456 research outputs found

    Poynting vector, energy density and energy velocity in anomalous dispersion medium

    Get PDF
    The Poynting vector, energy density and energy velocity of light pulses propagating in anomalous dispersion medium (used in WKD-like experiments) are calculated. Results show that a negative energy density in the medium propagates along opposite of incident direction with such a velocity similar to the negative group velocity while the direction of the Poynting vector is positive. In other words, one might say that a positive energy density in the medium would propagate along the positive direction with a speed having approximately the absolute valueof the group velocity. We further point out that neither energy velocity nor group velocity is a good concept to describe the propagation process of light pulse inside the medium in WKD experiment owing to the strong accumulation and dissipation effects.Comment: 6 page

    Phantom-based study exploring the effects of different scatter correction approaches on the reconstructed images generated by contrast-enhanced stationary digital breast tomosynthesis

    Get PDF
    Stationary digital breast tomosynthesis (sDBT) is an emerging technology in which the single rotating x-ray tube is replaced by a fixed array of multiple carbon nanotube-enabled sources, providing a higher spatial and temporal resolution. As such, sDBT offers a promising platform for contrast-enhanced (CE) imaging. However, given the minimal enhancement above background with standard operational tube settings and iodine dosing, CE breast imaging requires additional acquisition steps to isolate the iodine signal, using either temporal or dual energy subtraction (TS or DES) protocols. Also, correcting for factors that limit contrast is critical, and scatter and noise pose unique challenges during tomosynthesis. This phantom-based study of CE sDBT compared different postacquisition scatter correction approaches on the quality of the reconstructed image slices. Beam-pass collimation was used to sample scatter indirectly, from which an interpolated scatter map was obtained for each projection image. Scatter-corrected projections provided the information for reconstruction. Comparison between the application of different scatter maps demonstrated the significant effect that processing has on the contrast-to-noise ratio and feature detectability (d′) in the final displayed images and emphasized the critical importance of scatter correction during DES

    Simulation on system configuration for stationary head CT using linear carbon nanotube x-ray source arrays

    Get PDF
    Purpose: The invention of carbon nanotube (CNT) x-ray source arrays has enabled the development of novel imaging systems, including stationary tomosynthesis and stationary computed tomography (CT) with fast data acquisition, mechanically robust structures, and reduced image blur from source-detector motion. In this work, we report the results of simulation studies of potential system configurations for a stationary head CT (s-HCT) using linear CNT x-ray sources and detector arrays. Approach: We explored s-HCT configurations that utilize one, two, and three linear CNT source arrays. Simulations were implemented using three digital phantoms with both CPU and GPU computing. Sinogram coverage was used for qualitative evaluation of the CT projection collection efficiency for each configuration. A modified low-contrast Shepp-Logan (SL) phantom was implemented for image quality assessment using quantitative metrics. Different iterative reconstruction (IR) methods were compared with both qualitative and quantitative assessments. Results: Sinogram coverage of s-HCT configurations was sensitive to the number of CNT source arrays and geometry. The simulations suggest that a s-HCT configuration with three planes gives near complete sinogram coverage. Such a configuration enables accurate reconstruction of the low-contrast SL phantom and considerably diminished artifacts caused by the system geometry. Conclusions: An optimized s-HCT system configuration with three linear CNT x-ray source arrays is feasible. IR algorithms can diminish artifacts caused by sparse and asymmetrical scans. The proposed s-HCT system configuration is currently under construction

    Multiplexing radiography using a carbon nanotube based x-ray source

    Get PDF
    Speed and temporal resolution are critical for tomographic imaging of objects in rapid motion. Current x-ray scanners record images sequentially in the time domain. The serial approach limits their performance and demands increasingly high x-ray peak power and gantry speed. We have developed a multipixel carbon nanotube based field emission x-ray source that produces spatially and temporally modulated radiations. Using this device we show the feasibility of multiplexing radiography that enables simultaneous collection of multiple projection images using frequency multiplexing. A drastic increase of the speed and reduction of the x-ray peak power are achieved without compromising the imaging quality

    Breast tomosynthesis imaging configuration optimization based on computer simulation

    Get PDF
    Digital tomosynthesis is an innovative imaging technology for early breast cancer detection by providing three-dimensional anatomical information with fast image acquisition and low-dose radiation. Most of current breast tomosynthesis systems utilize a design where a single X-ray tube moves along an arc above objects over a certain angular range. The mechanical movement and patient motion during the scan may degrade image quality. With a carbon nanotube-based multibeam X-ray source, a new breast tomosynthesis modality is innovated, which will potentially produce better image quality with stationary beam sources and faster scan and it enables a variety of beam distributions. In this study, several beam distributions, such as beam sources spanning along a one-dimensional (1-D) parallel configuration and sources over a two-dimensional (2-D) rectangle shape are investigated based on computer simulations. Preliminary results show that 2-D rectangle shapes outperform 1-D parallel shapes by providing better Z-resolution, enhanced image contrast, reduced out-ofplane blur and artifacts and lower reconstruction noise. These benefits may expand tomosynthesis applications to diagnostic and interventional procedures

    Estimating scatter from sparsely measured primary signal

    Get PDF
    Scatter radiation severely degrades the image quality. Measurement-based scatter correction methods sample the scatter signal at sparsely distributed points, from which the scatter profile is estimated and deterministically removed from the projection image. The estimation of the scatter profile is generally done through a spline interpolation and the resulting scatter profile is quite smooth. Consequently, the noise is intact and the signal-to-noise ratio is reduced in the projection image after scatter correction, leading to image artifacts and increased noise in the reconstruction images. We propose a simple and effective method, referred to as filtered scatter-to-primary ratio (f -SPR) estimation, to estimate the scatter profile using the sparsely sampled scatter signal. Using the primary sampling device and the stationary digital tomosynthesis systems previously developed in our lab, we evaluated and compared the f-SPR method in comparison with existing methods in terms of contrast ratio, signal difference-to-noise ratio, and modulation transfer function. A significant improvement in image quality is observed in both the projection and the reconstruction images using the proposed method

    Dynamic radiography using a carbon-nanotube-based field-emission x-ray source

    Get PDF
    We report a dynamic radiography system with a carbon nanotube based field-emission microfocus x-ray source. The system can readily generate x-ray radiation with continuous variation of temporal resolution as short as nanoseconds. Its potential applications for dynamic x-ray imaging are demonstrated. The performance characteristics of this compact and versatile system are promising for noninvasive imaging in biomedical research and industrial inspection

    Stationary scanning x-ray source based on carbon nanotube field emitters

    Get PDF
    We report a field emission x-ray source that can generate a scanning x-ray beam to image an object from multiple projection angles without mechanical motion. The key component of the device is a gated carbon nanotube field emission cathode with an array of electron emitting pixels that are individually addressable via a metal-oxide-semiconductor field effect transistor-based electronic circuit. The characteristics of this x-ray source are measured and its imaging capability is demonstrated. The device can potentially lead to a fast data acquisition rate for laminography and tomosynthesis with a simplified experimental setup

    Immune-mediated effects of microplanar radiotherapy with a small animal irradiator

    Get PDF
    Spatially fractionated radiotherapy has been shown to have effects on the immune system that differ from conventional radiotherapy (CRT). We compared several aspects of the immune response to CRT relative to a model of spatially fractionated radiotherapy (RT), termed microplanar radiotherapy (MRT). MRT delivers hundreds of grays of radiation in submillimeter beams (peak), separated by non-radiated volumes (valley). We have developed a preclinical method to apply MRT by a commercial small animal irradiator. Using a B16-F10 murine melanoma model, we first evaluated the in vitro and in vivo effect of MRT, which demonstrated significant treatment superiority relative to CRT. Interestingly, we observed insignificant treatment responses when MRT was applied to Rag−/− and CD8-depleted mice. An immuno-histological analysis showed that MRT recruited cytotoxic lymphocytes (CD8), while suppressing the number of regulatory T cells (Tregs). Using RT-qPCR, we observed that, compared to CRT, MRT, up to the dose that we applied, significantly increased and did not saturate CXCL9 expression, a cytokine that plays a crucial role in the attraction of activated T cells. Finally, MRT combined with anti-CTLA-4 ablated the tumor in half of the cases, and induced prolonged systemic antitumor immunity

    Visualizing microcalcifications in lumpectomy specimens: An exploration into the clinical potential of carbon nanotube-enabled stationary digital breast tomosynthesis

    Get PDF
    Purpose: To assess the visibility of microcalcifications in images generated by a first-generation carbon-nanotube (CNT)-enabled stationary digital breast tomosynthesis (sDBT) device, using magnified 2D mammography and conventional, moving-source DBT as references for comparison. Methods: Lumpectomy specimens were imaged by magnified mammography and two 3D mammography approaches, including sDBT and moving-source DBT. The planar size of individual microcalcifications was measured in the reconstructed image stacks of sDBT and moving-source DBT and compared to the magnified mammography image. An artifact spread function (ASF) was used to assess the depth dimensions of the microcalcifications displayed through the reconstructed image stacks. Breast-imaging specialists rated their preference for one imaging modality over another when interpreting microcalcifications in the magnified mammography image and synthetic slab images from sDBT and moving-source DBT. Results: The planar size of individual microcalcifications was similar in images generated by sDBT and moving-source DBT when the sDBT projections were binned to match the pixel size used by the moving-source DBT system. However, the unique structure of sDBT allowed for a wider-angle span of projection views and operation of the detector in full-resolution mode without significantly compromising the scan time. In this configuration, the planar sizes of individual microcalcifications displayed by sDBT was more similar to magnified mammography than moving-source DBT, and the microcalcifications had a narrower ASF through depth. Readers preferred sDBT over moving-source DBT when assessing microcalcifications in synthetic slab images, although magnified mammography was rated highest overall. Conclusions: The sDBT system displayed microcalcifications as well as conventional, moving-source DBT when the effective pixel size of the detector was matched. However, with the detector in its full-resolution mode, sDBT displayed microcalcifications with greater clarity. Readers still preferred images generated by magnified mammography over both 3D mammography approaches. This finding is guiding continued hardware and software development to optimize the sDBT technology
    • …