137,202 research outputs found

    Features of medical implant passivation using anodic oxide films

    Get PDF
    The passivation ability of metals from groups IV and V of the Periodic Table is considered. Anodic treatment is able to neutralize the increase of metal hardening when comminuting grains to nanometre sizes. The deposition of metal oxide film coatings on a cobalt–chromium alloy surface results in substantial passivation of its surface and prevents cobalt and chromium accumulation in bone tissues. The decrease of surface activity of titanium implants can be achieved both by cleaning the surface during vacuum annealing before oxidation and by the increase of the anodic oxide film thickness, which limits mass and charge transfer through the implant surface. Recommended titanium implant treatment regimens are vacuum annealing at 650 °C and anodic oxidation to attain an oxide thickness less or equal to 300 nm

    Selected fretting-wear-resistant coatings for titanium - 6-percent-aluminum - 4-percent-vanadium alloy

    Get PDF
    A titanium - 6-percent-aluminum - 4-percent-vanadium alloy (Ti-6Al-4V) was subjected to fretting-wear exposures against uncoated Ti-6Al-4V as a baseline and against various coatings and surface treatments applied to Ti-6Al-4V. The coatings evaluated included plasma-sprayed tungsten carbide with 12 percent cobalt, aluminum oxide with 13 percent titanium oxide, chromium oxide, and aluminum bronze with 10 percent aromatic polyester; polymer-bonded polyimide, polyimide with graphite fluoride, polyimide with molybdenum disulfide (MoS2), and methyl phenyl silicone bonded MoS2, preoxidation surface treatment, a nitride surface treatment, and a sputtered MoS2 coating. Results of wear measurements on both the coated and uncoated surfaces after 300,000 fretting cycles indicated that the polyimide coating was the most wear resistant and caused the least wear to the uncoated mating surface

    Pleading Securities Fraud

    Get PDF
    Hyaluronan based hydrogel coatings can mimic extracellular matrix components and incorporate growth factors that can be released during a progressive degradation while new tissue regenerates. This paper describes a structural characterization of a hydrogel coating made of modified hyaluronan polymers and how these coatings interact with bone morphogenetic protein-2 (BMP-2). Quartz crystal microbalance and neutron reflectivity measurements were used for in-situ, real-time measurements of the adsorption properties of polymers and proteins on smooth titanium oxide surfaces that mimic implant products in orthopedics. The adsorption of BMP-2 on a bare titanium oxide surface is compared to that on titanium oxide coated with different chemically modified hyaluronan, the most important being hyaluronan with bisphosphonate groups (HA-BP). The subsequent release of the BMP-2 from these hydrogel coatings could be triggered by calcium ions. The amount of adsorbed protein on the surfaces as well as the amount of released protein both depend on the type of hyaluronan coating. We conclude that HA-BP coated titanium oxide surfaces provide an excellent material for growth factor delivery in-vivo

    Functionalisation of Ti6Al4V and hydroxyapatite surfaces with combined peptides based on KKLPDA and EEEEEEEE peptides

    Get PDF
    Surface modifications are usually performed on titanium alloys to improve osteo-integration and surface bioactivity. Modifications such as alkaline and acid etching, or coating with bioactive materials such as hydroxyapatite, have previously been demonstrated. The aim of this work is to develop a peptide with combined titanium oxide and hydroxyapatite binders in order to achieve a biomimetic hydroxyapatite coating on titanium surfaces. The technology would also be applicable for the functionalisation of titanium and hydroxyapatite surfaces for selective protein adsorption, conjugation of antimicrobial peptides, and adsorption of specialised drugs for drug delivery. In this work, functionalisation of Ti6Al4V and hydroxyapatite surfaces was achieved using combined titanium-hydroxyapatite (Ti-Hap) peptides based on titanium binder (RKLPDA) and hydroxyapatite binder (EEEEEEEE) peptides. Homogeneous peptide coatings on Ti6Al4V surfaces were obtained after surface chemical treatments with a 30 wt % aqueous solution of H2O2 for 24 and 48 hours. The treated titanium surfaces presented an average roughness of Sa=197 nm (24 h) and Sa=128 nm (48 h); an untreated mirror polished sample exhibited an Sa of 13 nm. The advancing water contact angle of the titanium oxide layer after 1 hour of exposure to 30 wt % aqueous solution of H2O2 was around 65°, decreasing gradually with time until it reached 35° after a 48 hour exposure, suggesting that the surface hydrophilicity increased over etching time. The presence of a lysine (L) amino acid in the sequence of the titanium binder resulted in fluorescence intensity roughly 16 % higher compared with the arginine (R) amino acid analogue and therefore the lysine containing titanium binder was used in this work. The Ti-Hap peptide KKLPDAEEEEEEEE (Ti-Hap1) was not adsorbed by the treated Ti6Al4V surfaces and therefore was modified. The modifications involved the inclusion of a glycine spacer between the binding terminals (Ti-Hap2) and the addition of a second titanium binder (KKLPDA) (Ti-Hap3 and Ti-Hap4). The Ti-Hap peptide aptamer which exhibited the strongest intensity after the titanium dip coating was KKLPDAKKLPDAEEEEEEEE (Ti-Hap4). On the other hand, hydroxyapatite surfaces, exhibiting an average roughness of Sa=1.42 µm, showed a higher fluorescence for all peptides compared with titanium surfaces

    Effects of LP-MOCVD prepared TiO2 thin films on the in vitro behavior of gingival fibroblasts

    Get PDF
    We report on the in vitro response of human gingival fibroblasts (HGF-1 cell line) to various thin films of titanium dioxide (TiO2) deposited on titanium (Ti) substrates by low pressure metal-organic chemical vapor deposition (LP-MOCVD). The aim was to study the influence of film structural parameters on the cell behavior comparatively with a native-oxide covered titanium specimen, this objective being topical and interesting for materials applications in implantology. HGF-1 cells were cultured on three LP-MOCVD prepared thin films of TiO2 differentiated by their thickness, roughness, transversal morphology, allotropic composition and wettability, and on a native-oxide covered Ti substrate. Besides traditional tests of cell viability and morphology, the biocompatibility of these materials was evaluated by fibronectin immunostaining, assessment of cell proliferation status and the zymographic evaluation of gelatinolytic activities specific to matrix metalloproteinases secreted by cells grown in contact with studied specimens. The analyzed surfaces proved to influence fibronectin fibril assembly, cell proliferation and capacity to degrade extracellular matrix without considerably affecting cell viability and morphology. The MOCVD of TiO2 proved effective in positively modifying titanium surface for medical applications. Surface properties playing a crucial role for cell behavior were the wettability and, secondarily, the roughness, HGF-1 cells preferring a moderately rough and wettable TiO2 coating

    Surface characterization

    Get PDF
    The biocompatibility of commercially pure titanium and its alloys is closely related to their surface properties, with both the composition of the protecting oxide film and the surface topography playing an important role. Surfaces of commercially pure titanium and of the two alloys Ti-6Al-7Nb and Ti-6Al-4V (wt %) have been investigated following three different pretreatments: polishing, nitric acid passivation and pickling in nitric acid-hydrogen fluoride. Nitric acid treatment is found to substantially reduce the concentration of surface contaminants present after polishing. The natural 4-6 nm thick oxide layer on commercially pure titanium is composed of titanium oxide in different oxidation states (TiO2, Ti2O3 and TiO), while for the alloys, aluminium and niobium or vanadium are additionally present in oxidized form (Al2O3, Nb2O5 or V-oxides). The concentrations of the alloying elements at the surface are shown to be strongly dependent on the pretreatment process. While pickling increases the surface roughness of both commercially pure titanium and the alloys, different mechanisms appear to be involved. In the case of commercially pure titanium, the dissolution rate depends on grain orientation, whereas in the case of the two alloys, selective α-phase dissolution and enrichment of the β-phase appears to occur. © 1999 Kluwer Academic Publisher

    Influence of Titanium Oxide Pillar Array Nanometric Structures and Ultraviolet Irradiation on the Properties of the Surface of Dental Implants: A Pilot Study

    Get PDF
    Aim: Titanium implants are commonly used as replacement therapy for lost teeth and much current research is focusing on the improvement of the chemical and physical properties of their surfaces in order to improve the osseointegration process. TiO2, when it is deposited in the form of pillar array nanometric structures, has photocatalytic properties and wet surface control, which, together with UV irradiation, provide it with superhydrophilic surfaces, which may be of interest for improving cell adhesion on the peri-implant surface. In this article, we address the influence of this type of surface treatment on type IV and type V titanium discs on their surface energy and cell growth on them. Materials and methods: Samples from titanium rods used for making dental implants were used. There were two types of samples: grade IV and grade V. In turn, within each grade, two types of samples were differentiated: untreated and treated with sand blasting and subjected to double acid etching. Synthesis of the film consisting of titanium oxide pillar array structures was carried out using plasma-enhanced chemical vapor deposition equipment. The plasma was generated in a quartz vessel by an external SLAN-1 microwave source with a frequency of 2.45 GHz. Five specimens from each group were used (40 discs in total). On the surfaces to be studied, the following determinations were carried out: (a) X-ray photoelectron spectroscopy, (b) scanning electron microscopy, (c) energy dispersive X-ray spectroscopy, (d) profilometry, (e) contact angle measurement or surface wettability, (f) progression of contact angle on applying ultraviolet irradiation, and (g) a biocompatibility test and cytotoxicity with cell cultures. Results: The application of ultraviolet light decreased the hydrophobicity of all the surfaces studied, although it did so to a greater extent on the surfaces with the studied modification applied, this being more evident in samples manufactured in grade V titanium. In samples made in grade IV titanium, this difference was less evident, and even in the sample manufactured with grade IV and SLA treatment, the application of the nanometric modification of the surface made the surface optically less active. Regarding cell growth, all the surfaces studied, grouped in relation to the presence or not of the nanometric treatment, showed similar growth. Conclusions. Treatment of titanium oxide surfaces with ultraviolet irradiation made them change temporarily into superhydrophilic ones, which confirms that their biocompatibility could be improved in this way, or at least be maintained

    From art to engineering

    Get PDF
    This paper describes work which emerged through a need to understand more about the potential of laser surface engineering for use in the creative industries. The method of creation of contemporary jewellery pieces and the resultant ‘Ocular’ jewellery series are described from the points of view of an artist and an engineer. The work demonstrates how laser controlled oxide growth on commercially pure titanium under ambient conditions can be used as an artistic tool by producing even, defined colours or by reproducing a simulation of freehand drawings on a titanium surface. It also asks the question: how different are artists from scientists and engineers
    corecore