7 research outputs found

    A novel technique for reducing false positive detections in CAD-CTC

    Get PDF
    Computed tomography colonoscopy (CTC) is an emerging alternative to conventional colonoscopy for colorectal cancer screening. A series of computer assisted diagnosis (CAD) techniques have been developed for use in CTC. Although high levels of accuracy for polyp detection have been reported, the problem of excessive false positive detections still warrants attention. We present a CAD-CTC technique that has been developed specifically to reduce the number of false positive detections without compromising polyp detection accuracy. The technique incorporates a novel intermediate stage that restructures initial polyp candidates so that they conform more closely to the shape of actual polyps. The restructuring process causes false positives to expand to include more false positive characteristics, whereas, actual polyps retain their original polyp-like characteristics. An evaluation of the documented technique demonstrated that it can be successfully applied to the majority of polyp candidates, and that its use can reduce the number of false positive detections by up to 57.8%

    A novel technique for reducing false positive detections in CAD-CTC

    Get PDF
    Computed tomography colonoscopy (CTC) is an emerging alternative to conventional colonoscopy for colorectal cancer screening. A series of computer assisted diagnosis (CAD) techniques have been developed for use in CTC. Although high levels of accuracy for polyp detection have been reported, the problem of excessive false positive detections still warrants attention. We present a CAD-CTC technique that has been developed specifically to reduce the number of false positive detections without compromising polyp detection accuracy. The technique incorporates a novel intermediate stage that restructures initial polyp candidates so that they conform more closely to the shape of actual polyps. The restructuring process causes false positives to expand to include more false positive characteristics, whereas, actual polyps retain their original polyp-like characteristics. An evaluation of the documented technique demonstrated that it can be successfully applied to the majority of polyp candidates, and that its use can reduce the number of false positive detections by up to 57.8%

    The use of 3D surface fitting for robust polyp detection and classification in CT colonography

    Get PDF
    In this paper we describe the development of a computationally efficient computer-aided detection (CAD) algorithm based on the evaluation of the surface morphology that is employed for the detection of colonic polyps in computed tomography (CT) colonography. Initial polyp candidate voxels were detected using the surface normal intersection values. These candidate voxels were clustered using the normal direction, convexity test, region growing and Gaussian distribution. The local colonic surface was classified as polyp or fold using a feature normalized nearest neighbor-hood classifier. The main merit of this paper is the methodology applied to select the robust features derived from the colon surface that have a high discriminative power for polyp/fold classification. The devised polyp detection scheme entails a low computational overhead (typically takes 2.20 minute per dataset) and shows 100% sensitivity for phantom polyps greater than 5mm. It also shows 100% sensitivity for real polyps larger than 10mm and 91.67% sensitivity for polyps between 5 to 10mm with an average of 4.5 false positives per dataset. The experimental data indicates that the proposed CAD polyp detection scheme outperforms other techniques that identify the polyps using features that sample the colon surface curvature especially when applied to low-dose datasets

    A fully automatic CAD-CTC system based on curvature analysis for standard and low-dose CT data

    Get PDF
    Computed tomography colonography (CTC) is a rapidly evolving noninvasive medical investigation that is viewed by radiologists as a potential screening technique for the detection of colorectal polyps. Due to the technical advances in CT system design, the volume of data required to be processed by radiologists has increased significantly, and as a consequence the manual analysis of this information has become an increasingly time consuming process whose results can be affected by inter- and intrauser variability. The aim of this paper is to detail the implementation of a fully integrated CAD-CTC system that is able to robustly identify the clinically significant polyps in the CT data. The CAD-CTC system described in this paper is a multistage implementation whose main system components are: 1) automatic colon segmentation; 2) candidate surface extraction; 3) feature extraction; and 4) classification. Our CAD-CTC system performs at 100% sensitivity for polyps larger than 10 mm, 92% sensitivity for polyps in the range 5 to 10 mm, and 57.14% sensitivity for polyps smaller than 5 mm with an average of 3.38 false positives per dataset. The developed system has been evaluated on synthetic and real patient CT data acquired with standard and low-dose radiation levels

    Progettazione di un sistema CAD per le colonscopie virtuali

    Get PDF
    Il lavoro di tesi &egrave consistito nella progettazione e nell'implementazione di un sistema di computer assisted diagnosis per l'ispezione e la manipolazione di dataset volumetrici di tipo biomedico. Il sistema &egrave stato inoltre specializzato e sperimentato su colonscopie virtuali

    Automatic colonic polyp detection using curvature analysis for standard and low dose CT data

    Get PDF
    Colon cancer is the second leading cause of cancer related deaths in the developed nations. Early detection and removal of colorectal polyps via screening is the most effective way to reduce colorectal cancer (CRC) mortality. Computed Tomography Colonography (CTC) or Virtual Colonoscopy (VC) is a rapidly evolving non-invasive technique and the medical community view this medical procedure as an alternative to the standard colonoscopy for the detection of colonic polyps. In CTC the first step for automatic polyp detection for 3D visualization of the colon structure and automatic polyp detection addresses the segmentation of the colon lumen. The segmentation of colon lumen is far from a trivial task as in practice many datasets are collapsed due to incorrect patient preparation or blockages caused by residual water/materials left in the colon. In this thesis a robust multi-stage technique for automatic segmentation of the colon is proposed tha t maximally uses the anatomical model of a generic colon. In this regard, the colon is reconstructed using volume by length analysis, orientation, length, end points, geometrical position in the volumetric data, and gradient of the centreline of each candidate air region detected in the CT data. The proposed method was validated using a total of 151 standard dose (lOOmAs) and 13 low-dose (13mAs-40mAs) datasets and the collapsed colon surface detection was always higher than 95% with an average of 1.58% extra colonic surface inclusion. The second major step of automated CTC attempts the identification of colorectal polyps. In this thesis a robust method for polyp detection based on surface curvature analysis has been developed and evaluated. The convexity of the segmented colon surface is sampled using the surface normal intersection, Hough transform, 3D histogram, Gaussian distribution, convexity constraint and 3D region growing. For each polyp candidate surface the morphological and statistical features are extracted and the candidate surface is classified as a polyp/fold structure using a Feature Normalized Nearest Neighbourhood classifier. The devised polyp detection scheme entails a low computational overhead (typically takes 3.60 minute per dataset) and shows 100% sensitivity for polyps larger than 10mm, 92% sensitivity for polyps in the range 5 to 10mm and 64.28% sensitivity for polyp smaller than 5mm. The developed technique returns in average 4.01 false positives per dataset. The patient exposure to ionising radiation is the major concern in using CTC as a mass screening technique for colonic polyp detection. A reduction of the radiation dose will increase the level of noise during the acquisition process and as a result the quality of the CT d a ta is degraded. To fully investigate the effect of the low-dose radiation on the performance of automated polyp detection, a phantom has been developed and scanned using different radiation doses. The phantom polyps have realistic shapes (sessile, pedunculated, and flat) and sizes (3 to 20mm) and were designed to closely approximate the real polyps encountered in clinical CT data. Automatic polyp detection shows 100% sensitivity for polyps larger than 10mm and shows 95% sensitivity for polyps in the range 5 to 10mm. The developed method was applied to CT data acquired at radiation doses between 13 to 40mAs and the experimental results indicate th a t robust polyp detection can be obtained even at radiation doses as low as 13mAs
    corecore