390,361 research outputs found

    Pixel-tracking derived strain using the GlasgowHeart Method.

    Get PDF
    Background: Estimation of strain parameters from cine acquisitions, such as balanced steady state free precession (b-SSFP) is advantageous, as it would obviate the need for acquisition of additional strain sequences reducing scanning time and making strain more accessible to clinicians. 2D strain derived from feature-tracking is now commercially available. The GlasgowHeart cine-strain method is designed to overcome some limitations of currently available feature-tracking methods by estimating pixel-wise strain for myocardial deformation incorporating all of the myocardial tissues. The aims of this pilot study was to ensure that 2D peak circumferential strain estimated from the GlasgowHeart method is feasible in healthy volunteers (n = 20) and reproducible with minimal intra- and inter- observer variability. Methods: Healthy volunteers aged at least 18 years of age with no prior medical history were invited to participate. A subset of 20 healthy adult volunteers underwent 1.5T CMR twice, < 2 days apart. Written consent was obtained. Mid-LV cine sequences, were analysed with the GlasgowHeart software. The process involves contouring the myocardial borders at end-diastole and segmenting the myocardium by using the right ventricular insertion point according to the 16 segment AHA model. Two observers independently analysed 40 short axis slices using the cine-strain method for inter-observer variability. One observer re-analysed the 40 short axis slices 10 days later for intra-observer variability. Scans were analysed in a random order. Pearson correlation and Bland-Altman analysis were used to analyse the data. Results: 20 participants were used in the subset analysis (mean age ± SD 49.5 years (17.2) 50% male). Peak circumferential strain (Ecc) measured on the first set of MRIs by the two observers (Figure 2A,B) was highly correlated (R = 0.915, p < 0.001) and in excellent agreement (mean difference = 0.01; 95% LoA: -0.01, 0.02). The repeated image analysis (Figure 2C,D) also disclosed a high degree of association in paired measurements of Ecc that was strongly correlated(R= 0.915, p< 0.001) and in excellent agreement (mean difference = 0.00; 95% LoA: -0.02, 0.01). Ecc measured in the second set of MRIs by 2 observers was well correlated (R = 0.937, p < 0.001) and in excellent agreement (mean difference = 0.00; 95% limits of agreement were -0.016 and 0.021). The repeated image analysis at follow-up yielded Ecc that was well correlated(R= 0.942, p < 0.001) and in excellent agreement (mean = 0.00; 95% LoA: -0.009 and 0.009). There was no difference between the average global Ecc at different time points (p > 0.05)

    Validating performance of automotive materials at high strain rate for improved crash design

    Get PDF
    This paper investigates sources of performance variability in high velocity testing of automotive crash structures. Sources of variability, or so called noise factors, present in a testing environment, arise from uncertainty in structural properties, joints, boundary conditions and measurement system. A box structure, which is representative of a crash component, is designed and fabricated from a high strength Dual Phase sheet steel. Crush tests are conducted at low and high speed. Such tests intend to validate a component model and material strain rate sensitivity data determined from high speed tensile testing. To support experimental investigations, stochastic modeling is used to investigate the effect of noise factors on crash structure performance variability, and to identify suitable performance measures to validate a component model and material strain rate sensitivity data. The results of the project will enable the measurement of more reliable strain rate sensitivity data for improved crashworthiness predictions of automotive structures

    Impact of multiscale dynamical processes and mixing on the chemical composition of the upper troposphere and lower stratosphere during the Intercontinental Chemical Transport Experiment–North America

    Get PDF
    We use high-frequency in situ observations made from the DC8 to examine fine-scale tracer structure and correlations observed in the upper troposphere and lower stratosphere during INTEX-NA. Two flights of the NASA DC-8 are compared and contrasted. Chemical data from the DC-8 flight on 18 July show evidence for interleaving and mixing of polluted and stratospheric air masses in the vicinity of the subtropical jet in the upper troposphere, while on 2 August the DC-8 flew through a polluted upper troposphere and a lowermost stratosphere that showed evidence of an intrusion of polluted air. We compare data from both flights with RAQMS 3-D global meteorological and chemical model fields to establish dynamical context and to diagnose processes regulating the degree of mixing on each day. We also use trajectory mapping of the model fields to show that filamentary structure due to upstream strain deformation contributes to tracer variability observed in the upper troposphere. An Eulerian measure of strain versus rotation in the large-scale flow is found useful in predicting filamentary structure in the vicinity of the jet. Higher-frequency (6–24 km) tracer variability is attributed to buoyancy wave oscillations in the vicinity of the jet, whose turbulent dissipation leads to efficient mixing across tracer gradients

    Quantification of left ventricular longitudinal strain, strain rate, velocity and displacement in healthy horses by 2-dimensional speckle tracking

    Get PDF
    Background: The quantification of equine left ventricular (LV) function is generally limited to short-axis M-mode measurements. However, LV deformation is 3-dimensional (3D) and consists of longitudinal shortening, circumferential shortening, and radial thickening. In human medicine, longitudinal motion is the best marker of subtle myocardial dysfunction. Objectives: To evaluate the feasibility and reliability of 2-dimensional speckle tracking (2DST) for quantifying equine LV longitudinal function. Animals: Ten healthy untrained trotter horses; 9.6 +/- 4.4 years; 509 +/- 58 kg. Methods : Prospective study. Repeated echocardiographic examinations were performed by 2 observers from a modified 4-chamber view. Global, segmental, and averaged peak values and timing of longitudinal strain (SL), strain rate (SrL), velocity (VL), and displacement (DL) were measured in 4 LV wall segments. The inter- and intraobserver within- and between-day variability was assessed by calculating the coefficients of variation for repeated measurements. Results: 2DST analysis was feasible in each exam. The variability of peak systolic values and peak timing was low to moderate, whereas peak diastolic values showed a higher variability. Significant segmental differences were demonstrated. DL and VL presented a prominent base-to-midwall gradient. SL and SrL values were similar in all segments except the basal septal segment, which showed a significantly lower peak SL occurring about 60 ms later compared with the other segments. Conclusions and Clinical Importance 2DST is a reliable technique for measuring systolic LV longitudinal motion in healthy horses. This study provides preliminary reference values, which can be used when evaluating the technique in a clinical setting

    Highly reproducible, hysteresis-free, flexible strain sensors by inkjet printing of carbon nanotubes

    No full text
    In order to build upon the exceptional interest for flexible sensors based on carbon nanotube networks (CNNs), the field requires high device-to-device reproducibility. Inkjet printing has provided outstanding results for flexible ohmic sensors in terms of reproducibility of their resistance. However, the reproducibility of the sensitivity, the most critical parameter for sensing application, has been only marginally assessed. In the present paper, CNN based resistive strain sensors fabricated by inkjet-printing on flexible Ethylene Tetrafluoroethylene (EFTE) sheets are presented. The variability on the device initial resistance is studied for 5 different batches of sensors from 3 to 72 devices each. The variability ranges between 8.4% and 43% depending on the size of the batches, with a 20% average. An 8-device batch with 15% variability on initial resistance is further studied for variability on the strain and thermal sensitivity. Standard deviation values are found to be as low as 16% on the strain sensitivity and 8% on the temperature sensitivity. Moreover, the devices are hysteresis free, a rare achievement for CNT strain sensors on plastics

    Assessment of Left Atrial Deformation and Function by 2-Dimensional Speckle Tracking Echocardiography in Healthy Dogs and Dogs With Myxomatous Mitral Valve Disease

    Get PDF
    open7noBackground: The assessment of left atrial (LA) function by 2-dimensional speckle tracking echocardiography (STE) holds important clinical implications in human medicine. Few similar data are available in dogs. Objectives: To assess LA function by STE in dogs with and without myxomatous mitral valve disease (MMVD), analyzing LA areas, systolic function, and strain. Animals: One hundred and fifty dogs were divided according to the American College of Veterinary Internal Medicine classification of heart failure: 23 dogs in class A, 52 in class B1, 36 in class B2, and 39 in class C + D. Methods: Prospective observational study. Conventional morphologic and Doppler variables, LA areas, and STE-based LA strain analysis were performed in all dogs and results were compared among groups. Correlation analysis was carried out between LA STE variables and other echocardiographic variables. Results: Variability study showed good reproducibility for all the tested variables (coefficient of variation <16%). Left atrial areas, fractional area change, peak atrial longitudinal strain (PALS), peak atrial contraction strain, and contraction strain index (CSI) differed significantly between groups B2 and C + D and all the other groups (overall P < .001), whereas only PALS differed between groups B1 and A (P = .01). Left atrial areas increased with progression of the disease, whereas LA functional parameters decreased. Only CSI increased nonsignificantly from group A to group B1 and then progressively decreased. Thirty-one significant correlations (P < .001, r > .3) were found between conventional left heart echocardiographic variables and LA areas and strain variables. Conclusions and Clinical Importance: Left atrial STE analysis provides useful information on atrial function in the dog, highlighting a progressive decline in atrial function with worsening of MMVD.openBaron Toaldo, M; Romito, G.; Guglielmini, C.; Diana, A.; Pelle, N.G.; Contiero, B.; Cipone, M.Baron Toaldo, M; Romito, G.; Guglielmini, C.; Diana, A.; Pelle, N.G.; Contiero, B.; Cipone, M

    Modeling microevolution in a changing environment: The evolving quasispecies and the Diluted Champion Process

    Full text link
    Several pathogens use evolvability as a survival strategy against acquired immunity of the host. Despite their high variability in time, some of them exhibit quite low variability within the population at any given time, a somehow paradoxical behavior often called the evolving quasispecies. In this paper we introduce a simplified model of an evolving viral population in which the effects of the acquired immunity of the host are represented by the decrease of the fitness of the corresponding viral strains, depending on the frequency of the strain in the viral population. The model exhibits evolving quasispecies behavior in a certain range of its parameters, ans suggests how punctuated evolution can be induced by a simple feedback mechanism.Comment: 15 pages, 12 figures. Figures redrawn, some additional clarifications in the text. To appear in Journal of Statistical Mechanics: Theory and Experimen
    corecore