    Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature

    Get PDF
    © 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe

    Design of a Haptic Interface for Medical Applications using Magneto-Rheological Fluid based Actuators

    Get PDF
    This thesis reports on the design, construction, and evaluation of a prototype two degrees-of-freedom (DOF) haptic interface, which takes advantage of Magneto-Rheological Fluid (MRF) based clutches for actuation. Haptic information provides important cues in teleoperated systems and enables the user to feel the interaction with a remote or virtual environment during teleoperation. The two main objectives in designing a haptic interface are stability and transparency. Indeed, deficiencies in these factors in haptics-enabled telerobotic systems has the introduction of haptics in medical environments where safety and reliability are prime considerations. An actuator with poor dynamics, high inertia, large size, and heavy weight can significantly undermine the stability and transparency of a teleoperated system. In this work, the potential benefits of MRF-based actuators to the field of haptics in medical applications are studied. Devices developed with such fluids are known to possess superior mechanical characteristics over conventional servo systems. These characteristics significantly contribute to improved stability and transparency of haptic devices. This idea is evaluated and verified through both theoretical and experimental points of view. The design of a small-scale MRF-based clutch, suitable for a multi-DOF haptic interface, is discussed and its performance is compared with conventional servo systems. This design is developed into four prototype clutches. In addition, a closed-loop torque control strategy is presented. The feedback signal used in this control scheme comes from the magnetic field acquired from embedded Hall sensors in the clutch. The controller uses this feedback signal to compensate for the nonlinear behavior using an estimated model, based on Artificial Neural Networks. Such a control strategy eliminates the need for torque sensors for providing feedback signals. The performance of the developed design and the effectiveness of the proposed modeling and control techniques are experimentally validated. Next, a 2-DOF haptic interface based on a distributed antagonistic configuration of MRF-based clutches is constructed for a class of medical applications. This device is incorporated in a master-slave teleoperation setup that is used for applications involving needle insertion and soft-tissue palpation. Phantom and in vitro animal tissue were used to assess the performance of the haptic interface. The results show a great potential of MRF-based actuators for integration in haptic devices for medical interventions that require reliable, safe, accurate, highly transparent, and stable force reflection

    METHODS, SYSTEMS, AND DEVICES RELATING TO FORCE CONTROL SURGICAL SYSTEMS

    Get PDF
    The various embodiments herein relate to robotic surgical systems and devices that use force and/or torque sensors to measure forces applied at various components of the system or device. Certain implementations include robotic surgical devices having one or more force/torque sensors that detect or measure one or more forces applied at or on one or more arms. Other embodiments relate to systems having a robotic surgical device that has one or more sensors and an external controller that has one or more motors such that the sensors transmit information that is used at the controller to actuate the motors to provide haptic feedback to a user

    Turing-Test Evaluation of a Mobile Haptic Virtual Reality Kissing Machine

    Get PDF
    Various communication systems have been developed to integrate the haptic channel in digital communication. Future directions of such haptic technologies are moving towards realistic virtual reality applications and human-robot social interaction. With the digitisation of touch, robots equipped with touch sensors and actuators can communicate with humans on a more emotional and intimate level, such as sharing a hug or kiss just like humans do. This paper presents the design guideline, implementation and evaluations of a novel haptic kissing machine for smart phones - the Kissenger machine. The key novelties and contributions of the paper are: (i) A novel haptic kissing device for mobile phones, which uses dynamic perpendicular force stimulation to transmit realistic sensations of kissing in order to enhance intimacy and emotional connection of digital communication; (ii) Extensive evaluations of the Kissenger machine, including a lab experiment that compares mediated kissing with Kissenger to real kissing, a unique haptic Turing test that involves the first academic study of humanmachine kiss, and a field study of the effects of Kissenger on long distance relationships

    Robotic Exoskeletons for Upper Extremity Rehabilitation

    Get PDF

    Haptic Interface for the Simulation of Endovascular Interventions

    Get PDF
    Endovascular interventions are minimally invasive surgical procedures that are performed to diagnose and treat vascular diseases. These interventions use a combination of long and flexible instruments known as guidewire and catheter. A popular method of developing the skills required to manipulate the instruments successfully is through the use of virtual reality (VR) simulators. However, the interfaces of current VR simulators have several shortcomings due to limitations in the instrument tracking and haptic feedback systems design. A major challenge of developing physics-based training simulations of endovascular interventional procedures is to unobtrusively access the central, co-axial guidewire for tracking and haptics. This work sets out to explore the state of the art, to identify and develop novel solutions to this concentric occlusion problem, and to perform a validation of a proof of concept prototype. This multi port haptic interface prototype has been integrated with a 3-D virtual environment and features novel instrument tracking and haptic feedback actuation systems. The former involves the use of an optical sensor to detect guidewire movements through a clear catheter, whereas the latter utilises the placement of a customised electromagnetic actuator within the catheter hub. During the proof of concept validation process, both systems received positive reviews. Whilst the haptic interface prototype designed in this work has met the original objectives, there are still important aspects which need to be addressed to improve its content and face validity. With further development, the prototype has the potential to evolve and become a significant improvement over the haptic interfaces that exist today.Open Acces