89,851 research outputs found

    High Linearity SAR ADC for Smart Sensor Applications

    Get PDF
    This paper presents capacitive array optimization technique to improve the Spurious Free Dynamic Range (SFDR) and Signal-to-Noise-and-Distortion Ratio (SNDR) of Successive Approximation Register (SAR) Analog-to-Digital Converter (ADC) for smart sensor application. Monte Carlo simulation results show that capacitive array optimization technique proposed can make the SFDR, SNDR and (Signal-to-Noise Ratio) SNR more concentrated, which means the differences between maximum value and minimum value of SFDR, SNDR and SNR are much smaller than the conventional calibration techniques, more stable performance enhancement can be achieved, and the averaged SFDR is improved from 72.9 dB to 91.1 dB by using the capacitive array optimization method, 18.2 dB improvement of SFDR is obtained with only little expense of digital logic circuits, which makes it good choice for high resolution and high linearity smart sensing systems

    Pre-Interaction Identification by Dynamic Grip Classification

    Get PDF
    We present a novel authentication method to identify users as they pick up a mobile device. We use a combination of back-of-device capacitive sensing and accelerometer measurements to perform classification, and obtain increased performance compared to previous accelerometer-only approaches. Our initial results suggest that users can be reliably identified during the pick-up movement before interaction commences

    Mechanisms and designs of asymmetrical electrochemical capacitors

    Get PDF
    Different charge storage mechanisms in electrochemical energy storage devices are reviewed, including non-Faradaic capacitive, Faradaic capacitive, Faradaic non-capacitive, and their combinations. Specifically, Faradaic capacitive (pseudocapacitive) storage and Faradaic non-capacitive (Nernstian) storage are attributed to the transfer of delocalised and localised valence electrons, respectively. Mathematical and graphical expressions of the respective storage performances are presented. The account is made especially for asymmetrical electrochemical capacitors (AECs), supercapattery and supercabattery. Both hypothetical and experimental examples are presented to demonstrate the merits of supercapattery that combines capacitive and Nernstian electrodes. Enhanced storage performance is shown by properly pairing and balancing the properties of the negatrode (negative electrode) and positrode (positive electrode) in the AEC or supercapattery. In addition, the design, laboratory manufacturing and performance of several stacks of bipolarly connected AEC cells are assessed in terms of commercial feasibility and promise

    Wearable Capacitive-based Wrist-worn Gesture Sensing System

    Get PDF
    Gesture control plays an increasingly significant role in modern human-machine interactions. This paper presents an innovative method of gesture recognition using flexible capacitive pressure sensor attached on user’s wrist towards computer vision and connecting senses on fingers. The method is based on the pressure variations around the wrist when the gesture changes. Flexible and ultrathin capacitive pressure sensors are deployed to capture the pressure variations. The embedding of sensors on a flexible substrate and obtain the relevant capacitance require a reliable approach based on a microcontroller to measure a small change of capacitive sensor. This paper is addressing these challenges, collect and process the measured capacitance values through a developed programming on LabVIEW to reconstruct the gesture on computer. Compared to the conventional approaches, the wrist-worn sensing method offerings a low-cost, lightweight and wearable prototype on the user’s body. The experimental result shows that the potentiality and benefits of this approach and confirms that accuracy and number of recognizable gestures can be improved by increasing number of sensor

    Capacitive sensing of droplets for microfluidic devices based on thermocapillary actuation

    Get PDF
    The design and performance of a miniaturized coplanar capacitive sensor is presented whose electrode arrays can also function as resistive microheaters for thermocapillary actuation of liquid films and droplets. Optimal compromise between large capacitive signal and high spatial resolution is obtained for electrode widths comparable to the liquid film thickness measured, in agreement with supporting numerical simulations which include mutual capacitance effects. An interdigitated, variable width design, allowing for wider central electrodes, increases the capacitive signal for liquid structures with non-uniform height profiles. The capacitive resolution and time response of the current design is approximately 0.03 pF and 10 ms, respectively, which makes possible a number of sensing functions for nanoliter droplets. These include detection of droplet position, size, composition or percentage water uptake for hygroscopic liquids. Its rapid response time allows measurements of the rate of mass loss in evaporating droplets

    Locoregional hyperthermia of deep-seated tumours applied with capacitive and radiative systems. A simulation study

    Get PDF
    Background: Locoregional hyperthermia is applied to deep-seated tumours in the pelvic region. Two very different heating techniques are often applied: capacitive and radiative heating. In this paper, numerical simulations are applied to compare the performance of both techniques in heating of deep-seated tumours. Methods: Phantom simulations were performed for small (30 × 20 × 50 cm 3 ) and large (45 × 30 × 50 cm 3 ), homogeneous fatless and inhomogeneous fat-muscle, tissue-equivalent phantoms with a central or eccentric target region. Radiative heating was simulated with the 70 MHz AMC-4 system and capacitive heating was simulated at 13.56 MHz. Simulations were performed for small fatless, small (i.e. fat layer typically 3 cm) patients with cervix, prostate, bladder and rectum cancer. Temperature distributions were simulated using constant hyperthermic-level perfusion values with tissue constraints of 44 °C and compared for both heating techniques. Results: For the small homogeneous phantom, similar target heating was predicted with radiative and capacitive heating. For the large homogeneous phantom, most effective target heating was predicted with capacitive heating. For inhomogeneous phantoms, hot spots in the fat layer limit adequate capacitive heating, and simulated target temperatures with radiative heating were 2–4 °C higher. Patient simulations predicted therapeutic target temperatures with capacitive heating for fatless patients, but radiative heating was more robust for all tumour sites and patient sizes, yielding target temperatures 1–3 °C higher than those predicted for capacitive heating. Conclusion: Generally, radiative locoregional heating yields more favourable simulated temperature distributions for deep-seated pelvic tumours, compared with capacitive heating. Therapeutic temperatures are predicted for capacitive heating in patients with (almost) no fat

    Finite element modelling of electrostatic fields in process tomography capacitive electrode systems for flow response evaluation

    Get PDF
    Various aspects and results of 2-D finite element (FE) modeling of electrostatic fields in 12-electrode capacitive systems for two-phase flow imaging are described. The capacitive technique relies on changes in capacitances between electrodes (mounted on the outer surface of the flow pipe) due to the change in permittivities of flow components. The measured capacitances between various electrode pairs and the field computation data are used to reconstruct the cross sectional image of the flow components. FE modeling of the electric field is necessary to optimize design variables and evaluate the system response to various flow regimes, likely to be encountered in practice. Results are presented in terms of normalized capacitances for various flow regimes. The effects of key geometric parameters of the electrode system are presented and analyzed

    Thermodynamics of Ion Separation by Electrosorption

    Full text link
    We present a simple, top-down approach for the calculation of minimum energy consumption of electrosorptive ion separation using variational form of the (Gibbs) free energy. We focus and expand on the case of electrostatic capacitive deionization (CDI), and the theoretical framework is independent of details of the double-layer charge distribution and is applicable to any thermodynamically consistent model, such as the Gouy-Chapman-Stern (GCS) and modified Donnan (mD) models. We demonstrate that, under certain assumptions, the minimum required electric work energy is indeed equivalent to the free energy of separation. Using the theory, we define the thermodynamic efficiency of CDI. We explore the thermodynamic efficiency of current experimental CDI systems and show that these are currently very low, less than 1% for most existing systems. We applied this knowledge and constructed and operated a CDI cell to show that judicious selection of the materials, geometry, and process parameters can be used to achieve a 9% thermodynamic efficiency (4.6 kT energy per removed ion). This relatively high value is, to our knowledge, by far the highest thermodynamic efficiency ever demonstrated for CDI. We hypothesize that efficiency can be further improved by further reduction of CDI cell series resistances and optimization of operational parameters

    Fingerprint verification by fusion of optical and capacitive sensors

    Get PDF
    A few works have been presented so far on information fusion for fingerprint verification. None, however, have explicitly investigated the use of multi-sensor fusion, in other words, the integration of the information provided by multiple devices to capture fingerprint images. In this paper, a multi-sensor fingerprint verification system based on the fusion of optical and capacitive sensors is presented. Reported results show that such a multi-sensor system can perform better than traditional fingerprint matchers based on a single sensor. (C) 2004 Elsevier B.V. All rights reserved
    corecore