37,932 research outputs found
Linear-Array Photoacoustic Imaging Using Minimum Variance-Based Delay Multiply and Sum Adaptive Beamforming Algorithm
In Photoacoustic imaging (PA), Delay-and-Sum (DAS) beamformer is a common
beamforming algorithm having a simple implementation. However, it results in a
poor resolution and high sidelobes. To address these challenges, a new
algorithm namely Delay-Multiply-and-Sum (DMAS) was introduced having lower
sidelobes compared to DAS. To improve the resolution of DMAS, a novel
beamformer is introduced using Minimum Variance (MV) adaptive beamforming
combined with DMAS, so-called Minimum Variance-Based DMAS (MVB-DMAS). It is
shown that expanding the DMAS equation results in multiple terms representing a
DAS algebra. It is proposed to use the MV adaptive beamformer instead of the
existing DAS. MVB-DMAS is evaluated numerically and experimentally. In
particular, at the depth of 45 mm MVB-DMAS results in about 31 dB, 18 dB and 8
dB sidelobes reduction compared to DAS, MV and DMAS, respectively. The
quantitative results of the simulations show that MVB-DMAS leads to improvement
in full-width-half-maximum about 96 %, 94 % and 45 % and signal-to-noise ratio
about 89 %, 15 % and 35 % compared to DAS, DMAS, MV, respectively. In
particular, at the depth of 33 mm of the experimental images, MVB-DMAS results
in about 20 dB sidelobes reduction in comparison with other beamformers.Comment: This is the final version of this paper, which is accepted in the
"Journal of Biomedical Optics". Compared to previous versions, this version
contains more experiments and evaluatio
Acoustical structured illumination for super-resolution ultrasound imaging.
Structured illumination microscopy is an optical method to increase the spatial resolution of wide-field fluorescence imaging beyond the diffraction limit by applying a spatially structured illumination light. Here, we extend this concept to facilitate super-resolution ultrasound imaging by manipulating the transmitted sound field to encode the high spatial frequencies into the observed image through aliasing. Post processing is applied to precisely shift the spectral components to their proper positions in k-space and effectively double the spatial resolution of the reconstructed image compared to one-way focusing. The method has broad application, including the detection of small lesions for early cancer diagnosis, improving the detection of the borders of organs and tumors, and enhancing visualization of vascular features. The method can be implemented with conventional ultrasound systems, without the need for additional components. The resulting image enhancement is demonstrated with both test objects and ex vivo rat metacarpals and phalanges
Recommended from our members
Optical Coherence Tomography – Variations on a Theme
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Optical Coherence Tomography (OCT) has developed extensively over the last 23 years. This paper reviews some of the imaging techniques based on OCT with particular reference to the trade-offs between lateral and axial resolution, working distance, imaging depth, acquisition speed (enabling real time observation and 3D imaging), imaged area/volume, contrast enhancement – including velocity measurement, and system complexity – including detectors, light sources and the optical path. The majority of applications of OCT are biomedical, especially ophthalmology, endoscopy and intravascular imaging. However, some industrial applications are emerging particularly for non-destructive testing and quality control, such as in the production of MEMS devices, or the non-destructive detection of sub-surface strain fields in injected moulded polymer parts
A Neural Model of How the Brain Computes Heading from Optic Flow in Realistic Scenes
Animals avoid obstacles and approach goals in novel cluttered environments using visual information, notably optic flow, to compute heading, or direction of travel, with respect to objects in the environment. We present a neural model of how heading is computed that describes interactions among neurons in several visual areas of the primate magnocellular pathway, from retina through V1, MT+, and MSTd. The model produces outputs which are qualitatively and quantitatively similar to human heading estimation data in response to complex natural scenes. The model estimates heading to within 1.5° in random dot or photo-realistically rendered scenes and within 3° in video streams from driving in real-world environments. Simulated rotations of less than 1 degree per second do not affect model performance, but faster simulated rotation rates deteriorate performance, as in humans. The model is part of a larger navigational system that identifies and tracks objects while navigating in cluttered environments.National Science Foundation (SBE-0354378, BCS-0235398); Office of Naval Research (N00014-01-1-0624); National-Geospatial Intelligence Agency (NMA201-01-1-2016
- …