The purpose of the study is to test a weakly basic anion exchanger of the polycondensation type in the processes of sorption of ions of copper, nickel, cobalt, zinc, cadmium. Among the indicated metal ions, the maximum sorption was established for copper ions.
To study the process of sorption of copper ions by the tested anion exchanger, the method of potentiometric titration was used. It was found that copper ions are sorbed by the anion exchanger in the form of a complex in the range of pH = 3,4-4,2. The formation of the copper ions complexes decreases with an increase of the pH value in the equilibrium solution. In an alkaline medium, there is no complexation process, and copper ions form hydroxides