243 research outputs found

    Detection of Provasopressin in Invasive and Non-invasive (DCIS) Human Breast Cancer Using a Monoclonal Antibody Directed Against the C-terminus (MAG1)

    Get PDF
    The provasopressin protein (proAVP) is expressed by invasive breast cancer and non-invasive breast cancer, or ductal carcinoma in situ (DCIS). Here we demonstrate the ability of the monoclonal antibody MAG1 directed against the C-terminal end of proAVP to identify proAVP in all cases examined of human invasive cancer and DCIS (35 and 26, respectively). Tissues were chosen to represent a relevant variation in tumor type, grade, patient age, and menopausal status. By comparison, there was 65% positive staining for estrogen receptor, 61% for progesterone receptor, 67% for nuclear p53, and 39% for c-Erb-B2 with the invasive breast cancer sections. Reaction with the normal tissue types examined (67) was restricted to the vasopressinergic magnocellular neurons of the hypothalamus, where provasopressin is normally produced, and the posterior pituitary, where these neurons terminate. The breast epithelial tissue sections on the tissue microarray did not react with MAG1. Previously, we demonstrated that polyclonal antibodies to proAVP detected that protein in all breast cancer samples examined, but there was no reaction with breast tissue containing fibrocystic disease. The results presented here not only expand upon those earlier results, but they also demonstrate the specificity and effectiveness of what may be considered a more clinically-relevant agent. Thus, proAVP appears to be an attractive target for the detection of invasive breast cancer and DCIS, and these results suggest that MAG1 may be a beneficial tool for use in the development of such strategies

    Scanning in Situ Spectroscopy Pplatform for Imaging Surgical Breast Tissue Specimens

    Get PDF
    A non-contact localized spectroscopic imaging platform has been developed and optimized to scan 1 x 1 cm² square regions of surgically resected breast tissue specimens with ~150-micron resolution. A color corrected, image-space telecentric scanning design maintained a consistent sampling geometry and uniform spot size across the entire imaging field. Theoretical modeling in ZEMAX allowed estimation of the spot size, which is equal at both the center and extreme positions of the field with ~5% variation across the designed waveband, indicating excellent color correction. The spot sizes at the center and an extreme field position were also measured experimentally using the standard knife-edge technique and were found to be within ~8% of the theoretical predictions. Highly localized sampling offered inherent insensitivity to variations in background absorption allowing direct imaging of local scattering parameters, which was validated using a matrix of varying concentrations of Intralipid and blood in phantoms. Four representative, pathologically distinct lumpectomy tissue specimens were imaged, capturing natural variations in tissue scattering response within a given pathology. Variations as high as 60% were observed in the average reflectance and relative scattering power images, which must be taken into account for robust classification performance. Despite this variation, the preliminary data indicates discernible scatter power contrast between the benign vs malignant groups, but reliable discrimination of pathologies within these groups would require investigation into additional contrast mechanisms

    Micro-Computed Tomography Enables Rapid Surgical Margin Assessment During Breast Conserving Surgery (BCS): Correlation of Whole BCS Micro-CT Readings to Final Histopathology.

    Get PDF
    BACKGROUND: Roughly 23% of breast conserving surgery (BCS) patients undergo a second re-excision procedure due to pathologically positive surgical margins. We investigated the feasibility and potential value of micro-Computed Tomography (micro-CT) as a surgical margin guidance tool during BCS. METHODS: A cohort of 32 BCS specimens was prospectively imaged with a pre-clinical micro-CT system upon arrival in the surgical pathology laboratory. Reconstructed micro-CT scans were evaluated retrospectively by an experienced breast radiologist, who provided binary determinations whether lesions extended to the specimen margin. These readings were then compared to the final pathological diagnosis and to 2D specimen radiography readings. RESULTS: Of the 32 specimens imaged, 28 had malignant and four had benign pathological diagnoses. Overall five (four malignant, one benign) of the 32 specimens had lesion tissue extending to the margin. For all 32 specimens, micro-CT reconstructions were calculated (\u3c 4 min. acquisition + reconstruction time) and each specimen was volumetrically analyzed by a radiologist. Of the 28 malignant specimen readings, 18 matched the final pathological diagnosis [64%, 95 CI (47%-81%)], with a negative predictive value of 89% [95 CI (74%-96%)]. Micro-CT readings revealed changes in the tumor location and margin status as compared to single-projection radiography readings. CONCLUSIONS: Micro-CT scanning of BCS specimens enabled margin status assessment over the entirety of the surgical surface in a clinically relevant time frame, provided additional spatial information over single-projection radiography, and may be a potentially useful BCS guidance tool

    Developing diagnostic assessment of breast lumpectomy tissues using radiomic and optical signatures

    Get PDF
    High positive margin rates in oncologic breast-conserving surgery are a pressing clinical problem. Volumetric X-ray scanning is emerging as a powerful ex vivo specimen imaging technique for analyzing resection margins, but X-rays lack contrast between non-malignant and malignant fibrous tissues. In this study, combined micro-CT and wide-field optical image radiomics were developed to classify malignancy of breast cancer tissues, demonstrating that X-ray/optical radiomics improve malignancy classification. Ninety-two standardized features were extracted from co-registered micro-CT and optical spatial frequency domain imaging samples extracted from 54 breast tumors exhibiting seven tissue subtypes confirmed by microscopic histological analysis. Multimodal feature sets improved classification performance versus micro-CT alone when adipose samples were included (AUC = 0.88 vs. 0.90; p-value = 3.65e−11) and excluded, focusing the classification task on exclusively non-malignant fibrous versus malignant tissues (AUC = 0.78 vs. 0.85; p-value = 9.33e−14). Extending the radiomics approach to high-dimensional optical data—termed “optomics” in this study—offers a promising optical image analysis technique for cancer detection. Radiomic feature data and classification source code are publicly available

    Review of Methods for Intraoperative Margin Detection for Breast Conserving Surgery

    Get PDF
    Breast conserving surgery (BCS) is an effective treatment for early-stage cancers as long as the margins of the resected tissue are free of disease according to consensus guidelines for patient management. However, 15% to 35% of patients undergo a second surgery since malignant cells are found close to or at the margins of the original resection specimen. This review highlights imaging approaches being investigated to reduce the rate of positive margins, and they are reviewed with the assumption that a new system would need high sensitivity near 95% and specificity near 85%. The problem appears to be twofold. The first is for complete, fast surface scanning for cellular, structural, and/or molecular features of cancer, in a lumpectomy volume, which is variable in size, but can be large, irregular, and amorphous. A second is for full, volumetric imaging of the specimen at high spatial resolution, to better guide internal radiologic decision-making about the spiculations and duct tracks, which may inform that surfaces are involved. These two demands are not easily solved by a single tool. Optical methods that scan large surfaces quickly are needed with cellular/molecular sensitivity to solve the first problem, but volumetric imaging with high spatial resolution for soft tissues is largely outside of the optical realm and requires x-ray, micro-CT, or magnetic resonance imaging if they can be achieved efficiently. In summary, it appears that a combination of systems into hybrid platforms may be the optimal solution for these two very different problems. This concept must be cost-effective, image specimens within minutes and be coupled to decision-making tools that help a surgeon without adding to the procedure. The potential for optical systems to be involved in this problem is emerging and clinical trials are underway in several of these technologies to see if they could reduce positive margin rates in BCS

    Optical assessment of pathology in surgically resected tissues

    Get PDF
    Multi-spectral spatially modulated light is used to guide localized spectroscopy of surgically resected tissues for cancer involvement. Modulated imaging rapidly quantifies near-infrared optical parameters with sub-millimeter resolution over the entire field for identification of residual disease in resected tissues. Suspicious lesions are further evaluated using a spectroscopy platform designed to image thick tissue samples at a spatial resolution sensitive to the diagnostic gold standard, pathology. MI employs a spatial frequency domain sampling and model-based analysis of the spatial modulation transfer function to interpret a tissue's absorption and scattering parameters at depth. The spectroscopy platform employs a scanning-beam, telecentric dark-field illumination and confocal detection to image fields up to 1cm2 with a broadband source (480:750nm). The sampling spot size (100μm lateral resolution) confines the volume of tissue probed to within a few transport pathlengths so that multiple-scattering effects are minimized and simple empirical models may be used to analyze spectra. Localized spectroscopy of Intralipid and hemoglobin phantoms demonstrate insensitivity of recovered scattering parameters to changes in absorption, but a non-linear dependence of scattering power on Intralipid concentration is observed due to the phase sensitivity of the measurement system. Both systems were validated independently in phantom and murine studies. Ongoing work focuses on assessing the combined utility of these systems to identify cancer involvement in vitro, particularly in the margins of resected breast tumors

    Structured Light Scatteroscopy

    Get PDF
    A new imaging approach, structured light scatteroscopy (SLS), is demonstrated, which offers rapid wide-field imaging of microscopic morphological variations in bulk tissue surfaces. Elastic scattering of light offers exquisite sensitivity to ultrastructural changes at multiple size scales ranging from nanometers to millimeters, but in bulk tissues the confounding effects of molecular absorption and strong multiple scattering of light often lead to a dramatic reduction in scatter contrast and specificity. It is demonstrated that the SLS using structured high spatial frequency illumination and detection to probe the tissue achieves direct, absorption-independent, high-resolution maps of the scattering response. The scattering response is observed to be dependent on both the wavelength and spatial frequency of choice, indicating a potential for multiscale probing of ultrastructural changes in superficial tissue layers. This methodology can be easily applied in most wide-field imaging systems

    Light Scattering Measured with Spatial Frequency Domain Imaging can Predict Stromal Versus Epithelial Proportions in Surgically Resected Breast Tissue

    Get PDF
    This study aims to determine if light scatter parameters measured with spatial frequency domain imaging (SFDI) can accurately predict stromal, epithelial, and adipose fractions in freshly resected, unstained human breast specimens. An explicit model was developed to predict stromal, epithelial, and adipose fractions as a function of light scattering parameters, which was validated against a quantitative analysis of digitized histology slides for N  =  31 specimens using leave-one-out cross-fold validation. Specimen mean stromal, epithelial, and adipose volume fractions predicted from light scattering parameters strongly correlated with those calculated from digitized histology slides (r  =  0.90, 0.77, and 0.91, respectively, p-value×  10  -  6). Additionally, the ratio of predicted epithelium to stroma classified malignant specimens with a sensitivity and specificity of 90% and 81%, respectively, and also classified all pixels in malignant lesions with 63% and 79%, at a threshold of 1. All specimens and pixels were classified as malignant, benign, or fat with 84% and 75% accuracy, respectively. These findings demonstrate how light scattering parameters acquired with SFDI can be used to accurately predict and spatially map stromal, epithelial, and adipose proportions in fresh unstained, human breast tissue, and suggest that these estimations could provide diagnostic value

    Calibration and Analysis of a Multimodal Micro-CT and Structured Light Imaging System for the Evaluation of Excised Breast Tissue.

    Get PDF
    A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast of 1.64, and a minimum detectable resolution of 240 ?m for a 1.2?min scan. The SLI system, spanning wavelengths 490?nm to 800?nm and spatial frequencies up to 1.37 , was evaluated with aqueous tissue simulating phantoms having variations in particle size distribution, scatter density, and blood volume fraction. The reduced scattering coefficient, and phase function parameter, ?, were accurately recovered over all wavelengths independent of blood volume fractions from 0% to 4%, assuming a flat sample geometry perpendicular to the imaging plane. The resolution of the optical system was tested with a step phantom, from which the modulation transfer function was calculated yielding a maximum resolution of 3.78 cycles per mm. The three dimensional spatial co-registration between the CT and optical imaging space was tested and shown to be accurate within 0.7?mm. A freshly resected breast specimen, with lobular carcinoma, fibrocystic disease, and adipose, was imaged with the system. The micro-CT provided visualization of the tumor mass and its spiculations, and SLI yielded superficial quantification of light scattering parameters for the malignant and benign tissue types. These results appear to be the first demonstration of SLI combined with standard medical tomography for imaging excised tumor specimens. While further investigations are needed to determine and test the spectral, spatial, and CT features required to classify tissue, this study demonstrates the ability of multimodal CT/SLI to quantify, visualize, and spatially navigate breast tumor specimens, which could potentially aid in the assessment of tumor margin status during BCS

    Near-Infrared Characterization of Breast Tumors In Vivo using Spectrally-Constrained Reconstruction

    Get PDF
    Multi-wavelength Near-Infrared (NIR) Tomography was utilized in this study to non-invasively quantify physiological parameters of breast tumors using direct spectral reconstruction. Frequency domain NIR measurements were incorporated with a new spectrally constrained direct chromophore and scattering image reconstruction algorithm, which was validated in simulations and experimental phantoms. Images of total hemoglobin, oxygen saturation, water, and scatter parameters were obtained with higher accuracy than previously reported. Using this spectral approach, in vivo NIR images are presented and interpreted through a series of case studies (n=6 subjects) having differing abnormalities. The corresponding mammograms and ultrasound images are also evaluated. Three of six cases were malignant (infiltrating ductal carcinomas) and showed higher hemoglobin (34–86% increase), a reduction in oxygen saturation, an increase in water content as well as scatter changes relative to surrounding normal tissue. Three of six cases were benign, two of which were diagnosed with fibrocystic disease and showed a dominant contrast in water, consistent with fluid filled cysts. Scatter amplitude was the main source of contrast in the volunteer with the benign condition fibrosis, which typically contains denser collagen tissue. The changes monitored correspond to physiological changes associated with angiogenesis, hypoxia and cell proliferation anticipated in cancers. These changes represent potential diagnostic indicators, which can be assessed to characterize breast tumors
    corecore