1,677 research outputs found

    Towards virtual histology with X-ray grating interferometry

    Full text link
    Breast cancer is the most common type of cancer worldwide. Diagnosing breast cancer relies on clinical examination, imaging and biopsy. A core-needle biopsy enables a morphological and biochemical characterization of the cancer and is considered the gold standard for breast cancer diagnosis. A histopathological examination uses high-resolution microscopes with outstanding contrast in the 2D plane, but the spatial resolution in the third, Z-direction, is reduced. In the present paper, we propose two high-resolution table-top systems for phase-contrast X-ray tomography of soft-tissue samples. The first system implements a classical Talbot-Lau interferometer and allows to perform ex-vivo imaging of human breast samples with a voxel size of 5.57 μm. The second system with a comparable voxel size relies on a Sigray MAAST X-ray source with structured anode. For the first time, we demonstrate the applicability of the latter to perform X-ray imaging of human breast specimens with ductal carcinoma in-situ. We assessed image quality of both setups and compared it to histology. We showed that both setups made it possible to target internal features of breast specimens with better resolution and contrast than previously achieved, demonstrating that grating-based phase-contrast X-ray CT could be a complementary tool for clinical histopathology

    Usefulness of optical coherence tomography in the assessment of atherosclerotic culprit lesions in acute coronary syndromes. Comparison with intravascular ultrasound and virtual histology

    Get PDF
    In this paper, we present a case of a female patient with clinically unstable angina pectoris and a bordeline stenosis in the proximal segment of the left anterior descending coronary artery as assessed by coronary angiography and intravascular ultrasound. Virtual histology revealed morphological criteria of a vulnerable plaque forming the culprit lesion. Optical coherence tomography visualized both fibrous cap fracture and a significant stenosis of a coronary artery caused by soft structures identified as mural thrombus covering the plaque surface. The image of atherosclerotic plaque obtained by optical coherence tomography enabled explanation of the cause of coronary instability and influenced subsequent management. The presented case illustrates usefulness of optical coherence tomography as an imaging method complementary to virtual histology and intravascular ultrasound in the diagnostic evaluation of selected patients with acute coronary syndromes. Application of optical coherence tomography in the assessment of vulnerable atherosclerotic plaques is discussed as related to the presented case

    3D virtual histology of murine kidneys-high resolution visualization of pathological alterations by micro computed tomography

    No full text
    The increasing number of patients with end stage chronic kidney disease not only calls for novel therapeutics but also for pioneering research using convincing preclinical disease models and innovative analytical techniques. The aim of this study was to introduce a virtual histology approach using micro computed tomography (mu CT) for the entire murine kidney in order to close the gap between single slice planar histology and a 3D high resolution dataset. An ex vivo staining protocol based on phosphotungstic acid diffusion was adapted to enhance renal soft tissue x-ray attenuation. Subsequent CT scans allowed (i) the detection of the renal cortex, medulla and pelvis in greater detail, (ii) the analysis of morphological alterations, (iii) the quantification of the volume as well as the radio-opacity of these portions and (iv) the quantification of renal fibrotic remodeling based on altered radio-opacity using the unilateral ureteral obstruction model. Thus, virtual histology based on PTA contrast enhanced CT will in future help to refine the outcome of preclinical research on kidney associated murine disease models

    Virtual histology of transgenic mouse embryos for high-throughput phenotyping.

    Get PDF
    Journal ArticleA bold new effort to disrupt every gene in the mouse genome necessitates systematic, interdisciplinary approaches to analyzing patterning defects in the mouse embryo. We present a novel, rapid, and inexpensive method for obtaining high-resolution virtual histology for phenotypic assessment of mouse embryos. Using osmium tetroxide to differentially stain tissues followed by volumetric X-ray computed tomography to image whole embryos, isometric resolutions of 27 mum or 8 mum were achieved with scan times of 2 h or 12 h, respectively, using mid-gestation E9.5-E12.5 embryos. The datasets generated by this method are immediately amenable to state-of-the-art computational methods of organ patterning analysis. This technique to assess embryo anatomy represents a significant improvement in resolution, time, and expense for the quantitative, three-dimensional analysis of developmental patterning defects attributed to genetically engineered mutations and chemically induced embryotoxicity

    Virtual Histology of Transgenic Mouse Embryos for High-Throughput Phenotyping

    Get PDF
    A bold new effort to disrupt every gene in the mouse genome necessitates systematic, interdisciplinary approaches to analyzing patterning defects in the mouse embryo. We present a novel, rapid, and inexpensive method for obtaining high-resolution virtual histology for phenotypic assessment of mouse embryos. Using osmium tetroxide to differentially stain tissues followed by volumetric X-ray computed tomography to image whole embryos, isometric resolutions of 27 μm or 8 μm were achieved with scan times of 2 h or 12 h, respectively, using mid-gestation E9.5–E12.5 embryos. The datasets generated by this method are immediately amenable to state-of-the-art computational methods of organ patterning analysis. This technique to assess embryo anatomy represents a significant improvement in resolution, time, and expense for the quantitative, three-dimensional analysis of developmental patterning defects attributed to genetically engineered mutations and chemically induced embryotoxicity

    Virtual histology of multi-modal magnetic resonance imaging of cerebral cortex in young men

    Get PDF
    Neurobiology underlying inter-regional variations - across the human cerebral cortex - in measures derived with multi-modal magnetic resonance imaging (MRI) is poorly understood. Here, we characterize inter-regional variations in a large number of such measures, including T1 and T2 relaxation times, myelin water fraction (MWF), T1w/T2w ratio, mean diffusivity (MD), fractional anisotropy (FA), magnetization transfer ratio (MTR) and cortical thickness. We then employ a virtual-histology approach and relate these inter-regional profiles to those in cell-specific gene expression. Virtual histology revealed that most MRI-derived measures, including T1, T2 relaxation time, MWF, T1w/T2w ratio, MTR, FA and cortical thickness, are associated with expression profiles of genes specific to CA1 pyramidal cells; these genes are enriched in biological processes related to dendritic arborisation. In addition, T2 relaxation time, MWF and T1w/T2w ratio are associated with oligodendrocyte-specific gene-expression profiles, supporting their use as measures sensitive to intra-cortical myelin. MWF contributes more variance than T1w/T2w ratio to the mean oligodendrocyte expression profile, suggesting greater sensitivity to myelin. These cell-specific MRI associations may help provide a framework for determining which MRI sequences to acquire in studies with specific neurobiological hypotheses
    corecore