We describe the neutron polarimeter NPOL3 for the measurement of polarization
transfer observables Dij with a typical high resolution of ∼300 keV
at Tn≃ 200 MeV.
The NPOL3 system consists of three planes of neutron detectors.
The first two planes for neutron polarization analysis are made of 20 sets of
one-dimensional position-sensitive plastic scintillation counters with a size
of 100 cm × 10 cm × 5 cm, and they cover the area of 100 ×
100 cm2.
The last plane for detecting doubly scattered neutrons or recoiled protons is
made of the two-dimensional position-sensitive liquid scintillation counter
with a size of 100 cm × 100 cm × 10 cm.
The effective analyzing powers Ay;eff and double scattering
efficiencies ϵD.S. were measured by using the three kinds
of polarized neutrons from the 2H(p,n)pp, 6Li(p,n)6Be(g.s.), and 12C(p,n)12N(g.s.) reactions at Tp = 198 MeV.
The performance of NPOL3 defined as
ϵD.S.(Ay;eff)2 are similar to that of the
Indiana Neutron POLarimeter (INPOL) by taking into account for the counter
configuration difference between these two neutron polarimeters.Comment: 28 pages, 18 figures, submitted to Nucl. Instrum. Methods Phys. Res.