2,839 research outputs found

    CT Image Reconstruction by Spatial-Radon Domain Data-Driven Tight Frame Regularization

    Full text link
    This paper proposes a spatial-Radon domain CT image reconstruction model based on data-driven tight frames (SRD-DDTF). The proposed SRD-DDTF model combines the idea of joint image and Radon domain inpainting model of \cite{Dong2013X} and that of the data-driven tight frames for image denoising \cite{cai2014data}. It is different from existing models in that both CT image and its corresponding high quality projection image are reconstructed simultaneously using sparsity priors by tight frames that are adaptively learned from the data to provide optimal sparse approximations. An alternative minimization algorithm is designed to solve the proposed model which is nonsmooth and nonconvex. Convergence analysis of the algorithm is provided. Numerical experiments showed that the SRD-DDTF model is superior to the model by \cite{Dong2013X} especially in recovering some subtle structures in the images

    GPU-based Iterative Cone Beam CT Reconstruction Using Tight Frame Regularization

    Full text link
    X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images from undersampled and noisy projection data so as to lower the imaging dose. For this purpose, we have developed an iterative tight frame (TF) based CBCT reconstruction algorithm. A condition that a real CBCT image has a sparse representation under a TF basis is imposed in the iteration process as regularization to the solution. To speed up the computation, a multi-grid method is employed. Our GPU implementation has achieved high computational efficiency and a CBCT image of resolution 512\times512\times70 can be reconstructed in ~5 min. We have tested our algorithm on a digital NCAT phantom and a physical Catphan phantom. It is found that our TF-based algorithm is able to reconstrct CBCT in the context of undersampling and low mAs levels. We have also quantitatively analyzed the reconstructed CBCT image quality in terms of modulation-transfer-function and contrast-to-noise ratio under various scanning conditions. The results confirm the high CBCT image quality obtained from our TF algorithm. Moreover, our algorithm has also been validated in a real clinical context using a head-and-neck patient case. Comparisons of the developed TF algorithm and the current state-of-the-art TV algorithm have also been made in various cases studied in terms of reconstructed image quality and computation efficiency.Comment: 24 pages, 8 figures, accepted by Phys. Med. Bio

    Multi-GPU Acceleration of Iterative X-ray CT Image Reconstruction

    Get PDF
    X-ray computed tomography is a widely used medical imaging modality for screening and diagnosing diseases and for image-guided radiation therapy treatment planning. Statistical iterative reconstruction (SIR) algorithms have the potential to significantly reduce image artifacts by minimizing a cost function that models the physics and statistics of the data acquisition process in X-ray CT. SIR algorithms have superior performance compared to traditional analytical reconstructions for a wide range of applications including nonstandard geometries arising from irregular sampling, limited angular range, missing data, and low-dose CT. The main hurdle for the widespread adoption of SIR algorithms in multislice X-ray CT reconstruction problems is their slow convergence rate and associated computational time. We seek to design and develop fast parallel SIR algorithms for clinical X-ray CT scanners. Each of the following approaches is implemented on real clinical helical CT data acquired from a Siemens Sensation 16 scanner and compared to the straightforward implementation of the Alternating Minimization (AM) algorithm of O’Sullivan and Benac [1]. We parallelize the computationally expensive projection and backprojection operations by exploiting the massively parallel hardware architecture of 3 NVIDIA TITAN X Graphical Processing Unit (GPU) devices with CUDA programming tools and achieve an average speedup of 72X over a straightforward CPU implementation. We implement a multi-GPU based voxel-driven multislice analytical reconstruction algorithm called Feldkamp-Davis-Kress (FDK) [2] and achieve an average overall speedup of 1382X over the baseline CPU implementation by using 3 TITAN X GPUs. Moreover, we propose a novel adaptive surrogate-function based optimization scheme for the AM algorithm, resulting in more aggressive update steps in every iteration. On average, we double the convergence rate of our baseline AM algorithm and also improve image quality by using the adaptive surrogate function. We extend the multi-GPU and adaptive surrogate-function based acceleration techniques to dual-energy reconstruction problems as well. Furthermore, we design and develop a GPU-based deep Convolutional Neural Network (CNN) to denoise simulated low-dose X-ray CT images. Our experiments show significant improvements in the image quality with our proposed deep CNN-based algorithm against some widely used denoising techniques including Block Matching 3-D (BM3D) and Weighted Nuclear Norm Minimization (WNNM). Overall, we have developed novel fast, parallel, computationally efficient methods to perform multislice statistical reconstruction and image-based denoising on clinically-sized datasets

    Research Status and Prospect for CT Imaging

    Get PDF
    Computed tomography (CT) is a very valuable imaging method and plays an important role in clinical diagnosis. As people pay more and more attention to radiation doses these years, decreasing CT radiation dose without affecting image quality is a hot direction for research of medical imaging in recent years. This chapter introduces the research status of low-dose technology from following aspects: low-dose scan implementation, reconstruction methods and image processing methods. Furthermore, other technologies related to the development tendency of CT, such as automatic tube current modulation technology, rapid peak kilovoltage (kVp) switching technology, dual-source CT technology and Nano-CT, are also summarized. Finally, the future research prospect are discussed and analyzed
    • …
    corecore