3,378,614 research outputs found
Diferencias entre modelos geoestadisticos aplicados en el análisis de la distribución espacio-temporal de especies biológicas
Spin squeezing: transforming one-axis-twisting into two-axis-twisting
Squeezed spin states possess unique quantum correlation or entanglement that
are of significant promises for advancing quantum information processing and
quantum metrology. In recent back to back publications [C. Gross \textit{et al,
Nature} \textbf{464}, 1165 (2010) and Max F. Riedel \textit{et al, Nature}
\textbf{464}, 1170 (2010)], reduced spin fluctuations are observed leading to
spin squeezing at -8.2dB and -2.5dB respectively in two-component atomic
condensates exhibiting one-axis-twisting interactions (OAT). The noise
reduction limit for the OAT interaction scales as , which
for a condensate with atoms, is about 100 times below standard
quantum limit. We present a scheme using repeated Rabi pulses capable of
transforming the OAT spin squeezing into the two-axis-twisting type, leading to
Heisenberg limited noise reduction , or an extra 10-fold
improvement for .Comment: 4 pages, 3 figure
Three axis controller Patent
Unitary three-axis controller for flight vehicles within or outside atmospher
Occludin Content Modulates Hydrogen Peroxide–Induced Increase in Renal Epithelial Paracellular Permeability
The ability of hydrogen peroxide (H2O2) to increase paracellular permeability of renal epithelial cell monolayers was examined and the role of occludin in this regulation was investigated. H2O2 treatment increased the paracellular movement of calcein, a marker for the leak pathway permeability, across monolayers of two renal epithelial cell lines, MDCK and LLC-PK1, in a concentration-dependent manner. At the same concentrations, H2O2 did not alter transepithelial resistance (TER) nor increase cell death. The magnitude of the H2O2-induced increase in leak pathway permeability was inversely related to cellular occludin protein content. H2O2 treatment did not produce any major change in total cellular content or Triton X-100-soluble or -insoluble fraction content of occludin protein. Occludin protein staining at the tight junction region was diminished following H2O2 treatment. The most dramatic effect of H2O2 was on the dynamic mobility of GFP-occludin into the tight junction region. H2O2 treatment slowed lateral movement of GFP-occludin into the tight junction region but not on the apical membrane. Further, removal of the cytoplasmic C-terminal region of occludin protein eliminated the effect of H2O2 on GFP-occludin lateral movement into the tight junction region. An increase in the mobile fraction of GFP-occludin was associated with a loss of response to H2O2. These data indicate that the H2O2-induced increase in renal epithelial cell paracellular permeability is mediated, at least in part, through occludin protein, possibly through a slowing of the rate of occludin movement into the tight junction region
Multiple axis reticle
A reticle permits the alignment of three orthogonal axes (X, Y and Z) that intersect at a common target point. Thin, straight filaments are supported on a frame. The filaments are each contained in a different orthogonal plane (S sub xy, S sub xz, and S sub yz) and each filament intersects two of the three orthogonal axes. The filaments, as viewed along the frame axis, give the appearance of a triangle with a V extending from each triangle vertex. When axial alignment is achieved, the filament portions adjacent to a triangle vertex are seen (along the axis of interest) as a right-angle cross, whereas these filament portions are seen to intersect at an oblique angle when axial misalignment occurs. The reticle is open in the region near the target point leaving ample space for alignment aids such as a pentaprism or a cube mirror
Long range laser traversing system
The relative azimuth bearing between first and second spaced terrestrial points which may be obscured from each other by intervening terrain is measured by placing at one of the points a laser source for projecting a collimated beam upwardly in the vertical plane. The collimated laser beam is detected at the second point by positioning the optical axis of a receiving instrument for the laser beam in such a manner that the beam intercepts the optical axis. In response to the optical axis intercepting the beam, the beam is deflected into two different ray paths by a beam splitter having an apex located on the optical axis. The energy in the ray paths is detected by separate photoresponsive elements that drive logic networks for proving indications of: (1) the optical axis intercepting the beam; (2) the beam being on the left of the optical axis and (3) the beam being on the right side of the optical axis
A motion-decomposition approach to address gimbal lock in the 3-cylinder open chain mechanism description of a joint coordinate system at the glenohumeral joint
In this study, the standard-sequence properties of a joint coordinate system were implemented for the glenohumeral joint by the use of a set of instantaneous geometrical planes. These are: a plane that is bound by the humeral long axis and an orthogonal axis that is the cross product of the scapular anterior axis and this long axis, and a plane that is bounded by the long axis of the humerus and the cross product of the scapular lateral axis and this long axis. The relevant axes are updated after every decomposition of a motion component of a humeral position. Flexion, abduction and rotation are then implemented upon three of these axes and are applied in a step-wise uncoupling of an acquired humeral motion to extract the joint coordinate system angles. This technique was numerically applied to physiological kinematics data from the literature to convert them to the joint coordinate system and to visually reconstruct the motion on a set of glenohumeral bones for validation
Two-axis controller Patent
Two axis flight controller with potentiometer control shafts directly coupled to rotatable ball member
- …
