372 research outputs found

    An Energy-Efficient, Dynamic Voltage Scaling Neural Stimulator for a Proprioceptive Prosthesis

    Get PDF
    Accepted versio

    Advances in Microelectronics for Implantable Medical Devices

    Get PDF
    Implantable medical devices provide therapy to treat numerous health conditions as well as monitoring and diagnosis. Over the years, the development of these devices has seen remarkable progress thanks to tremendous advances in microelectronics, electrode technology, packaging and signal processing techniques. Many of today’s implantable devices use wireless technology to supply power and provide communication. There are many challenges when creating an implantable device. Issues such as reliable and fast bidirectional data communication, efficient power delivery to the implantable circuits, low noise and low power for the recording part of the system, and delivery of safe stimulation to avoid tissue and electrode damage are some of the challenges faced by the microelectronics circuit designer. This paper provides a review of advances in microelectronics over the last decade or so for implantable medical devices and systems. The focus is on neural recording and stimulation circuits suitable for fabrication in modern silicon process technologies and biotelemetry methods for power and data transfer, with particular emphasis on methods employing radio frequency inductive coupling. The paper concludes by highlighting some of the issues that will drive future research in the field

    A Versatile Hermetically Sealed Microelectronic Implant for Peripheral Nerve Stimulation Applications

    Get PDF
    This article presents a versatile neurostimulation platform featuring a fully implantable multi-channel neural stimulator for chronic experimental studies with freely moving large animal models involving peripheral nerves. The implant is hermetically sealed in a ceramic enclosure and encapsulated in medical grade silicone rubber, and then underwent active tests at accelerated aging conditions at 100°C for 15 consecutive days. The stimulator microelectronics are implemented in a 0.6-μm CMOS technology, with a crosstalk reduction scheme to minimize cross-channel interference, and high-speed power and data telemetry for battery-less operation. A wearable transmitter equipped with a Bluetooth Low Energy radio link, and a custom graphical user interface provide real-time, remotely controlled stimulation. Three parallel stimulators provide independent stimulation on three channels, where each stimulator supports six stimulating sites and two return sites through multiplexing, hence the implant can facilitate stimulation at up to 36 different electrode pairs. The design of the electronics, method of hermetic packaging and electrical performance as well as in vitro testing with electrodes in saline are presented

    A Multichannel High-Frequency Power-Isolated Neural Stimulator With Crosstalk Reduction

    Get PDF
    In neuroprostheses applications requiring simultaneous stimulations on a multielectrode array, electric crosstalk, the spatial interaction between electric fields from various electrodes is a major limitation to the performance of multichannel stimulation. This paper presents a multichannel stimulator design that combines high-frequency current stimulation (using biphasic charge-balanced chopped pulse profile) with a switched-capacitor power isolation method. The approach minimizes crosstalk and is particularly suitable for fully integrated realization. A stimulator fabricated in a 0.6 & #x03BC;m CMOS high-voltage technology is presented. It is used to implement a multichannel, high-frequency, power-isolated stimulator. Crosstalk reduction is demonstrated with electrodes in physiological media while the efficacy of the high-frequency stimulator chip is proven in vivo. The stimulator provides fully independent operation on multiple channels and full flexibility in the design of neural modulation protocols

    Advances in Scalable Implantable Systems for Neurostimulation Using Networked ASICs

    Get PDF
    Neurostimulation is a known method for restoring lost functions to neurologically impaired patients. This paper describes recent advances in scalable implantable stimulation systems using networked application specific integrated circuits (ASICs). It discusses how they can meet the ever-growing demand for high-density neural interfacing and long-term reliability. A detailed design example of an implantable (inductively linked) scalable stimulation system for restoring lower limb functions in paraplegics after spinal cord injury is presented. It comprises a central hub implanted at the costal margin and multiple Active Books which provide the interface for stimulating nerve roots in the cauda equina. A 16-channel stimulation system using four Active Books is demonstrated. Each Active Book has an embedded ASIC, which is responsible for initiating stimulus current to the electrodes. It also ensures device safety by monitoring temperature, humidity, and peak electrode voltage during stimulation. The implant hub was implemented using a microcontroller-based circuit. The ASIC in the Active Book was fabricated using XFAB’s 0.6-µm high-voltage CMOS process. The stimulation system does not require an accurate reference clock in the implant. Measured results are provided

    Advances in Microelectronics for Implantable Medical Devices

    Get PDF

    Enhancing selectivity of minimally invasive peripheral nerve interfaces using combined stimulation and high frequency block: from design to application

    Get PDF
    The discovery of the excitable property of nerves was a fundamental step forward in our knowledge of the nervous system and our ability to interact with it. As the injection of charge into tissue can drive its artificial activation, devices have been conceived that can serve healthcare by substituting the input or output of the peripheral nervous system when damage or disease has rendered it inaccessible or its action pathological. Applications are far-ranging and transformational as can be attested by the success of neuroprosthetics such as the cochlear implant. However, the body’s immune response to invasive implants have prevented the use of more selective interfaces, leading to therapy side-effects and off-target activation. The inherent tradeoff between the selectivity and invasiveness of neural interfaces, and the consequences thereof, is still a defining problem for the field. More recently, continued research into how nervous tissue responds to stimulation has led to the discovery of High Frequency Alternating Current (HFAC) block as a stimulation method with inhibitory effects for nerve conduction. While leveraging the structure of the peripheral nervous system, this neuromodulation technique could be a key component in efforts to improve the selectivity-invasiveness tradeoff and provide more effective neuroprosthetic therapy while retaining the safety and reliability of minimally invasive neural interfaces. This thesis describes work investigating the use of HFAC block to improve the selectivity of peripheral nerve interfaces, towards applications such as bladder control or vagus nerve stimulation where selective peripheral nerve interfaces cannot be used, and yet there is an unmet need for more selectivity from stimulation-based therapy. An overview of the underlying neuroanatomy and electrophysiology of the peripheral nervous system combined with a review of existing electrode interfaces and electrochemistry will serve to inform the problem space. Original contributions are the design of a custom multi-channel stimulator able to combine conventional and high frequency stimulation, establishing a suitable experimental platform for ex-vivo electrophysiology of the rat sciatic nerve model for HFAC block, and exploratory experiments to determine the feasibility of using HFAC block in combination with conventional stimulation to enhance the selectivity of minimally-invasive peripheral nerve interfaces.Open Acces

    An implantable micro-system for neural prosthesis control and sensory feedback restoration in amputees

    Get PDF
    In this work, the prototype of an electronic bi-directional interface between the Peripheral Nervous System (PNS) and a neuro-controlled hand prosthesis is presented. The system is composed of two Integrated Circuits (ICs): a standard CMOS device for neural recording and a High Voltage (HV) CMOS device for neural stimulation. The integrated circuits have been realized in two different 0.35μm CMOS processes available fromAustriaMicroSystem(AMS). The recoding IC incorporates 8 channels each including the analog front-end and the A/D conversion based on a sigma delta architecture. It has a total area of 16.8mm2 and exhibits an overall power consumption of 27.2mW. The neural stimulation IC is able to provide biphasic current pulses to stimulate 8 electrodes independently. A voltage booster generates a 17V voltage supply in order to guarantee the programmed stimulation current even in case of high impedances at the electrode-tissue interface in the order of tens of k­. The stimulation patterns, generated by a 5-bit current DAC, are programmable in terms of amplitude, frequency and pulse width. Due to the huge capacitors of the implemented voltage boosters, the stimulation IC has a wider area of 18.6mm2. In addition, a maximum power consumption of 29mW was measured. Successful in-vivo experiments with rats having a TIME electrode implanted in the sciatic nerve were carried out, showing the capability of recording neural signals in the tens of microvolts, with a global noise of 7μVrms , and to selectively elicit the tibial and plantarmuscles using different active sites of the electrode. In order to get a completely implantable interface, a biocompatible and biostable package was designed. It hosts the developed ICs with the minimal electronics required for their proper operation. The package consists of an alumina tube closed at both extremities by two ceramic caps hermetically sealed on it. Moreover, the two caps serve as substrate for the hermetic feedthroughs to enable the device powering and data exchange with the external digital controller implemented on a Field-Programmable Gate Array (FPGA) board. The package has an outer diameter of 7mm and a total length of 26mm. In addition, a humidity and temperature sensor was also included inside the package to allow future hermeticity and life-time estimation tests. Moreover, a wireless, wearable and non-invasive EEG recording system is proposed in order to improve the control over the artificial limb,by integrating the neural signals recorded from the PNS with those directly acquired from the brain. To first investigate the system requirements, a Component-Off-The-Shelf (COTS) device was designed. It includes a low-power 8- channel acquisition module and a Bluetooth (BT) transceiver to transmit the acquired data to a remote platform. It was designed with the aimof creating a cheap and user-friendly system that can be easily interfaced with the nowadays widely spread smartphones or tablets by means of a mobile-based application. The presented system, validated through in-vivo experiments, allows EEG signals recording at different sample rates and with a maximum bandwidth of 524Hz. It was realized on a 19cm2 custom PCB with a maximum power consumption of 270mW
    corecore