5 research outputs found

    An investigation of putative hybridization between Calochortus selwayensis and Calochortus apiculatus (Liliaceae)

    Get PDF

    The influence of noise on image quality in phase-diverse coherent diffraction imaging

    No full text
    Phase-diverse coherent diffraction imaging provides a route to high sensitivity and resolution with low radiation dose. To take full advantage of this, the characteristics and tolerable limits of measurement noise for high quality images must be understood. In this work we show the artefacts that manifest in images recovered from simulated data with noise of various characteristics in the illumination and diffraction pattern. We explore the limits at which images of acceptable quality can be obtained and suggest qualitative guidelines that would allow for faster data acquisition and minimize radiation dose

    LaBr3(Ce):LaCl3(Ce) Phoswich with pulse shape analysis for high energy gamma-ray and proton identification

    No full text
    A novel Phoswich design based on new generation scintillator crystals is presented. The detector composed from a combination of a LaBr3(Ce) with a LaCl3(Ce) crystal in one cylinder coupled to a photo multiplier tube has been tested both for incident gamma rays in the range of 0.3–6 MeV, as well as for high energy protons in the range 120–180 MeV. The Phoswich assembly has not significantly deteriorated the energy resolution, which for 662 KeV gamma rays gives a resolution of 4.5%, while for high energy protons (Ep=180 MeV) an energy resolution of 1% was obtained. It is shown that the signals from the two crystals can be separated in an event by event based mode. Using direct digitizing of the detector pulse an off-line pulse-shape analysis was performed built either on a total to tail or total to pulse height method in order to fully identify the incoming radiation. Our aim with this R&D is to in the future build a detector which is able to detect with good efficiency and resolution over a wide energy range; 0.1–30 MeV gamma rays and 20–400 MeV protons. Monte Carlo simulations made in order to design the next prototype are presented

    Phoswich scintillator for proton and gamma radiation of high energy

    No full text
    We present here a Phoswich scintillator design to achieve both high resolution gamma ray detection, and good efficiency for high energy protons. There are recent developments of new high resolution scintillator materials. Especially the LaBr3(Ce) and LaCl3(Ce) crystals have very good energy resolution in the order of 3% for 662 keV gamma radiation. In addition, these materials exhibit a very good light output (63 and 32 photons/keV respectively). A demonstrator detector in the form of an Al cylinder of 24 mm diameter and a total length of 80 mm with 2 mm wall thickness, containing a LaBr3(Ce) crystal of 20 mm diameter and 30 mm length directly coupled to a LaCl3(Ce) crystal of 50 mm length, and closed with a glass window of 5 mm, was delivered by Saint Gobain. To the glass window a Hamamatsu R5380 Photomultiplier tube (PMT) was coupled using silicon optical grease. \ua9 2011 American Institute of Physics

    Bacteraemia in man and animals: An overview

    No full text
    corecore