A secondary measurement standard filling the gap between the available static and dynamic standards was developed. The standard utilizes a quick-opening valve and bursting diaphragms to generate step-like pressures with amplitude of few kilopascals to 10Â MPa and with frequency content from 10-2 Hz to 800Â Hz. An important design feature of the developed standard lies in the usage of aluminium diaphragms, allowing short rise times and high frequency content. The standard is based on two reference sensors, calibrated statically and dynamically. The reference sensors showed a linear dynamic response in the intermediate frequency range and was in good agreement with the static calibration results. Therefore, extrapolation of shock tube results was implemented. To demonstrate the capabilities of the developed standard, three pressure measurement systems were characterized, and their respective dynamic response was calculated. The results show that the developed standard can provide calibration information that are not currently available.The financial support by the Swedish Governmental Agency for Innovation Systems, VINNOVA [grant number 2021-04166] is gratefully acknowledged.</p