Results are presented from a small-scale experiment to investigate the use of
room temperature organic liquid scintillators as the active medium for a time
projection chamber (TPC). The optical properties of liquid scintillators have
long been known, but their ability to transport charge has remained, until now,
largely untested. The idea of using room temperature liquids as an active
medium for an ionisation chamber was first presented in \cite{EnglerTMS}. Since
then the range of liquid scintillators available has been greatly developed. We
present successful transport of ionization charges in a selection of both, pure
organic liquid solvents and liquid scintillator cocktails over 20mm using a
variety of electric drift field strengths. The target of this research is to
offer a cost effective alternative to liquid noble gas detectors in neutrino
physics.Comment: 6 pages, 5 figures, submitted to Proceedings 12th Pisa Meeting on
Advanced Detectors, La Biodola, Isola d'Elba, Ital