23 research outputs found

    Single-tube on-beam quartz-enhanced photoacoustic spectroscopy.

    Get PDF
    Quartz-enhanced photoacoustic spectroscopy (QEPAS) with a single-tube acoustic microresonator (AmR) inserted between the prongs of a custom quartz tuning fork (QTF) was developed, investigated, and optimized experimentally. Due to the high acoustic coupling efficiency between the AmR and the QTF, the single-tube on-beam QEPAS spectrophone configuration improves the detection sensitivity by 2 orders of magnitude compared to a bare QTF. This approach significantly reduces the spectrophone size with respect to the traditional on-beam spectrophone configuration, thereby facilitating the laser beam alignment. A 1σ normalized noise equivalent absorption coefficient of 1.21×10(-8) cm(-1)·W/√Hz was obtained for dry CO2 detection at normal atmospheric pressure

    Quartz enhanced photoacoustic H2S gas sensor based on a fiber-amplifier source and a custom tuning fork with large prong spacing

    Get PDF
    A quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplified laser source and a custom quartz tuning fork (QTF) with its two prongs spaced ∼800 μm apart, is reported. The sensor employs an acoustic micro-resonator (AmR) which is assembled in an “on-beam” QEPAS configuration. Both length and vertical position of the AmR are optimized in terms of signal-to-noise ratio, significantly improving the QEPAS detection sensitivity by a factor of ∼40, compared to the case of a sensor using a bare custom QTF. The fiber-amplifier-enhanced QEPAS sensor is applied to H2S trace gas detection, reaching a sensitivity of ∼890 ppb at 1 s integration time, similar to those obtained with a power-enhanced QEPAS sensor equipped with a standard QTF, but with the advantages of easy optical alignment, simple installation, and long-term stability

    Highly sensitive and selective CO sensor using a 2.33 μm diode laser and wavelength modulation spectroscopy

    Get PDF
    A ppm-level CO sensor based on a 2f wavelength modulation spectroscopy (2f-WMS) technique was developed for the application of SF6 decomposition analysis in an electric power system. A detailed investigation of the optimum target line selection was carried out to avoid spectral interference from high purity SF6 in a wide wavelength range. A diode laser emitting at 2.33 μm and a 14.5-m multipass gas cell (MGC) was employed to target the R(6) line of the CO first overtone band and increase the optical path, respectively, thus resulting in a minimum detection sensitivity of 1 ppm. A Levenberg-Marquardt nonlinear least-squares fit algorithm makes full use of the information from all data points of the 2f spectrum and as a result, a measurement precision of ~40 ppb was achieved with a data update rate of 0.6 s. The sensor performance was also evaluated in terms of the gas flow rate, stability, and linearity. The results showed that the best operating condition with a precision of 6 ppb can be achieved by increasing the gas flow rate to the value that matches the optimum averaging time of 48 s

    Simultaneous dual-gas QEPAS detection based on a fundamental and overtone combined vibration of quartz tuning fork

    Get PDF
    A dual-gas quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor system based on a frequency division multiplexing technique of a quartz tuning fork (QTF) was developed and experimentally demonstrated. Two beams from two independently modulated lasers are focused at two different positions between the QTF prongs to excite both the QTF fundamental and 1st overtone flexural modes simultaneously. The 2f-wavelength modulation technique is employed by applying two sinusoidal dithers, whose frequencies are equal to a half of the QTF fundamental and 1st overtone frequencies, respectively, to the currents of two excitation lasers. The resonance frequency difference between two flexural modes ensures that the correlated photoacoustic signals generated by different target gases do not interfere with each other. The proposed QEPAS methodology realizes a continuous real-time dual-gas monitoring with a simple setup and small sensor size compared with previous multi-gas QEPAS sensors

    Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring

    Get PDF
    Quartz-enhanced photoacoustic spectroscopy (QEPAS) is a sensitive gas detection technique which requires frequent calibration and has a long response time. Here we report beat frequency (BF) QEPAS that can be used for ultra-sensitive calibration-free trace-gas detection and fast spectral scan applications. The resonance frequency and Q-factor of the quartz tuning fork (QTF) as well as the trace-gas concentration can be obtained simultaneously by detecting the beat frequency signal generated when the transient response signal of the QTF is demodulated at its non-resonance frequency. Hence, BF-QEPAS avoids a calibration process and permits continuous monitoring of a targeted trace gas. Three semiconductor lasers were selected as the excitation source to verify the performance of the BF-QEPAS technique. The BF-QEPAS method is capable of measuring lower trace-gas concentration levels with shorter averaging times as compared to conventional PAS and QEPAS techniques and determines the electrical QTF parameters precisely

    Quartz-enhanced conductance spectroscopy for nanomechanical analysis of polymer wire

    Get PDF
    Quartz-enhanced conductance spectroscopy is developed as an analytical tool to investigate dynamic nanomechanical behaviors of polymer wires, in order to determine the glass transition temperature (Tg). A polymethyl methacrylate (PMMA) microwire with a diameter of 10 μm was bridged across the prongs of a quartz tuning fork (QTF). With the advantage of QTF self-sensing as compared with micro-cantilevers or other resonators, the resonance frequency and Q factor can be directly determined by means of its electrical conductance spectra with respect to the frequency of the external excitation source (dI/dV vs f), and therefore, no optical beam is required. The Tg of the PMMA microwire was determined by the maximum loss modulus of the QTF, calculated from the resonance frequency and the Q factor as a function of temperature. The measured Tg of the PMMA is 103 °C with an error of ±2 °C. Both heating/cooling and physical aging experiments were carried out, demonstrating that the technique is both reversible and reproducible

    Multi-Quartz Enhanced Photoacoustic Spectroscopy with Different Acoustic Microresonator Configurations

    No full text
    Acoustic microresonators were added to the recently developed multi-QTF based QEPAS spectrophone to enhance the signal amplitude. Two kinds of “on-beam” configurations were experimentally investigated in detail. The developed multi-QTF based “on-beam” spectrophone had a signal enhancement of 1.6 times compared with the traditional single QTF based “on-beam” spectrophone, with the approximate noise level. A normalized noise equivalent absorption coefficient (1σ) of 1.24 × 10−9 W·cm−1·Hz−1/2 was obtained for water vapor detection at atmospheric pressure

    Fiber-Amplifier-Enhanced QEPAS Sensor for Simultaneous Trace Gas Detection of NH3 and H2S

    No full text
    A selective and sensitive quartz enhanced photoacoustic spectroscopy (QEPAS) sensor, employing an erbium-doped fiber amplifier (EDFA), and a distributed feedback (DFB) laser operating at 1582 nm was demonstrated for simultaneous detection of ammonia (NH3) and hydrogen sulfide (H2S). Two interference-free absorption lines located at 6322.45 cm−1 and 6328.88 cm−1 for NH3 and H2S detection, respectively, were identified. The sensor was optimized in terms of current modulation depth for both of the two target gases. An electrical modulation cancellation unit was equipped to suppress the background noise caused by the stray light. An Allan-Werle variance analysis was performed to investigate the long-term performance of the fiber-amplifier-enhanced QEPAS sensor. Benefitting from the high power boosted by the EDFA, a detection sensitivity (1σ) of 52 parts per billion by volume (ppbv) and 17 ppbv for NH3 and H2S, respectively, were achieved with a 132 s data acquisition time at atmospheric pressure and room temperature

    Overtone resonance enhanced single-tube on-beam quartz enhanced photoacoustic spectrophone

    Get PDF
    A single-tube on-beam quartz enhanced photoacoustic spectroscopy (SO-QEPAS) spectrophone, which employs a custom-made quartz tuning fork (QTF) having a prong spacing of 700 μm and operating at the 1st overtone flexural mode, is reported. The design of QTF prong geometry allows the bare QTF to possess twice higher Q-factor values for the 1st overtone resonance mode falling at ∼17.7 kHz than in the fundamental resonance mode at ∼2.8 kHz, resulting in an 8 times higher QEPAS signal amplitude when operating in the 1st overtone resonance mode. Both the vertical position and length of the single-tube acoustic micro-resonator (AmR) were optimized to attain optimal spectrophone performance. Benefiting from the high overtone resonance frequency and the quasi 1st harmonic acoustic standing waves generated in the SO-QEPAS configuration, the AmR length is reduced to 14.5 mm. This allows the realization of compact spectrophone and facilitates the laser beam alignment through the QTF + AmR system. The signal enhancement in the overtone resonance mode and the high acoustic coupling efficiency between the AmR and QTF in the SO-QEPAS configuration yields an overall sensitivity enhancement factor of ∼380 with respect to the bare custom QTF operating in the fundamental resonance mode

    Ppb-level H2S detection for SF6 decomposition based on a fiber-amplified telecommunication diode laser and a background-gas-induced high-Q photoacoustic cell

    No full text
    A ppb-level hydrogen sulfide (H2S) gas sensor for sulfur hexafluoride (SF6) decomposition analysis was developed by means of a background-gas-induced high-Q differential photoacoustic cell (PAC) and a fiber-amplified telecommunication diode laser. The watt-level excitation laser power compensates the sensitivity loss as a result of using a low cost, near-IR laser source. The differential design with a large cylindrical resonator diameter allows the PAC to accommodate the high power beam and maintain a low noise level output. The theory of background-gas-induced high-Q PAC is provided and was verified experimentally. A H2S detection limit (1σ) of 109 ppb in a SF6 buffer gas was achieved for an averaging time of 1 s, which corresponds to a normalized noise equivalent absorption coefficient of 2.9 × 10−9 cm−1 W Hz−1/2
    corecore