5,304 research outputs found

    An automated carotid pulse assessment approach using Doppler ultrasound

    Get PDF
    During cardiac arrest emergencies, lay rescuers are required to manually check the patient's carotid pulse after the delivery of defibrillation shocks to assess the cardiac resuscitation progress of the patient. As a more automated way of monitoring the resuscitation progress, a new Doppler-ultrasound-based carotid pulse assessment approach is presented in this paper. The method works by analyzing the temporal aperiodicity of Doppler shifts seen in the ultrasound echoes returned from the patient's carotid arteries. As a quantitative investigation with this method, we derived a new measure called the pulselessness indicator to assess whether a carotid pulse is absent based on the given Doppler information. To study the performance of the new carotid pulse checking method, we built a multi-channel CW Doppler prototype device to acquire Doppler data in vivo during cardiac arrest experiments conducted on five different swines and computed pulselessness indicator estimates with these data. Our results indicated that the Doppler-based pulse checking approach has good sensitivity and specificity: it had a pulselessness detection rate greater than 0.9 for a given false alarm rate of 0.05. As a further analysis, the prototype device was applied to other experiments where the swine had suffered cardiac arrest for over five minutes. It showed a consistent assessment performance on the monitoring of the swine's resuscitation progress after defibrillation and chest compressions. © 2006 IEEE.published_or_final_versio

    In-Suit Doppler Technology Assessment

    Get PDF
    The objective of this program was to perform a technology assessment survey of non-invasive air embolism detection utilizing Doppler ultrasound methodologies. The primary application of this technology will be a continuous monitor for astronauts while performing extravehicular activities (EVA's). The technology assessment was to include: (1) development of a full understanding of all relevant background research; and (2) a survey of the medical ultrasound marketplace for expertise, information, and technical capability relevant to this development. Upon completion of the assessment, LSR was to provide an overview of technological approaches and R&D/manufacturing organizations

    The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action

    Get PDF
    Arteriosclerosis; Ultrasound; Vascular ageingArteriosclerosi; Ecografia; Envelliment vascularArteriosclerosis; Ecografía; Envejecimiento vascularNon-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.This article is based upon work from COST Action CA18216 VascAgeNet, supported by COST (European Cooperation in Science and Technology, www.cost.eu). A.G. has received funding from “La Caixa” Foundation (LCF/BQ/PR22/11920008). R.E.C is supported by the National Health and Medical Research Council of Australia (reference: 2009005) and by a National Heart Foundation Future Leader Fellowship (reference: 105636). J.A. acknowledges support from the British Heart Foundation [PG/15/104/31913], the Wellcome EPSRC Centre for Medical Engineering at King's College London [WT 203148/Z/16/Z], and the Cardiovascular MedTech Co-operative at Guy's and St Thomas' NHS Foundation Trust [MIC-2016-019]

    Carotid artery contrast enhanced ultrasound

    Get PDF

    Carotid artery contrast enhanced ultrasound

    Get PDF

    A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology

    Get PDF
    The endothelium is the innermost lining of the vasculature and is involved in the maintenance of vascular homeostasis. Damage to the endothelium may predispose the vessel to atherosclerosis and increase the risk for cardiovascular disease. Assessments of peripheral endothelial function are good indicators of early abnormalities in the vascular wall and correlate well with assessments of coronary endothelial function. The present manuscript details the important methodological steps necessary for the assessment of microvascular endothelial function using laser Doppler imaging with iontophoresis, large vessel endothelial function using flow-mediated dilatation, and carotid atherosclerosis using carotid artery ultrasound. A discussion on the methodological considerations for each of the techniques is also presented, and recommendations are made for future research

    Automatic Ultrasound Scanning

    Get PDF
    • …
    corecore