the photo-coagulation of undesired anastomoses located on the
placenta which are responsible to a blood transfer between the two twins. While
being the standard of care procedure, fetoscopy suffers from a limited
field-of-view of the placenta resulting in missed anastomoses. To facilitate
the task of the clinician, building a global map of the placenta providing a
larger overview of the vascular network is highly desired. Methods: To overcome
the challenging visual conditions inherent to in vivo sequences (low contrast,
obstructions or presence of artifacts, among others), we propose the following
contributions: (i) robust pairwise registration is achieved by aligning the
orientation of the image gradients, and (ii) difficulties regarding long-range
consistency (e.g. due to the presence of outliers) is tackled via a bag-of-word
strategy, which identifies overlapping frames of the sequence to be registered
regardless of their respective location in time. Results: In addition to visual
difficulties, in vivo sequences are characterised by the intrinsic absence of
gold standard. We present mosaics motivating qualitatively our methodological
choices and demonstrating their promising aspect. We also demonstrate
semi-quantitatively, via visual inspection of registration results, the
efficacy of our registration approach in comparison to two standard baselines.
Conclusion: This paper proposes the first approach for the construction of
mosaics of placenta in in vivo fetoscopy sequences. Robustness to visual
challenges during registration and long-range temporal consistency are
proposed, offering first positive results on in vivo data for which standard
mosaicking techniques are not applicable.Comment: Accepted for publication in International Journal of Computer
Assisted Radiology and Surgery (IJCARS
Saliency-guided integration of multiple scans
we present a novel method..
Analysis of ICP variants for the registration of partially overlapping time-of-flight range images
The iterative closest point (ICP) algorithm is one of the most commonly used methods for registering partially overlapping range images. Nevertheless, this algorithm was not originally designed for this task, and many variants have been proposed in an effort to improve its prociency. The relatively new full-field amplitude-modulated time-of-flight range imaging cameras present further complications to registration in the form of measurement errors due to mixed and scattered light. This paper investigates the effectiveness of the most common ICP variants applied to range image data acquired from full-field range imaging cameras. The original ICP algorithm combined with boundary rejection performed the same as or better than the majority of variants tested. In fact, many of these variants proved to decrease the registration alignment
An evaluation method for multiview surface reconstruction algorithms
We propose a new method...
Robust and Fast 3D Scan Alignment using Mutual Information
This paper presents a mutual information (MI) based algorithm for the
estimation of full 6-degree-of-freedom (DOF) rigid body transformation between
two overlapping point clouds. We first divide the scene into a 3D voxel grid
and define simple to compute features for each voxel in the scan. The two scans
that need to be aligned are considered as a collection of these features and
the MI between these voxelized features is maximized to obtain the correct
alignment of scans. We have implemented our method with various simple point
cloud features (such as number of points in voxel, variance of z-height in
voxel) and compared the performance of the proposed method with existing
point-to-point and point-to- distribution registration methods. We show that
our approach has an efficient and fast parallel implementation on GPU, and
evaluate the robustness and speed of the proposed algorithm on two real-world
datasets which have variety of dynamic scenes from different environments
2D Reconstruction of Small Intestine's Interior Wall
Examining and interpreting of a large number of wireless endoscopic images
from the gastrointestinal tract is a tiresome task for physicians. A practical
solution is to automatically construct a two dimensional representation of the
gastrointestinal tract for easy inspection. However, little has been done on
wireless endoscopic image stitching, let alone systematic investigation. The
proposed new wireless endoscopic image stitching method consists of two main
steps to improve the accuracy and efficiency of image registration. First, the
keypoints are extracted by Principle Component Analysis and Scale Invariant
Feature Transform (PCA-SIFT) algorithm and refined with Maximum Likelihood
Estimation SAmple Consensus (MLESAC) outlier removal to find the most reliable
keypoints. Second, the optimal transformation parameters obtained from first
step are fed to the Normalised Mutual Information (NMI) algorithm as an initial
solution. With modified Marquardt-Levenberg search strategy in a multiscale
framework, the NMI can find the optimal transformation parameters in the
shortest time. The proposed methodology has been tested on two different
datasets - one with real wireless endoscopic images and another with images
obtained from Micro-Ball (a new wireless cubic endoscopy system with six image
sensors). The results have demonstrated the accuracy and robustness of the
proposed methodology both visually and quantitatively.Comment: Journal draf
- …