Abstract

BACKGROUND: The primary colorectal cancer screening test in England is a guaiac faecal occult blood test (gFOBt). The NHS Bowel Cancer Screening Programme (BCSP) interprets tests on six samples on up to three test kits to determine a definitive positive or negative result. However, the test algorithm fails to achieve a definitive result for a significant number of participants because they do not comply with the programme requirements. This study identifies factors associated with failed compliance and modifications to the screening algorithm that will improve the clinical effectiveness of the screening programme. METHODS: The BCSP Southern Hub data for screening episodes started in 2006–2012 were analysed for participants aged 60–69 years. The variables included age, sex, level of deprivation, gFOBt results and clinical outcome. RESULTS: The data set included 1 409 335 screening episodes; 95.08% of participants had a definitively normal result on kit 1 (no positive spots). Among participants asked to complete a second or third gFOBt, 5.10% and 4.65%, respectively, failed to return a valid kit. Among participants referred for follow up, 13.80% did not comply. Older age was associated with compliance at repeat testing, but non-compliance at follow up. Increasing levels of deprivation were associated with non-compliance at repeat testing and follow up. Modelling a reduction in the threshold for immediate referral led to a small increase in completion of the screening pathway. CONCLUSIONS: Reducing the number of positive spots required on the first gFOBt kit for referral for follow-up and targeted measures to improve compliance with follow-up may improve completion of the screening pathway