    A Review of Fault Diagnosing Methods in Power Transmission Systems

    Get PDF
    Transient stability is important in power systems. Disturbances like faults need to be segregated to restore transient stability. A comprehensive review of fault diagnosing methods in the power transmission system is presented in this paper. Typically, voltage and current samples are deployed for analysis. Three tasks/topics; fault detection, classification, and location are presented separately to convey a more logical and comprehensive understanding of the concepts. Feature extractions, transformations with dimensionality reduction methods are discussed. Fault classification and location techniques largely use artificial intelligence (AI) and signal processing methods. After the discussion of overall methods and concepts, advancements and future aspects are discussed. Generalized strengths and weaknesses of different AI and machine learning-based algorithms are assessed. A comparison of different fault detection, classification, and location methods is also presented considering features, inputs, complexity, system used and results. This paper may serve as a guideline for the researchers to understand different methods and techniques in this field

    An equivalent circuit for the evaluation of cross-country fault currents in medium voltage (MV) distribution networks

    Get PDF
    A Cross-Country Fault (CCF) is the simultaneous occurrence of a couple of Line-to-Ground Faults (LGFs), affecting different phases of same feeder or of two distinct ones, at different fault locations. CCFs are not uncommon in medium voltage (MV) public distribution networks operated with ungrounded or high-impedance neutral: despite the relatively small value of LGF current that is typical of such networks, CCF currents can be comparable to those that are found in Phase-To-Phase Faults, if the affected feeder(s) consists of cables. This occurs because the faulted cables' sheaths/screens provide a continuous, relatively low-impedance metallic return path to the fault currents. An accurate evaluation is in order, since the resulting current magnitudes can overheat sheaths/screens, endangering cable joints and other plastic sheaths. Such evaluation, however, requires the modeling of the whole MV network in the phase domain, simulating cable screens and their connections to the primary and secondary substation earth electrodes by suitable computer programs, such as ATP (which is the acronym for alternative transient program) or EMTP (the acronym for electromagnetic transient program), with substantial input data being involved. This paper presents a simplified yet accurate circuit model of the faulted MV network, taking into account the CCF currents' return path (cable sheaths/screens, ground conductors, and earthing resistances of secondary substations). The proposed CCF model can be implemented in a general-purpose simulation program, and it yields accurate fault currents estimates: for a 20 kV network case study, the comparison with accurate ATP simulations evidences mismatches mostly smaller than 2%, and never exceeding 5%

    Intercircuit faults and distance relaying of dual-circuit lines

    Full text link
    The main sources of error and other difficulties associated with the distance protection of dual-circuit transmission lines are well known. However, the design or selection of protection schemes usually fails to consider some of the more extraordinary faults that do occur. This pape r considers the observed impedances that result from intercircuit faults on a simulated dual-circuit transmission line, where variations in the phasing as well as the impedance ratios have been considered. The simulations performed with the Alternative Transients Program show that intercircuit faults may be undetectable in the instantaneous protection zone depending on the scheme adopted and the impedances of the surrounding network. The observed under-reaching has the potential to lead to a loss of major loads, maloperation of single-pole tripping schemes and even system instabilities based on the critical clearance requirements. © 2005 IEEE

    NEW ACCURATE FAULT LOCATION ALGORITHM FOR PARALLEL TRANSMISSION LINES

    Get PDF
    Electric power systems have been in existence for over a century. Electric power transmission line systems play an important role in carrying electrical power to customers everywhere. The number of transmission lines in power systems is increasing as global demand for power has increased. Parallel transmission lines are widely used in the modern transmission system for higher reliability. The parallel lines method has economic and environmental advantages over single circuit. A fault that occurs on a power transmission line will cause long outage time if the fault location is not located as quickly as possible. The faster the fault location is found, the sooner the system can be restored and outage time can be reduced. The main focus of this research is to develop a new accurate fault location algorithm for parallel transmission lines to identify the fault location for long double-circuit transmission lines, taking into consideration mutual coupling impedance, mutual coupling admittance, and shunt capacitance of the line. In this research, the equivalent PI circuit based on a distributed parameter line model for positive, negative, and zero sequence networks have been constructed for system analysis during the fault. The new method uses only the voltage and current from one end of parallel lines to calculate the fault distance. This research approaches the problem by derivation all equations from positive sequence, negative sequence, and zero sequence network by using KVL and KCL. Then, the fault location is obtained by solving these equations. EMTP has been utilized to generate fault cases under various fault conditions with different fault locations, fault types and fault resistances. Then the algorithm is evaluated using the simulated data. The results have shown that the developed algorithm can achieve highly accurate estimates and is promising for practical applications

    Protection of Future Electricity Systems

    Get PDF
    The electrical energy industry is undergoing dramatic changes: massive deployment of renewables, increasing share of DC networks at transmission and distribution levels, and at the same time, a continuing reduction in conventional synchronous generation, all contribute to a situation where a variety of technical and economic challenges emerge. As the society’s reliance on electrical power continues to increase as a result of international decarbonisation commitments, the need for secure and uninterrupted delivery of electrical energy to all customers has never been greater. Power system protection plays an important enabling role in future decarbonized energy systems. This book includes ten papers covering a wide range of topics related to protection system problems and solutions, such as adaptive protection, protection of HVDC and LVDC systems, unconventional or enhanced protection methods, protection of superconducting transmission cables, and high voltage lightning protection. This volume has been edited by Adam Dyśko, Senior Lecturer at the University of Strathclyde, UK, and Dimitrios Tzelepis, Research Fellow at the University of Strathclyde

    Simulation of Distance Relay Operation on Fault Condition in MATLAB Software/Simulink

    Get PDF
    In this paper a distance relay is simulated in theproposed transmission line protection which is combinationof overhead line and significant part of underground cable.Transmission line is modeled as distributed parameter insteadof lumped parameter to have more accurate analysis compareto conventional analysis. Voltage and current are sampled atrelay point. But, high charging current of cable affects distancerelay operation. Using appropriate filtering can reduce chargingcurrent effect on distance relay. Simulated impedance will becompared with positive sequence impedance of power system inorder to evaluate simulated relay. The relay shows a good resultfor faults in zone 1, but high resistance faults force distance relayto mis-operation

    Design and implementation of ANN based phase comparators applied to transmission line protection

    Get PDF
    There has been significant development in the area of neural network based power system protection in the previous decade. Neural network technology has been applied for various protective relaying functions including distance protection. The reliability and efficiency of ANN based distance relays is improving with the developing digital technologies. There are, however, some inherent deficiencies that still exist in the way these relays are designed. This research addresses some of these issues and proposes an improved protective relaying scheme. The traditional ANN distance relay designs use parameter estimation algorithms to determine the phasors of currents and voltages. These phasors are used as inputs to determine the distance of a fault from relay location. The relays are trained and tested on this criterion; however, no specific relay characteristic has been defined. There is a need for development of a new methodology that will enable designing of an ANN that works as a generic distance relay with clearly defined operating boundary. This research work presents a modified distance relaying algorithm that has been combined with a neural network approach to eliminate the use of phasors. The neural network is trained to recognize faults on basis of a specific relay characteristic. The algorithm is flexible and has been extended for the design of other relays. The neural network has been trained using pure sinusoidal values and has been tested on a 17-bus power system simulated in PSCAD. The training and testing of the neural network on different systems ensures that the relay is generic in nature. The proposed relay can be used on any transmission line without re-training the neural network. The design has been tested for different fault conditions including different fault resistances and fault inception angles. The test results show that the relay is able to detect faults in lesser time as compared to conventional relay algorithms while maintaining the integrity of relay boundaries

    The power system and microgrid protection-a review

    Get PDF
    In recent years, power grid infrastructures have been changing from a centralized power generation model to a paradigm where the generation capability is spread over an increasing number of small power stations relying on renewable energy sources. A microgrid is a local network including renewable and non-renewable energy sources as well as distributed loads. Microgrids can be operated in both grid-connected and islanded modes to fill the gap between the significant increase in demand and storage of electricity and transmission issues. Power electronics play an important role in microgrids due to the penetration of renewable energy sources. While microgrids have many benefits for power systems, they cause many challenges, especially in protection systems. This paper presents a comprehensive review of protection systems with the penetration of microgrids in the distribution network. The expansion of a microgrid affects the coordination and protection by a change in the current direction in the distribution network. Various solutions have been suggested in the literature to resolve the microgrid protection issues. The conventional coordination of the protection system is based on the time delays between relays as the primary and backup protection. The system protection scheme has to be changed in the presence of a microgrid, so several protection schemes have been proposed to improve the protection system. Microgrids are classified into different types based on the DC/AC system, communication infrastructure, rotating synchronous machine or inverter-based distributed generation (DG), etc. Finally, we discuss the trend of future protection schemes and compare the conventional power systems

    Fault Location Effect on Short-Circuit Calculations of a TCVR Compensated Line in Algeria

    Get PDF
    This research work investigated the effect of fault location on short-circuit calculations for a high voltage transmission line equipped with a novel FACTS device, namely Thyristor Controlled Voltage Regulator (TCVR). This main function of this device was to control the voltage and active power of the line. The paper considered a study case for a 220 kV transmission line, in the Algerian transmission power network, which was subjected to a phase to earth fault in the presence of a fixed fault resistance. The paper presented theoretical analysis of the short-circuit calculations which was confirmed by the illustrated simulation results. Simulation results showed the impact of the fault location on the symmetrical current and voltage components of the line, and transmission line phase currents and voltages; before using TCVR and in the presence of TCVR for both cases of positive and negative TCVR controlled voltage
    • …