research

The Influence of Different Obturation Systems on the Fracture Resistance of Endodontically Treated Roots. An in Vitro Study

Abstract

This study aimed to compare the fracture resistance of endodontically treated roots filled by different obturation systems. Material and methods: Ninety-six upper central incisors were used and decoronated, retaining 12 mm of the roots. On the basis of obturation systems, the roots were divided into 4 groups (n=24): Group1 (COGR): control group (unprepared, unfilled), Group 2 (AVGR): ActiV GP points/ActiV GP sealer, Group3 (GPGR): Gutta percha points/AH plus sealer, and Group4 (GAGR): Gutta percha points/ActiV GP sealer. The last three groups were obturated with the single cone technique. The roots were then stored in 100% relative humidity at 37 °C for 2 weeks. A vertical compressive force was exerted with a universal testing machine until a fracture occurred. Data were statistically analyzed with one-way ANOVA. Results: Mean (SD) failure loads for groups ranged from 920.51 ± 210.37 to 1113.44 ± 489.42 N. The fracture resistance between the different study groups indicated no statistical difference. Conclusions: ActiV GP system did not exert a significant effect on the fracture resistance of endodontically treated teeth

    Similar works

    Full text

    thumbnail-image

    Available Versions

    Last time updated on 10/04/2018