7,402 research outputs found

    The intrinsic stiffness of human trabecular meshwork cells increases with senescence.

    Get PDF
    Dysfunction of the human trabecular meshwork (HTM) plays a central role in the age-associated disease glaucoma, a leading cause of irreversible blindness. The etiology remains poorly understood but cellular senescence, increased stiffness of the tissue, and the expression of Wnt antagonists such as secreted frizzled related protein-1 (SFRP1) have been implicated. However, it is not known if senescence is causally linked to either stiffness or SFRP1 expression. In this study, we utilized in vitro HTM senescence to determine the effect on cellular stiffening and SFRP1 expression. Stiffness of cultured cells was measured using atomic force microscopy and the morphology of the cytoskeleton was determined using immunofluorescent analysis. SFRP1 expression was measured using qPCR and immunofluorescent analysis. Senescent cell stiffness increased 1.88±0.14 or 2.57±0.14 fold in the presence or absence of serum, respectively. This was accompanied by increased vimentin expression, stress fiber formation, and SFRP1 expression. In aggregate, these data demonstrate that senescence may be a causal factor in HTM stiffening and elevated SFRP1 expression, and contribute towards disease progression. These findings provide insight into the etiology of glaucoma and, more broadly, suggest a causal link between senescence and altered tissue biomechanics in aging-associated diseases

    A comparative study of the elastic fibre system within the mouse and human cornea

    Get PDF
    The cornea relies on its organised extracellular matrix for maintaining transparency and biomechanical strength. Studies have identified an elastic fibre system within the human posterior cornea, thought to allow for slight deformations in response to internal pressure fluctuations within the eye. However, the type of elastic fibres that exist within the cornea and their roles remain elusive. The aim of this study was to compare the distribution and organisation of the elastic fibres within the posterior peripheral mouse and human cornea, and elucidate how these fibres integrate with the trabecular meshwork, whilst characterising the distribution of their main likely components (fibrillin-1, elastin and type VI collagen) in different parts of the cornea and adjacent sclera. We identified key differences in the elastic fibre system between the human and mouse cornea. True elastic fibres (containing elastin) were identified within the human posterior peripheral cornea. Elastic fibres appeared to present as an extensive network throughout the mouse corneal stroma, but as fibrillin-rich microfibril bundles rather than true elastic fibres. However, tropoelastin staining indicated the possibility that true elastic fibres had yet to develop in the young mice studied. Differences were also apparent within the anatomy of the trabecular meshwork. The human trabecular meshwork appeared to insert between the corneal stroma and Descemet's membrane, with elastic fibres continuing into the stroma from the trabecular meshwork anterior to Descemet's membrane. Within the mouse cornea, no clear insertion point of the trabecular meshwork was seen, instead the elastic fibres within the trabecular meshwork continued into Descemet's membrane, with the trabecular meshwork joining posterior to Descemet's membrane

    Aqueous Humor Outflow Structure and Function Imaging At the Bench and Bedside: A Review.

    Get PDF
    Anterior segment glaucoma clinical care and research has recently gained new focus because of novel imaging modalities and the advent of angle-based surgical treatments. Traditional investigation drawn to the trabecular meshwork now emphasizes the entire conventional aqueous humor outflow (AHO) pathway from the anterior chamber to the episcleral vein. AHO investigation can be divided into structural and functional assessments using different methods. The historical basis for studying the anterior segment of the eye and AHO in glaucoma is discussed. Structural studies of AHO are reviewed and include traditional pathological approaches to modern tools such as multi-model two-photon microscopy and optical coherence tomography. Functional assessment focuses on visualizing AHO itself through a variety of non-real-time and real-time techniques such as aqueous angiography. Implications of distal outflow resistance and segmental AHO are discussed with an emphasis on melding bench-side research to viable clinical applications. Through the development of an improved structure: function relationship for AHO in the anterior segment of the normal and diseased eye, a better understanding of the eye with improved therapeutics may be developed

    Angle stability and outflow in dual blade ab interno trabeculectomy with active versus passive chamber management.

    Get PDF
    PurposeTo compare intraoperative angle stability and postoperative outflow of two ab interno trabeculectomy devices that excise the trabecular meshwork with or without active aspiration and irrigation. We hypothesized that anterior segment optical coherence tomography (AS-OCT) allows for a quantitative comparison of intraoperative angle stability in a microincisional glaucoma surgery (MIGS) pig eye training model.MethodsTwelve freshly enucleated porcine eyes were measured with AS-OCT at baseline, at the beginning of the procedure and at its conclusion to determine the anterior chamber depth (ACD) and the nasal angle α in degrees. The right and left eye of pairs were randomly assigned to an active dual blade goniectome (aDBG) and a passive dual blade goniectome (pDBG) group, respectively. The aDBG had irrigation and aspiration ports while the pDBG required surgery under viscoelastic. We performed the procedures using our MIGS training system with a standard, motorized ophthalmic operating microscope. We estimated outflow by obtaining canalograms with fluorescent spheres.ResultsIn aDBG, the nasal angle remained wide open during the procedure at above 90° and did not change towards the end (100±10%, p = 0.9). In contrast, in pDBG, ACD decreased by 51±19% to 21% below baseline (p<0.01) while the angle progressively narrowed by 40±12% (p<0.001). Canalograms showed a similar extent of access to the outflow tract with the aDBG and the pDBG (p = 0.513). The average increase for the aDBG in the superonasal and inferonasal quadrants was between 27 to 31% and for the pDBG between 15 to 18%.ConclusionAS-OCT demonstrated that active irrigation and aspiration improved anterior chamber maintenance and ease of handling with the aDBG in this MIGS training model. The immediate postoperative outflow was equally good with both devices

    Biomechanical, ultrastructural, and electrophysiological characterization of the non-human primate experimental glaucoma model.

    Get PDF
    Laser-induced experimental glaucoma (ExGl) in non-human primates (NHPs) is a common animal model for ocular drug development. While many features of human hypertensive glaucoma are replicated in this model, structural and functional changes in the unlasered portions of trabecular meshwork (TM) of laser-treated primate eyes are understudied. We studied NHPs with ExGl of several years duration. As expected, ExGl eyes exhibited selective reductions of the retinal nerve fiber layer that correlate with electrophysiologic measures documenting a link between morphologic and elctrophysiologic endpoints. Softening of unlasered TM in ExGl eyes compared to untreated controls was observed. The degree of TM softening was consistent, regardless of pre-mortem clinical findings including severity of IOP elevation, retinal nerve fiber layer thinning, or electrodiagnostic findings. Importantly, this softening is contrary to TM stiffening reported in glaucomatous human eyes. Furthermore, microscopic analysis of unlasered TM from eyes with ExGl demonstrated TM thinning with collapse of Schlemm's canal; and proteomic analysis confirmed downregulation of metabolic and structural proteins. These data demonstrate unexpected and compensatory changes involving the TM in the NHP model of ExGl. The data suggest that compensatory mechanisms exist in normal animals and respond to elevated IOP through softening of the meshwork to increase outflow

    A large multi-ethnic genome-wide association study identifies novel genetic loci for intraocular pressure.

    Get PDF
    Elevated intraocular pressure (IOP) is a major risk factor for glaucoma, a leading cause of blindness. IOP heritability has been estimated to up to 67%, and to date only 11 IOP loci have been reported, accounting for 1.5% of IOP variability. Here, we conduct a genome-wide association study of IOP in 69,756 untreated individuals of European, Latino, Asian, and African ancestry. Multiple longitudinal IOP measurements were collected through electronic health records and, in total, 356,987 measurements were included. We identify 47 genome-wide significant IOP-associated loci (P < 5 × 10-8); of the 40 novel loci, 14 replicate at Bonferroni significance in an external genome-wide association study analysis of 37,930 individuals of European and Asian descent. We further examine their effect on the risk of glaucoma within our discovery sample. Using longitudinal IOP measurements from electronic health records improves our power to identify new variants, which together explain 3.7% of IOP variation

    Trabecular Meshwork Gene Expression after Selective Laser Trabeculoplasty

    Get PDF
    BACKGROUND: Trabecular meshwork and Schlemm's canal are the tissues appointed to modulate the aqueous humour outflow from the anterior chamber. The impairment of their functions drives to an intraocular pressure increase. The selective laser trabeculoplasty is a laser therapy of the trabecular meshwork able to decrease intraocular pressure. The exact response mechanism to this treatment has not been clearly delineated yet. The herein presented study is aimed at studying the gene expression changes induced in trabecular meshwork cells by selective laser trabeculoplasty (SLT) in order to better understand the mechanisms subtending its efficacy. METHODOLOGY/PRINCIPAL FINDINGS: Primary human trabecular meshwork cells cultured in fibroblast medium underwent selective laser trabeculoplasty treatment. RNA was extracted from a pool of cells 30 minutes after treatment while the remaining cells were further cultured and RNA was extracted respectively 2 and 6 hours after treatment. Control cells stored in incubator in absence of SLT treatment were used as reference samples. Gene expression was evaluated by hybridization on miRNA-microarray and laser scanner analysis. Scanning electron microscopic examination was performed on 2 Trabecular meshwork samples after SLT at 4(th) and 6(th) hour from treatment. On the whole, selective laser trabeculoplasty modulates in trabecular meshwork the expression of genes involved in cell motility, intercellular connections, extracellular matrix production, protein repair, DNA repair, membrane repair, reactive oxygen species production, glutamate toxicity, antioxidant activities, and inflammation. CONCLUSIONS/SIGNIFICANCE: SLT did not induce any phenotypic alteration in TM samples. TM is a complex tissue possessing a great variety of function pivotal for the active regulation of aqueous humour outflow from the anterior chamber. SLT is able to modulate these functions at the postgenomic molecular level without inducing damage either at molecular or phenotypic levels
    • …
    corecore