579 research outputs found

    High precision motion control of parallel robots with imperfections and manufacturing tolerances

    Get PDF
    This work attempts to achieve precise motion control using parallel robots with manufacturing tolerances and inaccuracies by migrating the measurements from their joint space to task space in order to decrease control system’s sensitivity to any kinematical uncertainty rather than calibrating the parallel plant. The problem of dynamical model uncertainties and its effect on the derivation of the control law is also addressed in this work through disturbance estimation and compensation. Eventually, both task space measurement and disturbance estimation are combined to formulate a control framework that is unsensitive to either kinematical and dynamical system uncertainties

    Experiences with the JPL telerobot testbed: Issues and insights

    Get PDF
    The Jet Propulsion Laboratory's (JPL) Telerobot Testbed is an integrated robotic testbed used to develop, implement, and evaluate the performance of advanced concepts in autonomous, tele-autonomous, and tele-operated control of robotic manipulators. Using the Telerobot Testbed, researchers demonstrated several of the capabilities and technological advances in the control and integration of robotic systems which have been under development at JPL for several years. In particular, the Telerobot Testbed was recently employed to perform a near completely automated, end-to-end, satellite grapple and repair sequence. The task of integrating existing as well as new concepts in robot control into the Telerobot Testbed has been a very difficult and timely one. Now that researchers have completed the first major milestone (i.e., the end-to-end demonstration) it is important to reflect back upon experiences and to collect the knowledge that has been gained so that improvements can be made to the existing system. It is also believed that the experiences are of value to the others in the robotics community. Therefore, the primary objective here will be to use the Telerobot Testbed as a case study to identify real problems and technological gaps which exist in the areas of robotics and in particular systems integration. Such problems have surely hindered the development of what could be reasonably called an intelligent robot. In addition to identifying such problems, researchers briefly discuss what approaches have been taken to resolve them or, in several cases, to circumvent them until better approaches can be developed

    Caveats on the first-generation da Vinci Research Kit: latent technical constraints and essential calibrations

    Full text link
    Telesurgical robotic systems provide a well established form of assistance in the operating theater, with evidence of growing uptake in recent years. Until now, the da Vinci surgical system (Intuitive Surgical Inc, Sunnyvale, California) has been the most widely adopted robot of this kind, with more than 6,700 systems in current clinical use worldwide [1]. To accelerate research on robotic-assisted surgery, the retired first-generation da Vinci robots have been redeployed for research use as "da Vinci Research Kits" (dVRKs), which have been distributed to research institutions around the world to support both training and research in the sector. In the past ten years, a great amount of research on the dVRK has been carried out across a vast range of research topics. During this extensive and distributed process, common technical issues have been identified that are buried deep within the dVRK research and development architecture, and were found to be common among dVRK user feedback, regardless of the breadth and disparity of research directions identified. This paper gathers and analyzes the most significant of these, with a focus on the technical constraints of the first-generation dVRK, which both existing and prospective users should be aware of before embarking onto dVRK-related research. The hope is that this review will aid users in identifying and addressing common limitations of the systems promptly, thus helping to accelerate progress in the field.Comment: 15 pages, 7 figure

    Hand-eye calibration, constraints and source synchronisation for robotic-assisted minimally invasive surgery

    Get PDF
    In robotic-assisted minimally invasive surgery (RMIS), the robotic system allows surgeons to remotely control articulated instruments to perform surgical interventions and introduces a potential to implement computer-assisted interventions (CAI). However, the information in the camera must be correctly transformed into the robot coordinate as its movement is controlled by the robot kinematic. Therefore, determining the rigid transformation connecting the coordinates is necessary. Such process is called hand-eye calibration. One of the challenges in solving the hand-eye problem in the RMIS setup is data asynchronicity, which occurs when tracking equipments are integrated into a robotic system and create temporal misalignment. For the calibration itself, noise in the robot and camera motions can be propagated to the calibrated result and as a result of a limited motion range, the error cannot be fully suppressed. Finally, the calibration procedure must be adaptive and simple so a disruption in a surgical workflow is minimal since any change in the setup may require another calibration procedure. We propose solutions to deal with the asynchronicity, noise sensitivity, and a limited motion range. We also propose a potential to use a surgical instrument as the calibration target to reduce the complexity in the calibration procedure. The proposed algorithms are validated through extensive experiments with synthetic and real data from the da Vinci Research Kit and the KUKA robot arms. The calibration performance is compared with existing hand-eye algorithms and it shows promising results. Although the calibration using a surgical instrument as the calibration target still requires a further development, results indicate that the proposed methods increase the calibration performance, and contribute to finding an optimal solution to the hand-eye problem in robotic surgery
    corecore