192 research outputs found
Precision assessment of bowel motion quantification using 3D cine-MRI for radiotherapy
Objective. The bowel is an important organ at risk for toxicity during pelvic and abdominal radiotherapy. Identifying regions of high and low bowel motion with MRI during radiotherapy may help to understand the development of bowel toxicity, but the acquisition time of MRI is rather long. The aim of this study is to retrospectively evaluate the precision of bowel motion quantification and to estimate the minimum MRI acquisition time. Approach. We included 22 gynaecologic cancer patients receiving definitive radiotherapy with curative intent. The 10 min pre-treatment 3D cine-MRI scan consisted of 160 dynamics with an acquisition time of 3.7 s per volume. Deformable registration of consecutive images generated 159 deformation vector fields (DVFs). We defined two motion metrics, the 50th percentile vector lengths (VL50) of the complete set of DVFs was used to measure median bowel motion. The 95th percentile vector lengths (VL95) was used to quantify high motion of the bowel. The precision of these metrics was assessed by calculating their variation (interquartile range) in three different time frames, defined as subsets of 40, 80, and 120 consecutive images, corresponding to acquisition times of 2.5, 5.0, and 7.5 min, respectively. Main results. For the full 10 min scan, the minimum motion per frame of 50% of the bowel volume (M50%) ranged from 0.6-3.5 mm for the VL50 motion metric and 2.3-9.0 mm for the VL95 motion metric, across all patients. At 7.5 min scan time, the variation in M50% was less than 0.5 mm in 100% (VL50) and 95% (VL95) of the subsets. A scan time of 5.0 and 2.5 min achieved a variation within 0.5 mm in 95.2%/81% and 85.7%/57.1% of the subsets, respectively. Significance. Our 3D cine-MRI technique quantifies bowel loop motion with 95%-100% confidence with a precision of 0.5 mm variation or less, using a 7.5 min scan time.</p
Dynamic Collective Entity Representations for Entity Ranking
Entity ranking, i.e., successfully positioning a relevant entity at the top of the ranking for a given query, is inherently difficult due to the potential mismatch between the entity's description in a knowledge base, and the way people refer to the entity when searching for it. To counter this issue we propose a method for constructing dynamic collective entity representations. We collect entity descriptions from a variety of sources and combine them into a single entity representation by learning to weight the content from different sources that are associated with an entity for optimal retrieval effectiveness. Our method is able to add new descriptions in real time and learn the best representation as time evolves so as to capture the dynamics of how people search entities. Incorporating dynamic description sources into dynamic collective entity representations improves retrieval effectiveness by 7% over a state-of-the-art learning to rank baseline. Periodic retraining of the ranker enables higher ranking effectiveness for dynamic collective entity representations
The helium atom in a strong magnetic field
We investigate the electronic structure of the helium atom in a magnetic
field b etween B=0 and B=100a.u. The atom is treated as a nonrelativistic
system with two interactin g electrons and a fixed nucleus. Scaling laws are
provided connecting the fixed-nucleus Hamiltonia n to the one for the case of
finite nuclear mass. Respecting the symmetries of the electronic Ham iltonian
in the presence of a magnetic field, we represent this Hamiltonian as a matrix
with res pect to a two-particle basis composed of one-particle states of a
Gaussian basis set. The corresponding generalized eigenvalue problem is solved
numerically, providing in the present paper results for vanish ing magnetic
quantum number M=0 and even or odd z-parity, each for both singlet and triplet
spin symmetry. Total electronic energies of the ground state and the first few
excitations in each su bspace as well as their one-electron ionization energies
are presented as a function of the magnetic fie ld, and their behaviour is
discussed. Energy values for electromagnetic transitions within the M=0 sub
space are shown, and a complete table of wavelengths at all the detected
stationary points with respect to their field dependence is given, thereby
providing a basis for a comparison with observed ab sorption spectra of
magnetic white dwarfs.Comment: 21 pages, 4 Figures, acc.f.publ.in J.Phys.
Isotope shift in the electron affinity of chlorine
The specific mass shift in the electron affinity between ^{35}Cl and ^{37}Cl
has been determined by tunable laser photodetachment spectroscopy to be
-0.51(14) GHz. The isotope shift was observed as a difference in the onset of
the photodetachment process for the two isotopes. In addition, the electron
affinity of Cl was found to be 29138.59(22) cm^{-1}, giving a factor of 2
improvement in the accuracy over earlier measurements. Many-body calculations
including lowest-order correlation effects demonstrates the sensitivity of the
specific mass shift and show that the inclusion of higher-order correlation
effects would be necessary for a quantitative description.Comment: 16 pages, 6 figures, LaTeX2e, amsmat
Mixed configuration-interaction and many-body perturbation theory calculations of energies and oscillator strengths of J=1 odd states of neon
Ab-initio theory is developed for energies of J=1 particle-hole states of
neutral neon and for oscillator strengths of transitions from such states to
the J=0 ground state. Hole energies of low-Z neonlike ions are evaluated.Comment: 5 pages, 1 figure, 4 table
The dog as an animal model for DISH?
Diffuse idiopathic skeletal hyperostosis (DISH) is a systemic disorder of the axial and peripheral skeleton in humans and has incidentally been described in dogs. The aims of this retrospective radiographic cohort study were to determine the prevalence of DISH in an outpatient population of skeletally mature dogs and to investigate if dogs can be used as an animal model for DISH. The overall prevalence of canine DISH was 3.8% (78/2041). The prevalence of DISH increased with age and was more frequent in male dogs, similar to findings in human studies. In the Boxer breed the prevalence of DISH was 40.6% (28/69). Dog breeds represent closed gene pools with a high degree of familiar relationship and the high prevalence in the Boxer may be indicative of a genetic origin of DISH. It is concluded that the Boxer breed may serve as an animal model for DISH in humans
Diffuse idiopathic skeletal hyperostosis (DISH): relation to vertebral fractures and bone density
UnlabelledRadiographs and spinal bone mineral density (BMD) were evaluated from 342 elderly men regarding possible effects of diffuse idiopathic skeletal hyperostosis (DISH) on vertebral fractures and densitometry measurements. Prevalent vertebral fractures were more frequent among men with DISH compared to men with no DISH even after fracture prevalence was adjusted for BMD. Paravertebral calcifications should be considered in patients with DISH when interpreting BMD measurements because both dual X-ray absorptiometry (DXA) and quantitative CT (QCT) densitometry may not be reliable.IntroductionThe purpose of this study is to evaluate the prevalence of DISH in older men and its association with vertebral fractures and with BMD determined by DXA and QCT.MethodsLateral radiographs of the spine were analyzed in a sample of 342 men aged ≥ 65 years participating in the MrOS Study concerning the presence and grade of DISH and vertebral fractures. Lumbar BMD was measured by both DXA (areal, grams per square centimeter) and QCT (volumetric, grams per cubic centimeter). The association between DISH, BMD, and presence of fractures was studied using χ ( 2 ) and t tests.ResultsDISH was present in 52% (178/342) of the men. Men with DISH were older (mean, 75.1 vs 73.3, p < 0.05) and more likely to have prevalent fractures (28% vs 20%, p < p = 0.09). BMD assessed with DXA (1.08 vs 1.00 g/cm(2), p ≤ 0.0001), but not with QCT (0.11 vs 0.11 g/cm3, p = 0.65), was significantly higher in men with DISH compared to men without DISH. Significantly lower BMD of men with both DISH and fractures compared to men with DISH but without fractures was only detected by QCT (-25%, 0.09 vs 0.12, p < 0.05). Both DXA BMD and QCT BMD were significantly higher in severe lumbar DISH (+22% and +31%, p < 0.0001), respectively.ConclusionDISH was associated with a higher prevalence of vertebral fractures in elderly men. Lumbar ossifications related to DISH should be considered when interpreting BMD measurements to predict their fracture risk
An updated evaluation of the implementation of the sigmoid take-off landmark 1Â year after the official introduction in the Netherlands
- …