45 research outputs found

    The Effects of Concentric Ring Electrode Electrical Stimulation on Rat Skin

    Get PDF
    Surface electrodes are commonly used electrodes clinically, in applications such as functional electrical stimulation for the restoration of motor functions, pain relief, transcutaneous electrical nerve stimulation, electrocardiographic monitoring, defibrillation, surface cardiac pacing, and advanced drug delivery systems. Common to these applications are occasional reports of pain, tissue damage, rash, or burns on the skin at the point where electrodes are placed. In this study, we quantitatively analyzed the effects of acute noninvasive electrical stimulation from concentric ring electrodes (CRE) to determine the maximum safe current limit. We developed a three-dimensional multi-layer model and calculated the temperature profile under the CRE and the corresponding energy density with electrical-thermal coupled field analysis. Infrared thermography was used to measure skin temperature during electrical stimulation to verify the computer simulations. We also performed histological analysis to study cell morphology and characterize any resulting tissue damage. The simulation results are accurate for low energy density distributions. It can also be concluded that as long as the specified energy density applied is kept below 0.92 (A2/cm4·s−1), the maximum temperature will remain within the safe limits. Future work should focus on the effects of the electrode paste

    Automatic Seizure Detection in Rats Using Laplacian EEG and Verification with Human Seizure Signals

    Get PDF
    Automated detection of seizures is still a challenging problem. This study presents an approach to detect seizure segments in Laplacian electroencephalography (tEEG) recorded from rats using the tripolar concentric ring electrode (TCRE) configuration. Three features, namely, median absolute deviation, approximate entropy, and maximum singular value were calculated and used as inputs into two different classifiers: support vector machines and adaptive boosting. The relative performance of the extracted features on TCRE tEEG was examined. Results are obtained with an overall accuracy between 84.81 and 96.51%. In addition to using TCRE tEEG data, the seizure detection algorithm was also applied to the recorded EEG signals from Andrzejak et al. database to show the efficiency of the proposed method for seizure detection

    WearLight: Towards a Wearable, Configurable Functional NIR Spectroscopy System for Noninvasive Neuroimaging

    Get PDF
    Functional near-infrared spectroscopy (fNIRS) has emerged as an effective brain monitoring technique to measure the hemodynamic response of the cortical surface. Its wide popularity and adoption in recent time attribute to its portability, ease of use, and flexibility in multimodal studies involving electroencephalography. While fNIRS is still emerging on various fronts including hardware, software, algorithm, and applications, it still requires overcoming several scientific challenges associated with brain monitoring in naturalistic environments where the human participants are allowed to move and required to perform various tasks stimulating brain behaviors. In response to these challenges and demands, we have developed a wearable fNIRS system, WearLight that was built upon an Internet-of-Things embedded architecture for onboard intelligence, configurability, and data transmission. In addition, we have pursued detailed research and comparative analysis on the design of the optodes encapsulating an near-infrared light source and a detector into 3-D printed material. We performed rigorous experimental studies on human participants to test reliability, signal-to-noise ratio, and configurability. Most importantly, we observed that WearLight has a capacity to measure hemodynamic responses in various setups including arterial occlusion on the forearm and frontal lobe brain activity during breathing exercises in a naturalistic environment. Our promising experimental results provide an evidence of preliminary clinical validation of WearLight. This encourages us to move toward intensive studies involving brain monitoring

    Effects of transcranial focal electrical stimulation via tripolar concentric ring electrodes on pentylenetetrazole-induced seizures in rats

    Get PDF
    Purpose: To study the effects of noninvasive transcranial focal electrical stimulation (TFS) via tripolar concentric ring electrodes (TCRE) on the electrographic and behavioral activity from pentylenetetrazole (PTZ)-induced seizures in rats. Methods: The TCREs were attached to the rat scalp. PTZ was administered and, after the first myoclonic jerk was observed, TFS was applied to the TFS treated group. The electroencephalogram (EEG) and behavioral activity were recorded and studied. Results: In the case of the TFS treated group, after TFS, there was a significant (p = 0.001) decrease in power compared to the control group in delta, theta, and alpha frequency bands. The number of myoclonic jerks was significantly different (p = 0.002) with median of 22 and 4.5 for the control group and the TFS treated groups, respectively. The duration of myoclonic activity was also significantly different (p = 0.031) with median of 17.56 min for the control group versus 8.63 min for the TFS treated group. At the same time there was no significant difference in seizure onset latency and maximal behavioral seizure activity score between control and TFS treated groups. Conclusions: TFS via TCREs interrupted PTZ-induced seizures and electrographic activity was reduced toward the “baseline.” The significantly reduced electrographic power, number of myoclonic jerks, and duration of myoclonic activity of PTZ-induced seizures suggests that TFS may have an anticonvulsant effect

    Automatic food intake detection based on swallowing sounds

    Get PDF
    This paper presents a novel fully automatic food intake detection methodology, an important step toward objective monitoring of ingestive behavior. The aim of such monitoring is to improve our understanding of eating behaviors associated with obesity and eating disorders. The proposed methodology consists of two stages. First, acoustic detection of swallowing instances based on mel-scale Fourier spectrum features and classification using support vector machines is performed. Principal component analysis and a smoothing algorithm are used to improve swallowing detection accuracy. Second, the frequency of swallowing is used as a predictor for detection of food intake episodes. The proposed methodology was tested on data collected from 12 subjects with various degrees of adiposity. Average accuracies of \u3e80% and \u3e75% were obtained for intra-subject and inter-subject models correspondingly with a temporal resolution of 30 s. Results obtained on 44.1 h of data with a total of 7305 swallows show that detection accuracies are comparable for obese and lean subjects. They also suggest feasibility of food intake detection based on swallowing sounds and potential of the proposed methodology for automatic monitoring of ingestive behavior. Based on a wearable non-invasive acoustic sensor the proposed methodology may potentially be used in free-living conditions

    Transcranial focal electrical stimulation via tripolar concentric ring electrodes does not modify the short- and long-term memory formation in rats evaluated in the novel object recognition test

    Get PDF
    Noninvasive transcranial focal electrical stimulation (TFS) via tripolar concentric ring electrodes (TCREs) has been under development as an alternative/complementary therapy for seizure control. Transcranial focal electrical stimulation has shown efficacy in attenuating penicillin-, pilocarpine-, and pentylenetetrazole-induced acute seizures in rat models. This study evaluated the effects of TFS via TCREs on the memory formation of healthy rats as a safety test of TFS. Short- and long-term memory formation was tested after the application of TFS using the novel object recognition (NOR) test. The following independent groups were used: naïve, control (without TFS), and TFS (treated). The naïve, control, and stimulated groups spent more time investigating the new object than the familiar one during the test phase. Transcranial focal electrical stimulation via TCREs given once does not modify the short- and long-term memory formation in rats in the NOR test. Results provide an important step towards a better understanding for the safe usage of TFS via TCREs

    Noninvasive Transcranial Focal Stimulation Via Tripolar Concentric Ring Electrodes Lessens Behavioral Seizure Activity of Recurrent Pentylenetetrazole Administrations in Rats

    Get PDF
    Epilepsy affects approximately 1% of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We have been developing a noninvasive transcranial focal electrical stimulation with our novel tripolar concentric ring electrodes as an alternative/complementary therapy for seizure control. In this study we demonstrate the effect of focal stimulation on behavioral seizure activity induced by two successive pentylenetetrazole administrations in rats. Seizure onset latency, time of the first behavioral change, duration of seizure, and maximal seizure severity score were studied and compared for focal stimulation treated (n = 9) and control groups (n = 10). First, we demonstrate that no significant difference was found in behavioral activity for focal stimulation treated and control groups after the first pentylenetetrazole administration. Next, comparing first and second pentylenetetrazole administrations, we demonstrate there was a significant change in behavioral activity (time of the first behavioral change) in both groups that was not related to focal stimulation. Finally, we demonstrate focal stimulation provoking a significant change in seizure onset latency, duration of seizure, and maximal seizure severity score. We believe that these results, combined with our previous reports, suggest that transcranial focal stimulation may have an anticonvulsant effect

    Transcranial focal electrical stimulation via concentric ring electrodes in freely moving cats: Antiepileptogenic and postictal effects

    Get PDF
    Transcranial focal electrical stimulation (TFS) via tripolar concentric ring electrodes (TCRE), tripolar TFS, is proposed to treat pharmacoresistant epilepsy. We determined the effect of tripolar TFS on electrical amygdaloid kindling (AK) in freely moving cats. Fifteen cats were bilaterally implanted with electrodes in the amygdala (AM) and prefrontal cortex and assigned to three groups: the control group, which only received AK; the tripolar TFS before AK group, in which TCREs were placed over the vertex and tripolar TFS (300 Hz, 200 μs biphasic equal charge, square pulses) was delivered for 40 min just prior to AK; and the tripolar TFS after AK group, in which the TCREs were placed over the temporal bone ipsilateral to the kindled AM, while tripolar TFS was administered for 2 min just after AK onset for 40 days, and, thereafter, only AK was applied. AK was applied daily until all animals reached kindling stage VI. A three concentric spheres finite element cat head model was developed to analyze the electric fields caused by tripolar TFS. Tripolar TFS after AK inhibited kindling development. Animals with tripolar TFS after AK remained at the focal seizure stages for 20 days after tripolar TFS cessation and required 80.0 ± 15.42 AK stimulations to reach stage VI, significantly higher than TFS before AK, and control (P \u3c .001). Tripolar TFS before AK did not show signs of protection against epileptogenesis. The finite modeling of tripolar TFS showed that the electric field is \u3e0.3 mV/mm at depths less than approximately 12.6 mm in the cat brain, which should be strong enough to alter brain activity. In conclusion, tripolar TFS applied via a TCRE over the ipsilateral temporal area significantly delayed AK. This taken together with other reports of tripolar TFS aborting seizures in acute seizure models suggests that tripolar TFS is a promising new modality that should be considered for further testing

    High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes

    Get PDF
    Epilepsy is the second most prevalent neurological disorder (~1% prevalence) affecting ~67 million people worldwide with up to 75% from developing countries. The conventional electroencephalogram is plagued with artifacts from movements, muscles, and other sources. Tripolar concentric ring electrodes automatically attenuate muscle artifacts and provide improved signal quality. We performed basic experiments in healthy humans to show that tripolar concentric ring electrodes can indeed record the physiological alpha waves while eyes are closed. We then conducted concurrent recordings with conventional disc electrodes and tripolar concentric ring electrodes from patients with epilepsy. We found that we could detect high frequency oscillations, a marker for early seizure development and epileptogenic zone, on the scalp surface that appeared to become more narrow-band just prior to seizures. High frequency oscillations preceding seizures were present in an average of 35.5% of tripolar concentric ring electrode data channels for all the patients with epilepsy whose seizures were recorded and absent in the corresponding conventional disc electrode data. An average of 78.2% of channels that contained high frequency oscillations were within the seizure onset or irritative zones determined independently by three epileptologists based on conventional disc electrode data and videos
    corecore